Michael Walsh

Michael Walsh

Auto-generated profile, based on publicly available information

Michael Walsh

ITER Organization, St. Paul-lez-Durance, France

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
RRR. Reichle
R. Reichle
PAP. Andrew
P. Andrew
PBP. Bates
P. Bates
OBO. Bede
O. Bede
NCN. Casal
N. Casal
MWM. Walsh
M. Walsh


20 January 2020 in Annals of Otology, Rhinology & Laryngology
Verified
Journal Article
Closed access
PDF file
JBJames C. Borders
James C. Borders
MOMeredith B. O’DEa
Meredith B. O’DEa
EMEdel McNally
Edel McNally
ENElizabeth Norberg
Elizabeth Norberg
MKMerertu Kitila
Merertu Kitila
JPJessica M. Pisegna
Jessica M. Pisegna
Sensation is an integral component of laryngeal control for breathing, swallowing, and vocalization. Laryngeal sensation is assessed by elicitation of the laryngeal adductor reflex (LAR), a brainstem-mediated adduction of the true vocal folds. During Flexible Endoscopic Evaluations of Swallowing (FEES), the touch method can be used to elicit the LAR to judge laryngeal sensation. Despite the prevalence of this method in clinical practice and research, prior studies have yet to examine inter- and intra-rater reliability. Four speech-language pathologists rated 125 randomized video clips for the presence, absence, or inability to rate the LAR. Fifty percent of video clips were re-randomized and re-rated 1 week later. Raters then created guidelines and participated in formal consensus training sessions on a separate set of videos. Ratings were repeated post-training. Overall inter-rater reliability was fair (κ = 0.22) prior to training. Pre-training intra-rater reliability ranged from fair (κ = 0.35) to almost perfect (κ = 0.89). Inter-rater reliability significantly improved after training (κ = 0.42, P < .001), though agreement did not reach prespecified acceptable levels (κ ≥ 0.80). Post-training intra-rater reliability ranged from moderate (κ = 0.49) to almost perfect (κ = 0.85). Adequate inter-rater reliability was not achieved when rating isolated attempts to elicit the LAR. Acceptable within-rater reliability was observed in some raters 1 week after initial ratings, suggesting that ratings may remain consistent within raters over a short period of time. Limitations and considerations for future research using the touch method are discussed.

1 January 2020 in Spine
Verified
Journal Article
Closed access
ARAli Rajabian
Ali Rajabian
MWMichael Walsh
Michael Walsh
NQNasir A Quraishi
Nasir A Quraishi
Study Design.: Cadaveric study on fresh unprocessed, nonpreserved, undyed specimens which have not previously been reported. Objective.: We aimed to perform surgically relevant exposures of the anterior cervical spine with particular attention to observing the potential vulnerabilities of the RLN on right and left. Summary of Background Data.: Vulnerability of the RLN in the anterior cervical spine approach on the right versus left is the subject of ongoing debate. Although most cadaveric studies focus on course variations, structural relations of RLN, they have been done in preserved (fixed) cadavers without relevance to the needs of spinal exposure. Methods.: Twelve fresh undyed cadavers had extensive layer by layer dissections by 2 surgeons (one with extensive experience as anatomy dissector). Both sides were explored for vulnerability during cervical spinal procedures. Each dissection was carried out in a phased approach and deliberately explored beyond what can be afforded in live surgery to allow the reader to conceptualize a better view of the structures. Results.: In all specimens, we consistently demonstrated that the right surgical corridor involved manipulation of the nerve and its branches especially below C5 to achieve optimum midline access: in the right corridor, the RLN is on its oblique course to the tracheoesophageal groove. On the left, RLN is already in the tracheoesophageal groove and out of the surgical field involving minimal direct mobilization of the nerve. Conclusion.: RLN surgical anatomy photographed here is novel in using fresh unprocessed cadaveric specimens which has previously not been reported. Right surgical corridor, below C5, involves retraction/manipulation of RLN for achieving optimum spinal midline access, highlighting potential surgical vulnerability of right RLN. Level of Evidence: 3

10 May 2019 in Fusion Science and Technology
Verified
Journal Article
Closed access
LBL. Begrambekov
L. Begrambekov
AGA. Gordeev
A. Gordeev
YMY. Ma
Y. Ma
GVG. Vayakis
G. Vayakis
PSP. Shigin
P. Shigin
MWM. Walsh
M. Walsh
High-quality tungsten coating deposition on sintered aluminum nitride ceramic substrates (both of thin flat chips and structural boxes) was realized using an adapted plasma-aided coating deposition rig. The tungsten coating produced using this technique and the accompanying apparatus setup are of high-purity, strong adhesion, and controlled three-dimensional uniformity (<20% thickness variations). The coating also exhibits well-structured and smooth (Ra < 1.0 µm) microscopic surface landscape with densely clustered tungsten granulations. The coated samples were tested under load conditions expected during ITER operation, including thermal cycling and superheated (up to 500°C) steam. Exposure to thermal cycles and hot steam made no apparent changes to the coating’s microscopic structure with no sign of cracks, blistering, or exfoliation seen under electron microscopy. These successes validated the microwave shield design for the ITER high-frequency magnetic sensor, which is based on this concept, and laid a solid foundation for the production of this component in the forthcoming procurement phase. Besides, a failure test was conducted for the tungsten coating in the temperature range of 500°C to 1500°C. Surface smoothing, pores, delamination, and mass loss in substrate were observed when temperature exceeded 1000°C, possibly due to the evaporation of aluminum atoms. These findings unveiled the changes of tungsten coating properties under extreme conditions that are of both academic and practical values.

1 February 2022 in Journal of Instrumentation
Verified
Journal Article
Closed access
ADA. Danisi
A. Danisi
GVG. Vayakis
G. Vayakis
MWM. Walsh
M. Walsh
Several optical diagnostics in the ITER fusion reactor make use of big mirrors which are placed within the ITER vacuum vessel (VV), and therefore cannot have high accessibility. Plasma deposits developing on these mirrors may hinder the reflectivity of the mirror themselves, requiring a remote cleaning operation. The radio-frequency (RF) discharge mirror cleaning service operates a plasma discharge in the vicinity of the mirror, eroding the deposit layer and therefore cleaning the mirror remotely. In order to achieve this, RF power needs to be sent from outside the VV to the mirror, using a transmission line. Very stringent design requirements are applicable to the design of this RF line, such as vacuum compatibility, high power handling, low losses, overall matching, no cable over-heating, etc. This paper analytically addresses the design optimization of the RF mirror cleaning transmission line, taking into account ITER requirements, in order to give robust guidelines for the possible ad-hoc cable design adaptation that is to be undertaken case-by-case. The design guidelines are based on underlying transmission line theory, from which a set of design equations are drawn. The optimal design is achieved using design optimization considerations in the available design space. These guidelines are considered to be a useful design tool for optical diagnostics requiring mirror cleaning operation, and are aimed at harmonising the transmission line design procedures across the different cases.