Shahriar Sarmast Ghahfarokhi

Shahriar Sarmast Ghahfarokhi

Auto-generated profile, based on publicly available information

Shahriar Sarmast Ghahfarokhi

Department of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
KAKhizra Abbas
Khizra Abbas
LGLakshmi Priya Gandla
Lakshmi Priya Gandla
SGShahriar Sarmast Ghahfarokhi
Shahriar Sarmast Ghahfarokhi
KKKonstantin Kostov
Konstantin Kostov
HNHans-Peter Nee
Hans-Peter Nee
This article presents a soft-switched buck converter employing autonomous gate drivers (AGDs) for high-performance power electronic systems. Operating at a 400~V dc-link, representative of electric vehicle (EV) and industrial applications, the converter achieves zero-voltage switching (ZVS) during both turn-on and turn-off through fully analog AGD circuitry and optimized snubber capacitance. The converter operates in triangular current mode (TCM), leveraging the inherent inductor current ripple to enable ZVS without digital control. Experimental results demonstrate reliable soft switching, reduced switching losses, and effective suppression of voltage overshoot under realistic operating conditions. Although validated using a buck converter, the proposed AGD concept is directly applicable to more complex topologies, including three-phase inverters with sinusoidal reference currents, relevant to EV traction drives, renewable energy systems, and industrial converters. This work highlights a scalable, hardware-efficient approach for improving efficiency and performance in next-generation high-voltage power converters.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
KAKhizra Abbas
Khizra Abbas
BCBhaskar Chatterjee
Bhaskar Chatterjee
ARAntonio Cameo Del Rey
Antonio Cameo Del Rey
SGShahriar Sarmast Ghahfarokhi
Shahriar Sarmast Ghahfarokhi
EAEnes Ayaz
Enes Ayaz
HNHans-Peter Nee
Hans-Peter Nee

26 May 2026 in IEEE Access
Verified
Journal Article
Open access
EAEnes Ayaz
Enes Ayaz
SGShahriar Sarmast Ghahfarokhi
Shahriar Sarmast Ghahfarokhi
SNStaffan Norrga
Staffan Norrga
HNHans-Peter Nee
Hans-Peter Nee
The electrification of heavy-duty vehicles (HDVs) is essential for achieving zero-emission freight transport. Conventional 400–800 V powertrains face limitations in supporting megawatt-level fast charging and high continuous power due to excessive current, cable losses, and thermal stress. Recent advances in high voltage (i.e., 1.7 kV, 2 kV, 3.3 kV) silicon-carbide (SiC) power modules and charging standards such as the Megawatt Charging System (MCS, up to 1250 V) have enabled a new generation of 1.2 kV dc-link architectures for HDVs. This paper presents a comprehensive system-level evaluation of increasing the dc-link voltage from 800 V to 1.2 kV, covering the battery, inverter, and motor subsystems. The battery/charging and motor-level results are presented as analytical first-order assessments, whereas the inverter-level loss-modelling methodology is experimentally validated on a 250 kW, 1.2 kV dc-link SiC prototype. A virtual-prototyping framework is used to quantify inverter losses, thermal behavior, and volume trade-offs, and the switching frequency is optimized by jointly considering inverter and motor harmonic losses. Experimental results showthat the analytical models predict measured inverter losses within approximately 10% over the tested operating range. Under the representative charging assumptions adopted in this study, 1.2 kV dc-link voltage enables either an∼56% reduction in cable conduction losses or an∼33% reduction in cable mass, while the prototype achieves an efficiency of ∼99.12%, a specific power density of 49.4 kW/L, and a bounding-box-based volumetric power density of 20.83 kW/L. The results provide system-level assessment and experimentally supported inverter-level design guidance for 1.2 kV HDV powertrains.