Rafael Palomar

Rafael Palomar

Auto-generated profile, based on publicly available information

Rafael Palomar

The Intervention Centre, Oslo University Hospital, Oslo, Norway

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2019 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Open access
EPEgidijius Pelanis
Egidijius Pelanis
Rahul P K MenonRahul P K Menon
Rahul P K Menon
DADavit L. Aghayan
Davit L. Aghayan
RPRafael Palomar
Rafael Palomar
ÅFÅsmund A. Fretland
Åsmund A. Fretland
BEBjørn von Gohren Edwin
Bjørn von Gohren Edwin
Introduction: In liver surgery, medical images from pre-operative computed tomography and magnetic resonance imaging are the basis for the decision-making process. These images are used in surgery planning and guidance, especially for parenchyma-sparing hepatectomies. Though medical images are commonly visualized in two dimensions (2D), surgeons need to mentally reconstruct this information in three dimensions (3D) for a spatial understanding of the anatomy. The aim of this work is to investigate whether the use of a 3D model visualized in mixed reality with Microsoft HoloLens increases the spatial understanding of the liver, compared to the conventional way of using 2D images. Material and methods: In this study, clinicians had to identify liver segments associated to lesions. Results: Twenty-eight clinicians with varying medical experience were recruited for the study. From a total of 150 lesions, 89 were correctly assigned without significant difference between the modalities. The median time for correct identification was 23.5 [4–138] s using the magnetic resonance imaging images and 6.00 [1–35] s using HoloLens (p < 0.001). Conclusions: The use of 3D liver models in mixed reality significantly decreases the time for tasks requiring a spatial understanding of the organ. This may significantly decrease operating time and improve use of resources.

1 October 2016 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
RPRafael Palomar
Rafael Palomar
FCFaouzi A. Cheikh
Faouzi A. Cheikh
BEBjørn von Gohren Edwin
Bjørn von Gohren Edwin
ABAzeddine Beghdadhi
Azeddine Beghdadhi
OEOle J. Elle
Ole J. Elle
Computer-assisted systems for planning and navigation of liver resection procedures rely on the use of patient-specific 3D geometric models obtained from computed tomography. In this work, we propose the application of Poisson surface reconstruction (PSR) to obtain 3D models of the liver surface with applications to planning and navigation of liver surgery. In order to apply PSR, the introduction of an efficient transformation of the segmentation data, based on computation of gradient fields, is proposed. One of the advantages of PSR is that it requires only one control parameter, allowing the process to be fully automatic once the optimal value is estimated. Validation of our results is performed via comparison with 3D models obtained by state-of-art Marching Cubes incorporating Laplacian smoothing and decimation (MCSD). Our results show that PSR provides smooth liver models with better accuracy/complexity trade-off than those obtained by MCSD. After estimating the optimal parameter, automatic reconstruction of liver surfaces using PSR is achieved keeping similar processing time as MCSD. Models from this automatic approach show an average reduction of 79.59% of the polygons compared to the MCSD models presenting similar smoothness properties. Concerning visual quality, on one hand, and despite this reduction in polygons, clinicians perceive the quality of automatic PSR models to be the same as complex MCSD models. On the other hand, clinicians perceive a significant improvement on visual quality for automatic PSR models compared to optimal (obtained in terms of accuracy/complexity) MCSD models. The median reconstruction error using automatic PSR was as low as 1.03±0.23mm, which makes the method suitable for clinical applications. Automatic PSR is currently employed at Oslo University Hospital to obtain patient-specific liver models in selected patients undergoing laparoscopic liver resection.

1 June 2017 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
RPRafael Palomar
Rafael Palomar
FCFaouzi A. Cheikh
Faouzi A. Cheikh
BEBjørn von Gohren Edwin
Bjørn von Gohren Edwin
ÅFÅsmund Fretland
Åsmund Fretland
ABAzeddine Beghdadi
Azeddine Beghdadi
OEOle J. Elle
Ole J. Elle
For more than a decade, computer-assisted surgical systems have been helping surgeons to plan liver resections. The most widespread strategies to plan liver resections are: drawing traces in individual 2D slices, and using a 3D deformable plane. In this work, we propose a novel method which requires low level of user interaction while keeping high flexibility to specify resections. Our method is based on the use of Bézier surfaces, which can be deformed using a grid of control points, and distance maps as a base to compute and visualize resection margins (indicators of safety) in real-time. Projection of resections in 2D slices, as well as computation of resection volume statistics are also detailed. The method was evaluated and compared with state-of-the-art methods by a group of surgeons (n=5, 5-31 years of experience). Our results show that theproposed method presents planning times as low as state-of-the-art methods (174 s median time) with high reproducibility of results in terms of resected volume. In addition, our method not only leads to smooth virtual resections easier to perform surgically compared to other state-of-the-art methods, but also shows superior preservation of resection margins. Our method provides clinicians with a robust and easy-to-use method for planning liver resections with high reproducibility, smoothness of resection and preservation of resection margin. Our results indicate the ability of the method to represent any type of resection and being integrated in real clinical work-flows.

5 March 2020 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Open access
ATAndrea Teatini
Andrea Teatini
JFJavier Pérez de Frutos
Javier Pérez de Frutos
BEBenjamin Eigl
Benjamin Eigl
EPEgidijus Pelanis
Egidijus Pelanis
DADavit L. Aghayan
Davit L. Aghayan
OEOle Jakob Elle
Ole Jakob Elle
Purpose: This study aims to evaluate the accuracy of point-based registration (PBR) when used for augmented reality (AR) in laparoscopic liver resection surgery. Material and methods: The study was conducted in three different scenarios in which the accuracy of sampling targets for PBR decreases: using an assessment phantom with machined divot holes, a patient-specific liver phantom with markers visible in computed tomography (CT) scans and in vivo, relying on the surgeon’s anatomical understanding to perform annotations. Target registration error (TRE) and fiducial registration error (FRE) were computed using five randomly selected positions for image-to-patient registration. Results: AR with intra-operative CT scanning showed a mean TRE of 6.9 mm for the machined phantom, 7.9 mm for the patient-specific phantom and 13.4 mm in the in vivo study. Conclusions: AR showed an increase in both TRE and FRE throughout the experimental studies, proving that AR is not robust to the sampling accuracy of the targets used to compute image-to-patient registration. Moreover, an influence of the size of the volume to be register was observed. Hence, it is advisable to reduce both errors due to annotations and the size of registration volumes, which can cause large errors in AR systems.

12 May 2017 in International Journal of Parallel Programming
Verified
Journal Article
Open access
PDF file
RPRafael Palomar
Rafael Palomar
JLJuan Gómez Luna
Juan Gómez Luna
FCFaouzi A. Cheikh
Faouzi A. Cheikh
JOJoaquin Olivares
Joaquin Olivares
OEOle J. Elle
Ole J. Elle
Bézier surfaces are mathematical tools employed in a wide variety of applications. Some works in the literature propose parallelization strategies to improve performance for the computation of Bézier surfaces. These approaches, however, are mainly focused on graphics applications and often are not directly applicable to other domains. In this work, we propose a new method for the computation of Bézier surfaces, together with approaches to efficiently map the method onto different platforms (CPUs, discrete and integrated GPUs). Additionally, we explore CPU–GPU cooperation mechanisms for computing Bézier surfaces using two integrated heterogeneous systems with different characteristics. An exhaustive performance evaluation—including different data-types, rendering and several hardware platforms—is performed. The results show that our method achieves speedups as high as 3.12x (double-precision) and 2.47x (single-precision) on CPU, and 3.69x (double-precision) and 13.14x (single-precision) on GPU compared to other methods in the literature. In heterogeneous platforms, the CPU–GPU cooperation increases the performance up to 2.09x with respect to the GPU-only version. Our method and the associated parallelization approaches can be easily employed in domains other than computer-graphics (e.g., image registration, bio-mechanical modeling and flow simulation), and extended to other Bézier formulations and Bézier constructions of higher order than surfaces.

1 January 2010 in Lecture Notes in Computer Science
Verified
Book Chapter
Closed access
PDF file
RPRafael Palomar
Rafael Palomar
JPJose Manuel Palomares
Jose Manuel Palomares
JCJosé M. Castillo
José M. Castillo
JOJoaquin Olivares
Joaquin Olivares
JLJuan Gómez Luna
Juan Gómez Luna