Armin Karcher

Armin Karcher

Auto-generated profile, based on publicly available information

Armin Karcher

Lawrence Berkeley National Laboratory, One Cyclotron Rd, Berkeley, CA 94720, USA

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2004 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JWJ.-P. Walder
J.-P. Walder
GCG. Chao
G. Chao
JGJ.-F. Genat
J.-F. Genat
AKA. Karcher
A. Karcher
BKB. Krieger
B. Krieger
HLH. von der Lippe
H. von der Lippe
A four-channel custom chip designed for reading out the CCDs of the proposed SNAP satellite visible imager is presented. Each channel consists of a single-ended to differential converter followed by a correlated double sampler and a novel multislope integrator. The output signal is differentially brought out of the chip by an output buffer. This circuit is designed to operate at room temperature for test purpose and at 140 K, which will be the operating temperature. The readout speed is 100 kHz. The 16-bit dynamic range is covered using 3 gains each with a 12-bit signal to noise ratio. The prototype chip, implemented in a 0.25 /spl mu/m CMOS technology, has a measured readout noise of 7 /spl mu/V rms at 100 kHz readout speed, a measured nonlinearity of /spl plusmn/0.0025% and a power consumption of 6.5 mW, with a 3.3 V supply voltage.

1 September 2024 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
KLKenneth W. Lin
Kenneth W. Lin
AKArmin Karcher
Armin Karcher
JGJulien Guy
Julien Guy
SHStephen E. Holland
Stephen E. Holland
WKWilliam F. Kolbe
William F. Kolbe
JTJavier Tiffenberg
Javier Tiffenberg
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e− rms pix−1 at a speed of 26 μs pix−1 with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e− was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

1 August 1999 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SDS.F. Dow
S.F. Dow
AKA. Karcher
A. Karcher
MLM.E. Levi
M.E. Levi
MMM. Momayezi
M. Momayezi
HLH. von der Lippe
H. von der Lippe
DAD. Ando
D. Ando

12 January 2004
Verified
Conference Paper
Open access
PDF file
CBC. J. Bebek
C. J. Bebek
JBJ. H. Bercovitz
J. H. Bercovitz
DGD. E. Groom
D. E. Groom
SHS. E. Holland
S. E. Holland
RKR. W. Kadel
R. W. Kadel
GWG. Wang
G. Wang
An overview of CCD development efforts at Lawrence Berkeley National Laboratory is presented. Operation of fully-depleted, back-illuminated CCD's fabricated on high resistivity silicon is described, along with results on the use of such CCD's at ground-based observatories. Radiation damage and point-spread function measurements are described, as well as discussion of CCD fabrication technologies.

1 August 1999 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ABA. Berenyi
A. Berenyi
HCH.K. Chen
H.K. Chen
KDK. Dao
K. Dao
SDS.F. Dow
S.F. Dow
SGStefan Gehrig
Stefan Gehrig
ARA. Romosan
A. Romosan

1 April 2025 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Open access
KLKenneth W. Lin
Kenneth W. Lin
ABAbby Bault
Abby Bault
AKArmin Karcher
Armin Karcher
JGJulien Guy
Julien Guy
SHStephen E. Holland
Stephen E. Holland
PNPeter E. Nugent
Peter E. Nugent
Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e− rms pix−1 at 19 μs pix−1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.