Hector Willem Livius de Beaufort

Hector Willem Livius de Beaufort

Auto-generated profile, based on publicly available information

Hector Willem Livius de Beaufort

Department of Cardiothoracic Surgery, St. Antonius Hospital , 3435 CM Nieuwegein

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HBHector W. L. de Beaufort
Hector W. L. de Beaufort
MCMargherita Coda
Margherita Coda
MCMichele Conti
Michele Conti
TBTheodorus M. J. van Bakel
Theodorus M. J. van Bakel
FNFoeke J. H. Nauta
Foeke J. H. Nauta
STSanti Trimarchi
Santi Trimarchi
Thoracic endovascular aortic repair (TEVAR) has been shown to lead to increased aortic stiffness. The aim of this study was to investigate the effect of stent graft type and stent graft length on aortic stiffness in a controlled, experimental setting. Twenty porcine thoracic aortas were connected to a pulsatile mock loop system. Intraluminal pressure was recorded at two sites in order to measure pulse wave velocity (PWV) for each aorta: before stent graft deployment (t1); after deployment of a 100-mm long stent graft (t2); and after distal extension through deployment of a second 100-mm long stent graft (t3). Four different types of stent grafts (Conformable Gore® TAG® Device, Bolton Relay® Device, Cook Zenith Alpha™, and Medtronic Valiant®) were evaluated. For the total cohort of 20 aortas, PWV increased by a mean 0.6 m/s or 8.9% of baseline PWV after deployment of a 100-mm proximal stent graft (P<0.001), and by a mean 1.4 m/s or 23.0% of baseline PWV after distal extension of the stent graft (P<0.001). Univariable regression analysis showed a significant correlation between aortic PWV and extent of stent graft coverage, (P<0.001), but no significant effect of baseline aortic length, baseline aortic PWV, or stent graft type on the percentual increase in PWV at t2 or at t3. In this experimental set-up, aortic stiffness increased significantly after stent graft deployment with each of the four types of stent graft, with the increase in aortic stiffness depending on the extent of stent graft coverage.

12 December 2020 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
MFMariafrancesca Fiorentino
Mariafrancesca Fiorentino
HBHector W L de Beaufort
Hector W L de Beaufort
USUday Sonker
Uday Sonker
RHRobin H Heijmen
Robin H Heijmen
OBJECTIVES: The frozen elephant trunk technique is an increasingly common treatment for extensive disease of the thoracic aorta. The objective of the study was to evaluate the outcomes of frozen elephant trunk specifically in chronic (residual) aortic dissections, focusing on downstream aortic remodelling. METHODS: Between 2013 and 2019, a total of 28 patients were treated using the Vascutek Thoraflex hybrid graft at our institution for chronic dissections/post-dissection aneurysms. Immediate and follow-up outcomes were studied, as well as the changes in total aortic diameter, true lumen and false lumen diameter and the status of the false lumen at 3 different levels of the thoraco-abdominal aorta. RESULTS: No in-hospital or 30-day mortality was observed, temporary paraparesis rate was 7% and disabling stroke incidence was 14.3%. Freedom from all-cause mortality at 2 years was 91.6 ± 5.7%, while freedom from reintervention on the downstream aorta at 2 years was 59.1 ± 10.8%. Positive aortic remodelling was achieved in 50.0%, with an enlargement in the true lumen and a reduction of the false lumen not only at the level of the proximal descending aorta with 73.1% of complete thrombosis but also at the level of the distal descending thoracic aorta, with 41.7% of complete thrombosis. CONCLUSIONS: The frozen elephant trunk is a good solution in chronic (residual) downstream aortic dissections inducing positive aortic remodelling and preventing from II stage operations or allowing an endovascular approach.

7 November 2022 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
HBHector Willem Livius de Beaufort
Hector Willem Livius de Beaufort
JVJan Albert Vos
Jan Albert Vos
RHRobin H. Heijmen
Robin H. Heijmen
Objective: Effectiveness of thoracic endovascular aortic repair in type B aortic dissection is impaired by persistent retrograde false lumen flow via distal re-entry tears. Controlled, stentgraft-assisted balloon dilatation of the true lumen at its lower end, or Knickerbocker technique, may block retrograde false lumen flow and consequently improve effectiveness by inducing immediate thrombosis along the entire descending thoracic aorta. Materials and Methods: A single-center retrospective analysis was performed for all consecutive patients with aortic dissection treated with the Knickerbocker technique to block retrograde false lumen flow. Results: Eleven patients were included for analysis. Intraoperative control angiography showed successful occlusion of the false lumen at the level of balloon dilatation in 9 out of 11 patients (82%). There was one perioperative mortality (9%), due to stroke. There were 2 early reinterventions, due to retroperitoneal bleeding and due to chyle leakage in the neck after left subclavian artery bypass. Median clinical follow-up duration was 6 (interquartile range [IQR] 2–11] months. There were 2 deaths during follow-up, one at 2 months after TEVAR from unknown cause of death, and one after 11 months due to rupture of an ascending aortic pseudoaneurysm. The Knickerbocker technique led to positive aortic remodeling. At 3 months follow-up, 100% of patients showed complete false lumen thrombosis in the thoracic aorta proximal to the level of balloon dilatation, with decreasing false lumen diameters (100%) and stable (44%) or decreasing (56%) total aortic diameters. In most patients, the false lumen distal to the stentgraft (i.e. at visceral level) remained patent (11% false lumen thrombosis rate), leading to ≥2 mm dilatation at this level (78% of patients) and in the infrarenal abdominal aorta (56% of patients) at 3 months postoperatively. No distal stent-graft-induced new entry tears were noticed during follow-up. Conclusion: The Knickerbocker technique is feasible and effective, leading to positive aortic remodeling of the aorta covered by stentgraft in all of a small cohort of patients. Clinical Impact: Persistent, retrograde false lumen perfusion from distal re-entries following thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection, may lead to progressive, aneurysmal dilatation. Controlled, stent graft-assisted balloon dilatation of the true lumen in the distal descending aorta (i.e. Knickerbocker technique) during TEVAR effectively excludes the false lumen from persistent flow resulting in positive aortic remodeling in our small cohort of patients, and hence potentially eliminates the risk of late post-dissection aneurysm formation in the descending thoracic aorta.

1 May 2024 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
EDEdgar J Daeter
Edgar J Daeter
HBHector W L de Beaufort
Hector W L de Beaufort
MRMaaike M Roefs
Maaike M Roefs
WBWim Jan P van Boven
Wim Jan P van Boven
DVDennis van Veghel
Dennis van Veghel
YDY L Douglas
Y L Douglas
The aim of this study was to describe trends and outcomes for patients undergoing surgical aortic valve replacement (SAVR) in the Netherlands. The Netherlands Heart Registration database was used to report the number and outcomes of isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients. A total of 17 142 procedures were included, of which 77.9% were performed using a biological prosthesis and 21.0% with a mechanical prosthesis. Median logistic EuroSCORE I decreased from 4.6 [interquartile range (IQR) 2.4–7.7] to 4.0 (IQR 2.6–6.0). The 120-day mortality decreased from 3.3% in 2007 to 0.7% in 2018. The median duration of follow-up was 76 months (IQR 53–111). Ten-year survival, when adjusted for age, EuroSCORE I and body surface area, was 72.4%, and adjusted 10-year freedom from reinvervention was 98.1%. Additional analysis for patients under the age of 60 showed no difference between patients treated with a biological or mechanical prosthesis in adjusted 10-year survival, 89.7% vs 91.9±%, respectively (P = 0.25), but a significant difference in adjusted 10-year freedom from reintervention, 90.0±% vs 95.9%, respectively (P < 0.01). Between 2007 and 2018, age and risk profile of patients undergoing SAVR decreased, especially for patients treated with a biological prosthesis. The 120-day mortality decreased over time. Patients undergoing SAVR nowadays have a risk of 120-day mortality of 95%.

19 October 2020 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
HBHector W. L. de Beaufort
Hector W. L. de Beaufort
LLLuigi Lovato
Luigi Lovato
AVAndres Reyes Valdivia
Andres Reyes Valdivia
TKTheodoros Kratimenos
Theodoros Kratimenos
GRGiovanni Rossi
Giovanni Rossi
RHRobin H. Heijmen
Robin H. Heijmen
Purpose: To describe steps related to intraoperative C-arm orientations that can be taken during preoperative planning of thoracic stent-graft repair to facilitate the deployment of EndoAnchors in the distal aortic arch. Technique: Previous experience from transcatheter aortic valve implantation (TAVI) may be helpful in addressing issues with C-arm orientation. In TAVI, preoperative computed tomography (CT) images are routinely obtained to generate a patient-specific curve that represents a virtually complete rotation of the C-arm perpendicular to the annulus. The curve clearly demonstrates that each adjustment in cranial or caudal view needs parallax correction in the left or right anterior oblique direction to remain perpendicular, and vice versa. This experience can be translated to the preoperative planning of EndoAnchor use in the aortic arch. By placing markers along the circumference of the proximal landing zone of the preoperative CT scan, the required C-arm orientations can be determined for each marker. Conclusion: Determining the optimal C-arm orientation during preoperative planning will facilitate successful EndoAnchor deployment and may contribute to improved durability of endovascular repair in hostile necks in the aortic arch.

15 May 2023
Verified
Journal Article
Closed access
HBHector W L de Beaufort
Hector W L de Beaufort
VGVincent P Groot
Vincent P Groot
TBThomas L Bollen
Thomas L Bollen
KBKoen F Berben
Koen F Berben
MWM J Wiezer
M J Wiezer