The polycomb group (PcG) proteins are key epigenetic regulators of gene expression in animals and plants. They act in multiprotein complexes, of which the best characterized is the polycomb repressive complex 2 (PRC2), which catalyses the trimethylation of histone H3 at lysine 27 (H3K27me3) at chromatin targets. In Arabidopsis thaliana, PRC2 proteins are involved in the regulation of diverse developmental processes, including cell fate determination, vegetative growth and development, flowering time control and embryogenesis. Here, we systematically analysed the evolutionary conservation and diversification of PRC2 components in lower and higher plants. We searched for and identified PRC2 homologues from the sequenced genomes of several green lineage species, from the unicellular green alga Ostreococcus lucimarinus to more complicated angiosperms. We found that some PRC2 core components, e.g. E(z), ESC/FIE and MSI/p55, are ancient and have multiplied coincidently with multicellular evolution. For one component, some members are newly formed, especially in the Cruciferae. During evolution, higher plants underwent copy number multiplication of various PRC2 components, which occurred independently for each component, without any obvious co-amplification of PRC2 members. Among the amplified members, usually one was well-conserved and the others were more diversified. Gene amplification occurred at different times for different PcG members during green lineage evolution. Certain PRC2 core components or members of them were highly conserved. Our study provides an insight into the evolutionary conservation and diversification of PcG proteins and may guide future functional characterization of these important epigenetic regulators in plants other than Arabidopsis.
The successful integration of renewable energy resources into the power grid hinges on the development of energy storage technologies that are both cost-effective and reliable. These storage technologies, capable of storing energy for durations longer than 10 hours, play a crucial role in mitigating the variability inherent in wind and solar-dominant power systems. To shed light on this matter, a transparent, least-cost macro energy model with user-defined constraints has been utilized for a case study of California. The model addresses all included technologies, solving for both hourly dispatch and installed capacities. Real-world historical demand and hourly weather data have been utilized to do this analysis. A novel approach has been introduced to assess the significance of long-duration energy storage technologies (LDS) in terms of their energy and power capacity. This method explores the contributions of pumped hydropower storage (PHS), compressed air energy storage (CAES), and power-to-gas-to-power (PGP) storage toward minimizing the overall balance of system cost. Historical electricity demand, hourly weather data, and current technology costs are used to investigate high-level implications for California’s power system options. Increasing the storage capacity of each technology from 1 to 10 hours results in 29.6%, 14.4%, and 7.5% cost reduction for PHS, CAES, and PGP cases respectively. However, in studied simulations, maximum availability (maximum) of pumped hydropower storage reduces the balance of system costs by 72.3% followed by CAES (60.6%) and PGP (48.6%) and suggests that pumped hydropower storage in combination with CAES/PGP could play an important role in California’s electricity system, provided that suitable sites can be identified and constructed at reasonable costs.
In the evolving landscape of critical infrastructure security, the increasing sophistication of cyber threats poses challenges, particularly to the power grid’s new technology infrastructure. Despite traditionally being considered passive elements, power transformers, as critical components of the grid, are now equipped with smart technologies and intelligent monitoring systems. These enhancements, while beneficial for asset management, inadvertently increase their vulnerability to cyber threats. Existing literature predominantly focuses on the cybersecurity of smart grids, mainly utilizing model-based detection methods. Yet, there’s a noticeable gap in research on the cybersecurity of critical power components, notably power transformers, within the network. Our paper addresses this oversight by pioneering the examination of cybersecurity challenges presented by smart transformers. We introduce a comprehensive architecture and a well-formed taxonomy of cyber-physical attacks relevant to smart transformers. We present a detailed analysis of smart transformers’ topology, identifying vulnerable components and illustrating the ramifications of cybersecurity breaches. Finally, we discuss potential future cybersecurity challenges facing smart transformers. Our findings underscore the need for integrating advanced cybersecurity measures into the development of online condition monitoring systems, safeguarding power transformers against evolving cyber threats while paving the way for more resilient power grids.
As the ownership of electric vehicles (EVs) continues to rise, EVs are becoming an integral part of urban microgrids. Incorporating the charging and discharging processes of EVs into the microgrid’s optimization scheduling process can serve to load leveling, reducing the reliance of the microgrid on external power networks. This paper proposes a novel two-stage, dual-layer distributed optimization operational approach for microgrids with EVs. The lower layer is a distributed control layer, which ensures, through consensus control methods, that every EV maintains a consistent charging/discharging and state of charge (SOC). The upper layer is the optimization scheduling layer, determining the optimal operational strategy of the microgrid using the multiagent reinforcement learning method and providing control reference signals for the lower layer. Additionally, this paper categorizes the charging process of EVs into two stages based on their SOC: the constrained scheduling stage and the free scheduling stage. By employing distinct control methods during these two stages, we ensure that EVs can participate in the microgrid scheduling while fully respecting the charging interests of the EV owners.