Ouri Cohen

Ouri Cohen

Auto-generated profile, based on publicly available information

Ouri Cohen

Department of Medical Physics Memorial Sloan Kettering Cancer Center New York New York USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
OCOuri Cohen
Ouri Cohen
BZBo Zhu
Bo Zhu
MRMatthew S Rosen
Matthew S Rosen

24 February 2017 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
OCOuri Cohen
Ouri Cohen
MRMatthew S Rosen
Matthew S Rosen

21 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
OCOuri Cohen
Ouri Cohen
VYVictoria Y. Yu
Victoria Y. Yu
KTKathryn R. Tringale
Kathryn R. Tringale
RYRobert J. Young
Robert J. Young
Or PerlmanOr Perlman
Or Perlman
RORicardo Otazo
Ricardo Otazo
Purpose: To develop a clinical CEST MR fingerprinting (CEST‐MRF) method for brain tumor quantification using EPI acquisition and deep learning reconstruction.Methods: A CEST‐MRF pulse sequence originally designed for animal imaging was modified to conform to hardware limits on clinical scanners while keeping scan time under 2 min. Quantitative MRF reconstruction was performed using a deep reconstruction network (DRONE) to yield the water relaxation and chemical exchange parameters. The feasibility of the six parameter DRONE reconstruction was tested in simulations using a digital brain phantom. A healthy subject was scanned with the CEST‐MRF sequence, conventional MRF and CEST sequences for comparison. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter and gray matter. The clinical utility of CEST‐MRF was demonstrated on four patients with brain metastases in comparison to standard clinical imaging sequences. Tumors were segmented into edema, solid core, and necrotic core regions and the CEST‐MRF values compared to the contra‐lateral side.Results: DRONE reconstruction of the digital phantom yielded a normalized RMS error of ≤7% for all parameters. The CEST‐MRF parameters were in good agreement with those from conventional MRF and CEST sequences and previous studies. The mean concordance correlation coefficient for all six parameters was 0.98 ± 0.01 in white matter and 0.98 ± 0.02 in gray matter. The CEST‐MRF values in nearly all tumor regions were significantly different (P = 0.05) from each other and the contra‐lateral side.Conclusion: Combination of EPI readout and deep learning reconstruction enabled fast, accurate and reproducible CEST‐MRF in brain tumors.

9 August 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
Or PerlmanOr Perlman
Or Perlman
KHKai Herz
Kai Herz
MZMoritz Zaiss
Moritz Zaiss
OCOuri Cohen
Ouri Cohen
MRMatthew S Rosen
Matthew S Rosen
CFChristian T. Farrar
Christian T. Farrar

27 August 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
OCOuri Cohen
Ouri Cohen
JPJonathan R. Polimeni
Jonathan R. Polimeni

4 May 2023 in NMR in Biomedicine
Verified
Journal Article
Open access
OCOuri Cohen
Ouri Cohen
RORicardo Otazo
Ricardo Otazo
Chemical exchange saturation transfer (CEST) MRI is a promising molecular imaging technique but suffers from long scan times and complicated processing. CEST was recently combined with magnetic resonance fingerprinting (MRF) to address these shortcomings. However, the CEST‐MRF signal depends on multiple acquisition and tissue parameters so selecting an optimal acquisition schedule is challenging. In this work, we propose a novel dual‐network deep learning framework to optimize the CEST‐MRF acquisition schedule. The quality of the optimized schedule was assessed in a digital brain phantom and compared with alternate deep learning optimization approaches. The effect of schedule length on the reconstruction error was also investigated. A healthy subject was scanned with optimized and random schedules and with a conventional CEST sequence for comparison. The optimized schedule was also tested in a subject with metastatic renal cell carcinoma. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter (WM) and grey matter (GM). The optimized schedule was 12% shorter but yielded equal or lower normalized root mean square error for all parameters. The proposed optimization also provided a lower error compared with alternate methodologies. Longer schedules generally yielded lower error. In vivo maps obtained with the optimized schedule showed reduced noise and improved delineation of GM and WM. CEST curves synthesized from the optimized parameters were highly correlated (r = 0.99) with measured conventional CEST. The mean concordance correlation coefficient in WM/GM for all tissue parameters was 0.990/0.978 for the optimized schedule but only 0.979/0.975 for the random schedule. The proposed schedule optimization is widely applicable to MRF pulse sequences and provides accurate and reproducible tissue maps with reduced noise at a shorter scan time than a randomly generated schedule.