Yijie Li

Yijie Li

Auto-generated profile, based on publicly available information

Yijie Li

State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YLYuying Li
Yuying Li
YLYijie Li
Yijie Li
HLHao Li
Hao Li
ZHZhiliang Hong
Zhiliang Hong
JXJiawei Xu
Jiawei Xu
Non-invasive, closed-loop brain modulation offers an accessible and cost-effective means of evaluating and modulating one’s mental and physical well-being, such as Parkinson’s disease, epilepsy, and sleep disorders. However, wearable EEG systems pose significant challenges for the analog front-end (AFE) circuits in view of μV-level EEG signals of interest, multiple sources of interference, and ill-defined skin contact. This paper presents a direct-digitization AFE tailored for dry-electrode scalp EEG recording, characterized by wide input dynamic range (DR) and high input impedance. The AFE utilizes a second-order 5-bit delta-delta sigma (Δ-ΔΣ) ADC to shape DC electrode offset (DEO) and low-frequency disturbances while retaining high accuracy. A non-inverting pseudo-differential instrumentation amplifier (IA) embedded in the ADC ensures high input impedance (Zin) and common-mode rejection ratio (CMRR). Fabricated in a standard 0.18-μm CMOS process, the AFE delivers 700-mVpp input signal range, 95.3-dB DR, 87-dB SNDR, and 800-MΩ input impedance at 50 Hz while consuming 88.4μW from a 1.2 V supply. The benefits of high DR and high input impedance have been validated by dry-electrode EEG measurement.

25 September 2023 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
YLYijie Li
Yijie Li
WZWeiqi Zhi
Weiqi Zhi
YLYuying Li
Yuying Li
JZJianhong Zhou
Jianhong Zhou
ZHZhiliang Hong
Zhiliang Hong
JXJiawei Xu
Jiawei Xu
This article presents a second-order continuous-time delta-sigma (CT-ΔΣ) based AFE for biopotential sensor interfaces. High linearity is achieved by using a current balanced Gm,1 input stage with gain-boosting and cascode techniques. Low-frequency chopping embedded in gain-boosting OTAs breaks the limitation of chopping frequency in conventional CT-ΔΣ ADCs and mitigates flicker noise without reducing the input impedance. In the second stage, the closedloop Gm,2-OTA-C proportional integrator (PI) relaxes the linearity requirements of the OTA and eliminates the additional active adder. Fabricated in a standard 0.18-μm CMOS technology, this directdigitization AFE achieves 94.9dB peak SNDR, 335mVpp linear input range, and 4.7GΩ input impedance at 50Hz with 64× reduction in the chopping frequency.

8 September 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
LFLairong Fang
Lairong Fang
SZShuwen Zhang
Shuwen Zhang
YLYijie Li
Yijie Li
SWShunmin Wu
Shunmin Wu
XZXiaoyang Zeng
Xiaoyang Zeng
JXJiawei Xu
Jiawei Xu
This article describes a power-efficient, high dynamic range (DR) incremental ADC (IADC) for wearable biopotential signals recording, where DC and low-frequency disturbances such as electrode offset, 50/60 Hz interference and motion artifact must be tolerated. To achieve a wide DR, the IADC performs a three-step conversion by combining zoom-SAR and extended counting (EC) on top of a second-order incremental delta-sigma modulator (ΔΣM). The hybrid architecture notably reduces the oversampling ratio (OSR) with respect to conventional incremental ΔΣMs, while using the EC further improves the Signal-to-Noise-and-Distortion Ratio (SNDR) by 7.4 to 25.6 dB. Fabricated in a 0.18-μm CMOS technology, the IADC achieves 107.6-dB DR, 104.9-dB peak SNR, and 99.3-dB peak SNDR at 2 kS/s while dissipating 130 μW from 1.8-V (analog) / 1.2-V (digital) supply. This translates to a highly competitive FoM DR of 176.5 dB. The high-DR IADC reduces the gain of the preceding instrumentation amplifier (IA) such that significant DC and low-frequency disturbances can be tolerated. The advantages of high DR have been demonstrated by wearable Electrocardiography (ECG) and Electroencephalography (EEG) recordings under motion artifact.

16 September 2025 in IEEE Open Journal of the Solid-State Circuits Society
Verified
Journal Article
Open access
JXJiawei Xu
Jiawei Xu
TQTianxiang Qu
Tianxiang Qu
QPQinjing Pan
Qinjing Pan
YLYijie Li
Yijie Li
LLLiheng Liu
Liheng Liu
ZHZhiliang Hong
Zhiliang Hong
Wearable platforms that concurrently acquire multiple physiological signals enable comprehensive health monitoring but impose stringent requirements on front-end circuit design. The reliable extraction of low-amplitude and low-frequency biosignals is hindered by electrode offset, noise, motion artifacts, and environmental interference. Recent efforts have advanced analog front ends (AFEs) for biopotential (ExG), bioimpedance (BioZ), and photoplethysmography (PPG) sensing, with emphasis on optimizing key metrics such as noise efficiency, input impedance, dynamic range, CMRR, and power consumption. In addition, digitally assisted calibration and direct-digitization schemes have emerged as alternative design directions, offering enhanced robustness and scalability while introducing trade-offs in complexity and energy efficiency. This review surveys these circuit techniques, analyzes their design trade-offs, and outlines future opportunities for next-generation wearable biomedical interfaces.

6 July 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
JLJialin Lu
Jialin Lu
YLYijie Li
Yijie Li
FYFan Yang
Fan Yang
LSLi Shang
Li Shang
XZXuan Zeng
Xuan Zeng
Designing high-performance Δ-Σ modulators is a challenging task, often involving a time-consuming, manual topology search process. We present an automated topology synthesis method for Δ-Σ modulators that significantly improves efficiency in the search for reliable modulator topologies. Our bi-level Bayesian optimization algorithm provides a 41.2%, 24.2%, and 20.2% improvement in FOM compared to random sampling, evolution-based, and general single-level Bayesian optimization methods, respectively. It also achieves a 2.84× speedup compared to single-level BO while achieving the same optimization goal. Our proposed framework allows for better topology-level exploration than existing high-level synthesis software for Δ-Σ modulators, as demonstrated by a case study of a novel high-performance architecture synthesized by our method. The source code and supplementary material are released on GitHub1.

4 April 2025 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YLYijie Li
Yijie Li
YTYuxiang Tang
Yuxiang Tang
JZJianhong Zhou
Jianhong Zhou
TQTianxiang Qu
Tianxiang Qu
ZHZhiliang Hong
Zhiliang Hong
JXJiawei Xu
Jiawei Xu
This article presents a direct-digitization analog front end (DD-AFE) with enhanced input-impedance, common-mode rejection ratio (CMRR), and dynamic range (DR) for wearable biopotential (ExG) signal acquisition, especially for small-diameter dry electrodes. The DD-AFE employs a second-order continuous-time delta-sigma modulator (CT-ΔSM) and multiple circuit techniques to support direct-digitization readouts. These include 1) A high input-impedance input feedforward (FF), embedded in a 4-input 4-bit successive approximation register (SAR) quantizer. This allows two integrators to adopt a compact and energy-efficient Gm-C structure, and improves stability and linearity, resulting in a 6.6dB increase in DR, 42dB increase in SQNR at peak input and a unity-gain signal transfer function (STF) with a gain flatness of 0.04%. 2) A fixed-voltage dead-band assisted tri-level current-steering DAC (IDAC). It not only increases the DR and CMRR of the DD-AFE but also eliminates the harmonic distortion induced by tri-level dynamic element matching (DEM). 3) A high-gain two-stage Gm-boosting inverter-based OTA with embedded low-frequency chopping. The former largely improves linearity and CMRR, while the latter mitigates 1/f noise without compromising the input impedance. Fabricated in a 0.18-μm CMOS process, this DD-AFE achieves 6.4GΩ input impedance and 104.5dB CMRR at 50Hz, as well as 90.4dB peak SNDR, 96dB DR, and up to 425mVPP linear input range.