Majid Komeili

Majid Komeili

Auto-generated profile, based on publicly available information

Majid Komeili

Carleton University, Ottawa, Ontario, Canada

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2018 in IEEE Transactions on Information Forensics and Security
Verified
Journal Article
Closed access
MKMajid Komeili
Majid Komeili
NANarges Armanfard
Narges Armanfard
DHDimitrios Hatzinakos
Dimitrios Hatzinakos
Fingerprints have been extensively used for biometric recognition around the world. However, fingerprints are not secrets, and an adversary can synthesis a fake finger to spoof the biometric system. The mainstream of the current fingerprint spoof detection methods are basically binary classifier trained on some real and fake samples. While they perform well on detecting fake samples created by using the same methods used for training, their performance degrades when encountering fake samples created by a novel spoofing method. In this paper, we approach the problem from a different perspective by incorporating electrocardiogram (ECG). Compared with the conventional biometrics, stealing someone's ECG is far more difficult if not impossible. Considering that ECG is a vital signal and motivated by its inherent liveness, we propose to combine it with a fingerprint liveness detection algorithm. The combination is natural as both ECG and fingerprints can be captured from fingertips. In the proposed framework, the ECG and fingerprint are combined not only for authentication purpose but also for liveness detection. We also examine automatic template updating using ECG and fingerprint. In addition, we propose a stopping criterion that reduces the average waiting time for signal acquisition. We have performed extensive experiments on the LivDet2015 database which is presently the latest available liveness detection database and compare the proposed method with six liveness detection methods as well as 12 participants of LivDet2015 competition. The proposed system has achieved a liveness detection equal error rate (EER) of 4.2% incorporating only 5 s of ECG. By extending the recording time to 30 s, liveness detection EER reduces to 2.6% which is about 4 times better than the best of six comparison methods. This is also about 2 times better than the best results achieved by the participants of the LivDet2015 competition.

16 May 2017 in IEEE Transactions on Cybernetics
Verified
Journal Article
Open access
MKMajid Komeili
Majid Komeili
WLWael Louis
Wael Louis
NANarges Armanfard
Narges Armanfard
DHDimitrios Hatzinakos
Dimitrios Hatzinakos
Electrocardiogram (ECG) and transient evoked otoacoustic emission (TEOAE) are among the physiological signals that have attracted significant interest in biometric community due to their inherent robustness to replay and falsification attacks. However, they are time-dependent signals and this makes them hard to deal with in across-session human recognition scenario where only one session is available for enrollment. This paper presents a novel feature selection method to address this issue. It is based on an auxiliary dataset with multiple sessions where it selects a subset of features that are more persistent across different sessions. It uses local information in terms of sample margins while enforcing an across-session measure. This makes it a perfect fit for aforementioned biometric recognition problem. Comprehensive experiments on ECG and TEOAE variability due to time lapse and body posture are done. Performance of the proposed method is compared against seven state-of-the-art feature selection algorithms as well as another six approaches in the area of ECG and TEOAE biometric recognition. Experimental results demonstrate that the proposed method performs noticeably better than other algorithms.

15 April 2020 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
MKMajid Komeili
Majid Komeili
NANarges Armanfard
Narges Armanfard
DHDimitrios Hatzinakos
Dimitrios Hatzinakos
In many real-world scenarios, data from multiple modalities (sources) are collected during a development phase. Such data are referred to as multiview data. While additional information from multiple views often improves the performance, collecting data from such additional views during the testing phase may not be desired due to the high costs associated with measuring such views or, unavailability of such additional views. Therefore, in many applications, despite having a multiview training data set, it is desired to do performance testing using data from only one view. In this paper, we present a multiview feature selection method that leverages the knowledge of all views and use it to guide the feature selection process in an individual view. We realize this via a multiview feature weighting scheme such that the local margins of samples in each view are maximized and similarities of samples to some reference points in different views are preserved. Also, the proposed formulation can be used for cross-view matching when the view-specific feature weights are pre-computed on an auxiliary data set. Promising results have been achieved on nine real-world data sets as well as three biometric recognition applications. On average, the proposed feature selection method has improved the classification error rate by 31 percent of the error rate of the state-of-the-art.

24 October 2018 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
NANarges Armanfard
Narges Armanfard
MKMajid Komeili
Majid Komeili
JRJames P. Reilly
James P. Reilly
JCJohn Connolly
John Connolly
Mismatch Negativity (MMN) is a component of the event-related potential (ERP) that is elicited through an odd-ball paradigm. The existence of the MMN in a coma patient has a good correlation with coma emergence; however, this component can be difficult to detect. Previously, MMN detection was based on visual inspection of the averaged ERPs by a skilled clinician, a process which is expensive and not always feasible in practice. In this paper we propose a practical machine learning (ML) based approach for detection of the MMN component, thus improving the accuracy of prediction of emergence from coma. Further, the method can operate on an automatic and continuous basis, thus alleviating the need for clinician involvement. The proposed method is capable of MMN detection over intervals as short as two minutes. This finer time resolution enables identification of waxing and waning cycles of a conscious state. An auditory odd-ball paradigm was applied to 22 healthy subjects and 2 coma patients. A coma patient is tested by measuring the similarity of the patient's ERP responses with the aggregate healthy responses. Because the training process for measuring similarity requires only healthy subjects, the complexity and practicality of training procedure of the proposed method are greatly improved relative to training on coma patients directly. Since there are only two coma patients involved with this study, the results are reported on a very preliminary basis. Preliminary results indicate we can detect the MMN component with an accuracy of 92.7% on healthy subjects. The method successfully predicted emergence in both coma patients when conventional methods failed. The proposed method for collecting training data using exclusively healthy subjects is a novel approach that may prove useful in future, unrelated studies where machine learning methods are used.

28 November 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
SHSahar Javaher Haghighi
Sahar Javaher Haghighi
MKMajid Komeili
Majid Komeili
DHDimitrios Hatzinakos
Dimitrios Hatzinakos
HBHossam El Beheiry
Hossam El Beheiry
This paper proposes an anaesthesia monitoring system that accurately measures the depth of anaesthesia through 40-Hz auditory steady-state response. With accurate and fast depth of anaesthesia measuring, the monitor can reduce the incidence of awareness during surgical operation. The proposed denoising method for extracting 40-Hz auditory steady-state cycles, adaptive multilevel wavelet denoising, enabled the system to extract auditory steady-state response cycles from fewer epochs and over short periods of time which is of crucial importance in monitoring anaesthesia. The noise estimation scheme, adaptive threshold levels, rearranging, and multilevel denoising of frames increase the accuracy and signal to noise ratio of the extracted cycles. The modified fuzzy c-means clustering scheme, proposed to improve clustering performance in noisy data bases where no prior information about the level of noise and signal energy is available, is used for clustering the auditory steady-state cycles. Weighting the features with a novel algorithm and based on their differentiating role in clustering, the modified fuzzy c-means improves fuzziness in cluster partitions and the geometrical structure of the data. An index called depth of anaesthesia index is defined and determined at each cycle based on the clustering information of the cycle and the previous ones. The algorithm is applied to auditory steady-state response signals recorded from 20 human subjects during surgical operations with Propofol-induced general anaesthesia. The accuracy of the depth of anaesthesia index is validated through the subjects' medical markers, clinical parameters, and the recorded bispectral index during the induction phase. Depth of anaesthesia index is verified to be accurate and able to detect fast transitions between different levels of anaesthesia. The computed depth of anaesthesia indices detected the induction of anaesthesia on average 55 s faster than bispectral index and 17 s earlier than loss of eyelash reflex.

28 October 2024 in Neurocomputing
Verified
Journal Article
Closed access
MZMohammad Reza Zarei
Mohammad Reza Zarei
MKMajid Komeili
Majid Komeili