Andrzej Krol

Andrzej Krol

Auto-generated profile, based on publicly available information

Andrzej Krol

Department of Radiology and the Department of Pharmacology, State University of New York Upstate Medical University, Syracuse, NY, USA

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2003 in Review of Scientific Instruments
Verified
Journal Article
Open access
LCL. M. Chen
L. M. Chen
PFP. Forget
P. Forget
RTR. Toth
R. Toth
JKJ. C. Kieffer
J. C. Kieffer
AKA. Krol
A. Krol
GMG. Mourou
G. Mourou
We present measurement of characteristic Kα emission from Mo, Ag, and La targets irradiated by a 60 fs, 600 mJ, 10 Hz Ti:sapphire laser pulse at 1017–1019 W/cm2. These x-ray emissions can potentially be used in applications from laser-based hard x-ray sources to x-ray mammography so detailed knowledge of the spectra is required to assess imaging of the figure of merit. We show here that high resolving hard x-ray spectroscopy can be achieved, with resolving powers (E/ΔE) of 60 at 18 keV, with cadmium–zinc–telluride detection system. The Kα conversion efficiency from the laser light to the Kα photon was optimized thanks to this diagnostic and values as high as 2×10−5 were obtained.

9 June 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JGJianfeng Guo
Jianfeng Guo
CSC. Ross Schmidtlein
C. Ross Schmidtlein
AKAndrzej Krol
Andrzej Krol
SLSi Li
Si Li
YLYizun Lin
Yizun Lin
YXYuesheng Xu
Yuesheng Xu
We investigated the imaging performance of a fast convergent ordered-subsets algorithm with subiteration-dependent preconditioners (SDPs) for positron emission tomography (PET) image reconstruction. In particular, we considered the use of SDP with the block sequential regularized expectation maximization (BSREM) approach with the relative difference prior (RDP) regularizer due to its prior clinical adaptation by vendors. Because the RDP regularization promotes smoothness in the reconstructed image, the directions of the gradients in smooth areas more accurately point toward the objective function’s minimizer than those in variable areas. Motivated by this observation, two SDPs have been designed to increase iteration step-sizes in the smooth areas and reduce iteration step-sizes in the variable areas relative to a conventional expectation maximization preconditioner. The momentum technique used for convergence acceleration can be viewed as a special case of SDP. We have proved the global convergence of SDP-BSREM algorithms by assuming certain characteristics of the preconditioner. By means of numerical experiments using both simulated and clinical PET data, we have shown that the SDP-BSREM algorithms substantially improve the convergence rate, as compared to conventional BSREM and a vendor’s implementation as Q.Clear. Specifically, SDP-BSREM algorithms converge 35%-50% faster in reaching the same objective function value than conventional BSREM and commercial Q.Clear algorithms. Moreover, we showed in phantoms with hot, cold and background regions that the SDP-BSREM algorithms approached the values of a highly converged reference image faster than conventional BSREM and commercial Q.Clear algorithms.

1 October 1992 in Journal of Physics and Chemistry of Solids
Verified
Journal Article
Closed access
SWS.C. Woronick
S.C. Woronick
WNWai Tung Ng
Wai Tung Ng
AKA. Król
A. Król
YKYing-Hsien Kao
Ying-Hsien Kao

16 March 2020
Verified
Conference Paper
Closed access
PDF file
HGHoward C. Gifford
Howard C. Gifford
CSC. Ross Schmidtlein
C. Ross Schmidtlein
AKAndrzej Krol
Andrzej Krol
YXYuesheng Xu
Yuesheng Xu
Developing PET reconstruction algorithms with improved low-count capabilities may provide a timely and cost- effective means of reducing radiation dose in promising clinical applications such as immuno-PET that require long-lived radiotracers. For many PET clinics, the reconstruction protocol consists of postsmoothed ordered-sets expectation-maximization (OSEM) reconstruction, but penalized likelihood methods based on total-variation (TV) regularization could substantially reduce dose. We performed a task-based comparison of postsmoothed OSEM and higher-order TV (HOTV) reconstructions using simulated images of a contrast-detail phantom. An anthropomorphic visual-search model observer read the images in a location-known receiver operating characteristic (ROC) format. Acquisition counts, target uptake, and target size were study variables, and the OSEM postfiltering was task-optimized based on count level. A psychometric analysis of observer performance for the selected task found that the HOTV algorithm allowed a two-fold reduction in dose compared to the optimized OSEM algorithm.

30 September 2022 in Journal of Computer Sciences Institute
Verified
Journal Article
Open access
PDF file
AKAndrzej Król
Andrzej Król
TSTomasz Szymczyk
Tomasz Szymczyk
In article, the quality of the following encoders was analyzed: mp3, AAC, wma and OGG Vorbis. An original graphic method was used to carry out the quantitative research. It consists in comparing the number of pixels (representing data) between the spectrogram of a wav file and the spectrograms of files compressed with different codecs and bit rates. It has been shown that the Ogg Vorbis encoder retains the most data from the uncompressed wav sample in all tested bit rates (128KBit / s, 160KBit / s, 320KBit / s).

27 July 2023 in Ból
Verified
Journal Article
Closed access
MBMichał But
Michał But
Magdalena Kocot-KępskaMagdalena Kocot-Kępska
Magdalena Kocot-Kępska
DKDariusz Kosson
Dariusz Kosson
WGWojciech Gola
Wojciech Gola
RDRafał Drwiłła
Rafał Drwiłła
AKAndrzej Król
Andrzej Król