5 August 2020 in ESC Heart Failure
Aims Acute right heart failure (RHF) is a severe complication of right ventricular infarction. The management of acute RHF poses a number of challenges, such as providing haemodynamic support. Temporary circulatory support (TCS) may be required upon failing medical therapy. The ProtekDuo® dual lumen cannula provides a minimally invasive option for (TCS) through a groin‐free internal jugular vein approach. We present the largest patient series to date using the ProtekDuo® cannula as temporary right ventricular assist device (t‐RVAD) in RHF after acute myocardial infarction (MI). Methods and results From July 2016 to November 2019, 10 patients underwent t‐RVAD implantation for RHF following acute MI. Transthoracic and transoesophageal echocardiography were performed in all patients to assess cardiac function, with a particular focus on RV function. Cumulative 30‐day survival was 60%. Mean TAPSE was 6.4 ± 3.1 mm, mean fractional area change was 12.1 ± 4.2%, and mean right ventricular end diastolic area was 19.8 ± 2.7 cm2. Mean implantation time was 32.8 ± 8.3 min. Mean interval after first cardiac intervention was 4.6 ± 5.8 days. Mean t‐RVAD time was 10.0 ± 7.4 days with a significant reduction in central venous pressure 19.3 ± 2.7 vs. 8.2 ± 2.6 mmHg, P < 0.001 and a significant increase in central venous saturation 52.8 ± 15.6 vs. 80.0 ± 6.0%, P < 0.001. Mean intensive care unit stay was 18.6 ± 12.2 days. Four patients were weaned from TCS. Two patients were bridged to a long‐term paracorporeal RVAD. There were no t‐RVAD associated complications. Causes of death (n = 4) were multiorgan failure, electromechanical dissociation, and haemorrhagic stroke. Mean follow‐up time was 96.0 ± 107.6 days. No independent predictors of mortality were identified in univariate analysis. Conclusions We show that groin‐free, percutaneous implantation of the ProtekDuo® cannula is a feasible and safe tool for TCS in acute RHF post‐MI. This approach provides the advantages of percutaneous implantation including complete mobilization and non‐surgical bedside explantation, as well as the option for adding an oxygenator to the t‐RVAD circuit.
1 August 2019 in Journal of Cardiothoracic Surgery
The frozen elephant trunk (FET) technique was developed to facilitate the two-stage surgery of extensive pathologies of the thoracic aorta and is now routinely applied in acute and chronic aortic syndromes. From 11/2006 to 07/2017, 68 patients underwent aortic arch repair using the FET technique. Patients received either the Jotec E-vita Open graft (n = 57) or the Vascutek Thoraflex hybrid prosthesis (n = 11). Both, group 1 (acute aortic dissection type A and B; symptomatic penetrating aortic ulcer) and group 2 (aortic aneurysm; chronic aortic dissection) included 34 patients each. Early mortality was 13.2% (14.7% in group 1 vs. 11.7% in group 2, p = 0.720). Neurological complications occurred in 12 patients (17.6%) (stroke: 8.8 vs. 11.7%; p = 0.797 and spinal cord injury: 8.8 vs. 5.9%; p = 0.642 in groups 1 vs. 2 respectively). Cardiopulmonary bypass time and cross clamp time were significantly longer in group 1 (252.2 ± 73.5 and 148.3 ± 34 min vs. 189.2 ± 47.8 and 116.3 ± 34.5 min; p < 0.001). The overall 1-, 3- and 7-year-survival was 80.9, 80.9 and 74.2% with no significant differences between groups 1 and 2. Expansion of true lumen after FET implantation was significant at all levels in both groups for patients with aortic dissection. One-, 3-, and 7-year-freedom from secondary (re-)intervention for patients for aortic dissection was 96.9, 90.2 and 82.7% with no significant differences between groups 1 and 2; p = 0.575. The FET technique can be applied in acute aortic syndromes with similar risks regarding adverse events or mortality when compared to chronic degenerative aortic disease. Postoperative increase in true lumen diameter mirrors decrease of false lumen diameter, goes along with favorable midterm outcome and prolongs freedom from secondary interventions in acute aortic dissection.
1 December 2017 in The American Journal of Emergency Medicine
1 February 2021 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: Our goal was to evaluate the use of the frozen elephant trunk (FET) technique for the treatment of penetrating aortic ulcers involving the aortic arch. METHODS: Between January 2008 and January 2020, a total of 34 patients had the FET technique at 3 aortic centres. The indication for the FET technique was unsuitability for thoracic endovascular aortic repair due to the lack of a sufficient proximal landing zone even after supra-aortic rerouting (subclavian transposition, double transposition), ectasia of the ascending aorta/aortic arch (>40 mm) and/or a shaggy proximal thoracic aorta. RESULTS: Additional cardiac procedures were performed in 14 patients (41%), and the beating heart technique was used in 7 patients (21%). Perioperative mortality was 18% (n = 6); 3 of these patients had a major stroke (9%). No case of spinal cord ischaemia was observed, and 2 patients (6%) developed a non-disabling stroke. After a median follow-up of 7 (first quartile: 1; third quartile 29) months, 2 patients (6%) died (1 of malignant disease and 1 of an unclear cause); 10 additional aortic interventions in all aortic segments (29%; endovascular: n = 8 [24%] and conventional surgical: n = 2 [6%]) were performed in 8 patients. CONCLUSIONS: The FET technique is a good treatment option for patients with penetrating aortic ulcers involving the aortic arch unsuitable for thoracic endovascular aortic repair. However, the high obliterative atherosclerotic load in these patients is accompanied by an un-neglectable risk of perioperative neurological injury. Concomitant cardiac surgical procedures are frequently needed. Patients commonly require secondary aortic procedures in all aortic segments, emphasizing the need for thorough primary conceptual planning and stringent follow-up.