1 November 2015 in Engineering Structures
1 February 2017 in Journal of Bridge Engineering
Perfobond rib shear connector (PBL) is capable of transferring large internal force between steel and concrete components. It has been widely used in composite bridges as a key load-transferring component. In this paper, the load-transfer mechanism of the PBL shear connector group is investigated theoretically and experimentally. An analytical model was developed based on load-slip characteristics of a single shear connector and load-deformation compatibility of a perforated steel plate and concrete component. The model was validated through full-scale connection loading experiments. Test results indicate that the applied load is unevenly distributed to multiple layers of PBL shear connectors in a connector group in the elastic stage, and the load becomes more evenly distributed as plastic deformation of the connectors takes place. The presented analytical model provides an efficient way for analyzing and designing a PBL shear connector group. The analytical results indicate that increasing the number of connectors in heavily loaded layers helps effectively reduce the load shared by each connector in these layers under design loads.
1 January 2017 in Journal of Bridge Engineering
For multispan suspension bridges, frictional resistance between the main cables and the saddles is essential for counterpoising unbalanced cable tension between different spans. The use of friction plates in saddles is one of the most common methods for increasing frictional resistance, and the corresponding evaluation method is vital for the design of suspension bridges. In this study, an analytical model for the calculation of frictional resistance between cables and saddles is presented. Large-scale model tests were performed to simulate the realistic friction conditions of a typical multispan suspension bridge in China, namely the Yingwuzhou Yangtze River Bridge, to validate the model. The main components of frictional resistance were analyzed, and the effects of vertical friction plates in enhancing frictional resistance were investigated by model tests and theoretical analyses. The results indicate that the presented analytical model provides an effective and feasible tool for evaluating the total frictional resistance and the contribution of friction plates in practice. The main components of total frictional resistance, including the frictions at the base and side contact interfaces between the cable and the saddle trough, are quantified, proving the former to be dominant. The parameter analyses reveal that the frictional resistance can be increased by 57% by incorporating six vertical friction plates for the actual saddle.
1 November 2017 in Journal of Bridge Engineering
The flow field around a horizontally oscillating bridge pier during earthquakes is characterized by a high Reynolds number and a small Keulegan-Carpenter number. This study aimed at the fluid forces exerted on a circular bridge pier in quiescent water during earthquakes. By scaling the hydrodynamic equations, it is analytically shown that the inertial force dominates the drag force. This characteristic is further demonstrated by performing numerical simulations. A given earthquake is first decomposed into a series of equivalent harmonic components. Then, the hydrodynamic forces are computed in the numerical code. The numerical results confirm that the inertial force dominates the drag force, and the inertial coefficient is essentially equal to 1 for all conditions examined for the monochromatic and two-frequency oscillations as well as the actual earthquakes. This confirmation is crucial, because the dominance of inertial force means that the resultant force can be predicted with the linear superposition of decomposed frequency components, owing to the inertial force being linear in the fluid-flow acceleration.
1 October 2017 in Journal of Bridge Engineering
The perfobond rib (PBL) shear connector group composed of multiple layers of PBL shear connectors has been proven to be one of the most effective load-transferring components and is widely used in cable-stayed bridges. In this study, an analytical method was developed to analyze the internal force transfer of a PBL shear connector group, based on the nonlinear equivalent stiffness of key components, which include the shear connectors, perforated steel plate, and concrete base. Explicit analytical expressions of the internal force distribution among different layers of shear connectors were derived and validated against experimental results. Uneven force distributions resulting from the different equivalent stiffnesses of different layers of shear connectors were demonstrated. Key factors influencing the load distribution include the stiffness of the perforated steel plate, concrete base, and shear connectors. The unevenness of the load distribution was found to gradually decrease with the development of plastic deformation of the shear connectors. The proposed method offers an efficient and practical approach to investigating the mechanical behavior of a PBL shear connector group and quantifying its property of uneven internal force distribution.
1 April 2013 in Advances in Structural Engineering
This paper evaluates the ultimate shear resistance(USR) of the perfobond rib shear connector(PRSC) based on a modified push-out test and establishes a new equation for the USR. 33 modified push-out specimens were constructed and tested. The specimens had different perfobond bar diameters, perfobond rib hole diameters, concrete strengthes and transversal rebar quantities. From the test results, influencing factors of the USR such as the ultimate tensile capacity of perfobond bars, the shear stiffness of concrete dowels and the number of transversal rebar were evaluated experimentally. An new equation was developed based on regression analysis for the USR. This equation predicts the USR to within 14% of the experimental results in this test and the push-out tests for PRSC in pylon joint segments.