Sheikh Ilham

Mr. Sheikh Ilham

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
ZKZeinab Kashani
Zeinab Kashani
SISheikh Ilham
Sheikh Ilham
MKMehdi Kiani
Mehdi Kiani
Ultrasound (US) is an attractive modality for wireless power transfer (WPT) to biomedical implants with millimeter (mm) dimensions. To compensate for misalignments in WPT to a mm-sized implant (or powering a network of mm-sized implants), a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused US beams at different locations. This paper presents the theory and design methodology of US WPT links with phased arrays and mm-sized receivers (Rx). For given constraints imposed by the application and fabrication, such as load ( RL ) and focal distance ( F ), the optimal geometries of a US phased array and Rx transducer, as well as the optimal operation frequency ( fc ) are found through an iterative design procedure to maximize the power transfer efficiency (PTE). An optimal figure of merit (FoM) related to PTE is proposed to simplify the US array design. A design example of a US link is presented and optimized for WPT to a mm-sized Rx with a linear array. In measurements, the fabricated 16-element array (10.9×9×1.7 mm 3 ) driven by 100 V pulses at fc of 1.1 MHz with optimal delays for focusing at F = 20 mm generated a US beam with a pressure output of 0.8 MPa. The link could deliver up to 6 mW to a ∼ 1 mm 3 Rx with a PTE of 0.14% ( RL = 850 Ω). The beam steering capability of the array at -45 o to 45 o angles was also characterized.

3 May 2018 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
SISheikh Ilham
Sheikh Ilham
LCLongtu Chen
Longtu Chen
TGTiantian Guo
Tiantian Guo
SESharareh Emadi
Sharareh Emadi
KHKazunori Hoshino
Kazunori Hoshino
BFBin Feng
Bin Feng
Ultrasound that is widely used in medical diagnosis has drawn growing interests as a noninvasive means of neuromodulation. Focused pulsed ultrasound (FPUS) effectively modulates neural encoding and transmission in the peripheral nervous system (PNS) with unclear mechanism of action, which is further confounded by contradictory experimental outcomes from recordings of compound action potentials (CAP). To address that, we developed a novel in vitro set up to achieve simultaneous single-unit recordings from individual mouse sciatic nerve axon and systematically studied the neuromodulation effects of FPUS on individual axon. Unlike previous CAP recordings, our single-unit recordings afford superior spatial and temporal resolution to reveal the subtle but consistent effects of ultrasonic neuromodulation. Our results indicate that, (1) FPUS did not evoke action potentials directly in mouse sciatic nerve at all the tested intensities (spatial peak temporal average intensity, I SPTA of 0.91 to 28.2 W/cm 2 ); (2) FPUS increases the nerve conduction velocity (CV) in both fast-conducting A- and slow-conducting C- type axons with effects more pronounced at increased stimulus duration and intensity; and (3) effects of increased CV is reversible and cannot be attributed to the change of local temperature. Our results support existing theories of non-thermal mechanisms underlying ultrasonic neuromodulation with low-intensity FPUS, including NICE, flexoelectricity, and solition models. This work also provides a solid experimental basis to further advance our mechanistic understandings of ultrasonic neuromodulation in the PNS.

17 February 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
SISheikh Ilham
Sheikh Ilham
ZKZeinab Kashani
Zeinab Kashani
MKMehdi Kiani
Mehdi Kiani
Low-intensity transcranial focused ultrasound stimulation (tFUS), as a noninvasive neuromodulation modality, has shown to be effective in animals and even humans with improved millimeter-scale spatial resolution compared to its noninvasive counterparts. But conventional tFUS systems are built with bulky single-element ultrasound (US) transducers that must be mechanically moved to change the stimulation target. To achieve large-scale ultrasound neuromodulation (USN) within a given tissue volume, a US transducer array should electronically be driven in a beamforming fashion (known as US phased array) to steer focused ultrasound beams towards different neural targets. This paper presents the theory and design methodology of US phased arrays for USN at a large scale. For a given tissue volume and sonication frequency (f), the optimal geometry of a US phased array is found with an iterative design procedure that maximizes a figure of merit (FoM) and minimizes side/grating lobes (avoiding off-target stimulation). The proposed FoM provides a balance between the power efficiency and spatial resolution of a US array in USN. A design example of a US phased array has been presented for USN in a rat's brain with an optimized linear US array. In measurements, the fabricated US phased array with 16 elements (16.7×7.7×2 mm3), driven by 150 V (peak-peak) pulses at f = 833.3 kHz, could generate a focused US beam with a lateral resolution of 1.6 mm and pressure output of 1.15 MPa at a focal distance of 12 mm. The capability of the US phased array in beam steering and focusing from -60o to 60o angles was also verified in measurements.

19 April 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BFBin Feng
Bin Feng
LCLongtu Chen
Longtu Chen
SISheikh Ilham
Sheikh Ilham
Ultrasonic (US) neuromodulation has emerged as a promising therapeutic means by delivering focused energy deep into the nervous tissue. Low-intensity ultrasound (US) directly activates and/or inhibits neurons in the central nervous system (CNS). US neuromodulation of the peripheral nervous system (PNS) is less developed and rarely used clinically. The literature on the neuromodulatory effects of US on the PNS is controversial, with some studies documenting enhanced neural activities, some showing suppressed activities, and others reporting mixed effects. US, with different ranges of intensity and strength, is likely to generate distinct physical effects in the stimulated neuronal tissues, which underlies different experimental outcomes in the literature. In this review, we summarize all the major reports that document the effects of US on peripheral nerve endings, axons, and/or somata in the dorsal root ganglion. In particular, we thoroughly discuss the potential impacts of the following key parameters on the study outcomes of PNS neuromodulation by US: frequency, pulse repetition frequency, duty cycle, intensity, metrics for peripheral neural activities, and type of biological preparations used in the studies. Potential mechanisms of peripheral US neuromodulation are summarized to provide a plausible interpretation of the seemly contradictory effects of enhanced and suppressed neural activities of US neuromodulation.

28 July 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
AJArdavan Javid
Ardavan Javid
SISheikh Ilham
Sheikh Ilham
MKMehdi Kiani
Mehdi Kiani
The invasiveness of neuromodulation technologies that require surgical implantation (e.g., electrical and optical stimulation) may limit their clinical application. Thus, alternative technologies that offer similar benefits without surgery are of paramount importance in the field of neuromodulation. Low-intensity ultrasound is an emerging modality for neural stimulation as ultrasound can be focused in deep tissues with millimeter resolution. Transcranial focused ultrasound stimulation (tFUS) has already been demonstrated in a wide range of animals and even humans at different sonication frequencies (mostly in the sub-MHz range due to the presence of the skull). This article first provides some fundamental knowledge in ultrasound, and then reviews various examples of successful tFUS experiments in animals and humans using different stimulation patterns, as well as available tFUS technologies for generating, focusing, and steering ultrasound beams in neural tissues. In particular, phased array technologies for the ultrasound stimulation application are discussed with an emphasis on the design, fabrication, and integration of ultrasound transducer arrays as well as the design and development of phased array electronics with beamformer and high-voltage driver circuitry. The challenges in tFUS, such as its underlying mechanism, indirect auditory response, and skull aberration effects, are also discussed.

5 August 2022 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
PTPannawit Tipsawat
Pannawit Tipsawat
SISheikh Ilham
Sheikh Ilham
JYJung In Yang
Jung In Yang
ZKZeinab Kashani
Zeinab Kashani
MKMehdi Kiani
Mehdi Kiani
STSusan Trolier-McKinstry
Susan Trolier-McKinstry
Interest in utilizing ultrasound (US) transducers for non-invasive neuromodulation treatment, including for low intensity transcranial focused ultrasound stimulation (tFUS), has grown rapidly. The most widely demonstrated US transducers for tFUS are either bulk piezoelectric transducers or capacitive micromachine transducers (CMUT) which require high voltage excitation to operate. In order to advance the development of the US transducers towards small, portable devices for safe tFUS at large scale, a low voltage array of US transducers with beam focusing and steering capability is of interest. This work presents the design methodology, fabrication, and characterization of 32-element phased array piezoelectric micromachined ultrasound transducers (PMUT) using $1.5~\mu \text{m}$ thick Pb(Zr 0.52 Ti $_{{\mathrm {0.48}}})\text{O}_{3}$ films doped with 2 mol% Nb. The electrode/piezoelectric/electrode stack was deposited on a silicon on insulator (SOI) wafer with a $2~\mu \text{m}$ silicon device layer that serves as the passive elastic layer for bending-mode vibration. The fabricated 32-element PMUT has a central frequency at 1.4 MHz. Ultrasound beam focusing and steering (through beamforming) was demonstrated where the array was driven with 14.6 V square unipolar pulses. The PMUT generated a maximum peak-to-peak focused acoustic pressure output of 0.44 MPa at a focal distance of 20 mm with a 9.2 mm and 1 mm axial and lateral resolution, respectively. The maximum pressure is equivalent to a spatial-peak pulse-average intensity of 1.29 W/cm 2 , which is suitable for tFUS application.