2 October 2019 in Science Translational Medicine
Recreated missing leg sensations, connected to the prosthesis sensors, restored leg functional abilities and promoted its cognitive integration.
23 April 2021 in Science Advances
Restoring neural sensory feedback to amputees improves the exploitation of leg prosthesis during motor tasks.
17 December 2019 in Scientific Reports
Although peripheral nerve stimulation using intraneural electrodes has been shown to be an effective and reliable solution to restore sensory feedback after hand loss, there have been no reports on the characterization of multi-channel stimulation. A deeper understanding of how the simultaneous stimulation of multiple electrode channels affects the evoked sensations should help in improving the definition of encoding strategies for bidirectional prostheses. We characterized the sensations evoked by simultaneous stimulation of median and ulnar nerves (multi-channel configuration) in four transradial amputees who had been implanted with four TIMEs (Transverse Intrafascicular Multichannel Electrodes). The results were compared with the characterization of single-channel stimulation. The sensations were characterized in terms of location, extent, type, and intensity. Combining two or more single-channel configurations caused a linear combination of the sensation locations and types perceived with such single-channel stimulations. Interestingly, this was also true when two active sites from the same nerve were stimulated. When stimulating in multi-channel configuration, the charge needed from each electrode channel to evoke a sensation was significantly lower than the one needed in single-channel configuration (sensory facilitation). This result was also supported by electroencephalography (EEG) recordings during nerve stimulation. Somatosensory potentials evoked by multi-channel stimulation confirmed that sensations in the amputated hand were perceived by the subjects and that a perceptual sensory facilitation occurred. Our results should help the future development of more efficient bidirectional prostheses by providing guidelines for the development of more complex stimulation approaches to effectively restore multiple sensations at the same time.
16 January 2020 in Scientific Reports
Humans rely on their sense of touch to interact with the environment. Thus, restoring lost tactile sensory capabilities in amputees would advance their quality of life. In particular, texture discrimination is an important component for the interaction with the environment, but its restoration in amputees has been so far limited to simplified gratings. Here we show that naturalistic textures can be discriminated by trans-radial amputees using intraneural peripheral stimulation and tactile sensors located close to the outer layer of the artificial skin. These sensors exploit the morphological neural computation (MNC) approach, i.e., the embodiment of neural computational functions into the physical structure of the device, encoding normal and shear stress to guarantee a faithful neural temporal representation of stimulus spatial structure. Two trans-radial amputees successfully discriminated naturalistic textures via the MNC-based tactile feedback. The results also allowed to shed light on the relevance of spike temporal encoding in the mechanisms used to discriminate naturalistic textures. Our findings pave the way to the development of more natural bionic limbs.
15 August 2020 in Journal of NeuroEngineering and Rehabilitation
Background: Recent studies have shown that neural stimulation can be used to provide artificial sensory feedback to amputees eliciting sensations referred on the amputated hand. The temporal properties of the neural stimulation modulate aspects of evoked sensations that can be exploited in a bidirectional hand prosthesis.Methods: We previously collected evidence that the derivative of the amplitude of the stimulation (intra-digit temporal dynamics) allows subjects to recognize object compliance and that the time delay among stimuli injected through electrodes implanted in different nerves (inter-digit temporal distance) allows to recognize object shapes. Nevertheless, a detailed characterization of the subjects’ sensitivity to variations of intra-digit temporal dynamic and inter-digit temporal distance of the intraneural tactile feedback has not been executed. An exhaustive understanding of the overall potentials and limits of intraneural stimulation to deliver sensory feedback is of paramount importance to bring this approach closer and closer to the natural situation. To this aim, here we asked two trans-radial amputees to identify stimuli with different temporal characteristics delivered to the same active site (intra-digit temporal Dynamic Recognition (DR)) or between two active sites (inter-digit Temporal distance Recognition (TR)). Finally, we compared the results achieved for (simulated) TR with conceptually similar experiments with real objects with one subject.Results: We found that the subjects were able to identify stimuli with temporal differences (perceptual thresholds) larger than 0.25 s for DR and larger than 0.125 s for TR, respectively. Moreover, we also found no statistically significant differences when the subjects were asked to identify three objects during simulated ‘open-loop’ TR experiments or real ‘closed-loop’ tests while controlling robotic hand.Conclusions: This study is a new step towards a more detailed analysis of the overall potentials and limits of intraneural sensory feedback. A full characterization is necessary to develop more advanced prostheses capable of restoring all lost functions and of being perceived more as a natural limb by users.
19 November 2020 in Journal of Neural Engineering
Objective. The implantation of intraneural electrodes in amputees has been observed to be effective in providing subjects with sensory feedback. However, this implantation is challenging and time consuming. Surgeons must be especially trained to execute the implantation. Therefore, we aimed at developing a novel peripheral intraneural electrode and insertion mechanism, which could drastically reduce the overall implantation time while achieving a high neural selectivity. Approach. A new insertion method based on hollow microneedles was developed to realize the prompt and effective simultaneous implantation of up to 14 active sites in a transversal manner. Each needle guided two Pt/Ir microwires through the nervous tissue. After the insertion, the microneedles were released, leaving behind the microwires. Each microwire had one active site, which was coated with poly-3,4-ethylenedioxythiophene (PEDOT) to enhance the electrochemical properties. The active sites were characterized by evaluating the impedance, charge storage capacity, and maximum injectable charge. Twelve quick to implant peripheral intraneural electrodes (Q-PINEs) were implanted in four pig sciatic nerves to evaluate the implantation time and neural selectivity. We compared the stimulation of the sciatic nerve with that of its branches. Main results. The average surgical access time was 23 min. The insertion time for 12 electrodes was 6.7 min (std. ±1.6 min). The overall implantation time was reduced by 40.3 min compared to the previously reported values. The Q-PINE system demonstrated a satisfactory performance during in vitro and in vivo characterization. The electrochemical results showed that the PEDOT coating successfully increased the electrochemical parameters of the active sites. Significance. With an average impedance of 1.7 kΩ, a maximum charge level of 76.2 nC could be achieved per active site. EMG recruitment curves showed that 46% of the active sites exhibited selective stimulation of four out of six muscles. The histological analysis indicated that the microwires successfully penetrated the nerve and single fascicles.