Ardavan Javid

Ardavan Javid

Auto-generated profile, based on publicly available information

Ardavan Javid

School of Electrical Engineering and Computer Science, Pennsylvania State University, University Park, PA, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
AJArdavan Javid
Ardavan Javid
SISheikh Ilham
Sheikh Ilham
MKMehdi Kiani
Mehdi Kiani
The invasiveness of neuromodulation technologies that require surgical implantation (e.g., electrical and optical stimulation) may limit their clinical application. Thus, alternative technologies that offer similar benefits without surgery are of paramount importance in the field of neuromodulation. Low-intensity ultrasound is an emerging modality for neural stimulation as ultrasound can be focused in deep tissues with millimeter resolution. Transcranial focused ultrasound stimulation (tFUS) has already been demonstrated in a wide range of animals and even humans at different sonication frequencies (mostly in the sub-MHz range due to the presence of the skull). This article first provides some fundamental knowledge in ultrasound, and then reviews various examples of successful tFUS experiments in animals and humans using different stimulation patterns, as well as available tFUS technologies for generating, focusing, and steering ultrasound beams in neural tissues. In particular, phased array technologies for the ultrasound stimulation application are discussed with an emphasis on the design, fabrication, and integration of ultrasound transducer arrays as well as the design and development of phased array electronics with beamformer and high-voltage driver circuitry. The challenges in tFUS, such as its underlying mechanism, indirect auditory response, and skull aberration effects, are also discussed.

1 December 2014
Verified
Conference Paper
Closed access
AJArdavan Javid
Ardavan Javid
HVHanif Vahedian
Hanif Vahedian
ASAmir M. Sodagar
Amir M. Sodagar
MMMehdi Ehsanian Mofrad
Mehdi Ehsanian Mofrad
A novel ultra-low power non-coherent BPSK demodulator for biomedical implants is presented. The proposed demodulation technique is based on utilizing a delayed and digitized form of the input signal for the detection of the received data and also for retrieving a synchronized clock signal. The BPSK demodulator circuit proposed in this work is capable of operating at a carrier frequency of 10 MHz with a data-rate-to-carrier-frequency (DRCF) of up to 100%. Designed and simulated in a 0.18-μm standard N-Well CMOS technology, the circuit consumes 27.2μW@1.8V. The proposed demodulation concept was also realized on a proof-of-concept prototype circuit board.