Lei Ma

Lei Ma

Auto-generated profile, based on publicly available information

Lei Ma

Department of Power Engineering, School of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2021 in IEEE Access
Verified
Journal Article
Open access
JMJianqiao Ma
Jianqiao Ma
LMLei Ma
Lei Ma
XWXiangfei Wang
Xiangfei Wang
ZQZhibin Qi
Zhibin Qi
ZSZhenlong Sun
Zhenlong Sun
In order to exercise control on the maximal intensity of electric field for the pantograph post insulators and fittings surface on high-speed trains, the finite element software COMSOL was applied to analyze the electric field distribution of post insulators in the presence and absence of the grading ring. According to the simulation results, the depth and degree of grading ring are the significant influencing factors in the distribution of electric field along the insulator surface and the surrounding air area. Based on these simulation results, the solid model was processed and the lightning impulse flashover voltage test was carried out. As indicated by the test results, the permissible lightning impulse voltage of 50% negative polarity exhibited a linear relationship with the depth value, while 50% of the permissible lightning impulse voltage generated with the addition of grading ring cover that was 70mm in depth satisfied the requirement of 170kV as specified in OV4 standard. Based on the results of simulation analysis and test, the parameters of the grading ring that can be applied in engineering works were identified in this paper, thus providing a reference for the adoption of the scheme to reduce the abnormal flashover frequency induced by the local high intensity electric field.

28 September 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
JMJianqiao Ma
Jianqiao Ma
LMLei Ma
Lei Ma
GYGuangze Yang
Guangze Yang
YWYouqiang Wu
Youqiang Wu
In order to improve the insulation capacity of cable connector (Cc) in the high voltage equipment box (Hveb), this paper proposes an optimization scheme that does not change the size of the Hveb and the structure of Cc fittings. In this paper, the change in the impulse voltage withstand value of Cc after installing insulating sheath was verified by the lightning impulse flashover test. Based on the finite element software and the structure of Cc fittings, a special shaped shielding ring (Sr) was designed to adjust the partial area where the electric field intensity are concentrated. Besides, the optimal parameters of the Sr under different working conditions were determined by the orthogonal design. Finally, Utilizing ultraviolet (UV) imaging technology and image processing method, the discharge intensity of Cc fittings were characterized. The results demonstrate that with the combination of insulation measures, the impulse voltage withstand value of Cc can be increased from 155kV to 235kV; The maximum electric field strength on the surface of bolts and metal electrode can be reduced by 57.8% and 72%; UV discharge facular area had an exponential relationship with the applied voltage, the initial discharge voltage of Cc can increase by 243% after installing the Sr.