Jia-Lun Kwok

Jia-Lun Kwok

Auto-generated profile, based on publicly available information

Jia-Lun Kwok

Tan Tock Seng Hospital

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2023 in European Urology Focus
Verified
Journal Article
Open access
JKJia-Lun Kwok
Jia-Lun Kwok
VCVincent De Coninck
Vincent De Coninck
EVEugenio Ventimiglia
Eugenio Ventimiglia
FPFrédéric Panthier
Frédéric Panthier
MCMariela Corrales
Mariela Corrales
EKEtienne Xavier Keller
Etienne Xavier Keller
Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

15 November 2024 in Urolithiasis
Verified
Journal Article
Closed access
PDF file
JKJia-Lun Kwok
Jia-Lun Kwok
BSBhaskar K Somani
Bhaskar K Somani
KSKemal Sarica
Kemal Sarica
SYSteffi Kar Kei Yuen
Steffi Kar Kei Yuen
MZMarek Zawadzki
Marek Zawadzki
Vineet GauharVineet Gauhar
Vineet Gauhar

4 May 2024 in World Journal of Urology
Verified
Journal Article
Closed access
PDF file
FPfrederic Panthier
frederic Panthier
JKJia-Lun Kwok
Jia-Lun Kwok
DTDavid T. Tzou
David T. Tzou
MMManoj Monga
Manoj Monga
Olivier TraxerOlivier Traxer
Olivier Traxer
EKEtienne Xavier Keller
Etienne Xavier Keller

16 August 2023 in World Journal of Urology
Verified
Journal Article
Open access
PDF file
JKJia-Lun Kwok
Jia-Lun Kwok
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
VCVincent De Coninck
Vincent De Coninck
MCMariela Corrales
Mariela Corrales
ASAlba Sierra
Alba Sierra
EKEtienne Xavier Keller
Etienne Xavier Keller
Purpose: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. Methods: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). Results: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. Conclusion: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.

30 October 2024 in World Journal of Urology
Verified
Journal Article
Closed access
PDF file
ALAlex Lua
Alex Lua
LTLynnette R. L. Tan
Lynnette R. L. Tan
FPfrederic Panthier
frederic Panthier
ASAlba Sierra
Alba Sierra
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
JKJia-Lun Kwok
Jia-Lun Kwok

13 October 2023 in World Journal of Urology
Verified
Journal Article
Open access
PDF file
JKJia-Lun Kwok
Jia-Lun Kwok
Eugenio VentimigliaEugenio Ventimiglia
Eugenio Ventimiglia
VCVincent De Coninck
Vincent De Coninck
FPfrederic Panthier
frederic Panthier
YBYazeed Barghouthy
Yazeed Barghouthy
EKEtienne Xavier Keller
Etienne Xavier Keller
Background: The novel pulsed thulium:yttrium–aluminum–garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. Methods: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). Results: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). Conclusion: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.