Dheeraj Kumar Palwalia

Dheeraj Kumar Palwalia

Auto-generated profile, based on publicly available information

Dheeraj Kumar Palwalia

Rajasthan Technical University

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2021 in Journal of Interdisciplinary Mathematics
Verified
Journal Article
Closed access
Kuldeep JayaswalKuldeep Jayaswal
Kuldeep Jayaswal
DPD. K. Palwalia
D. K. Palwalia
SKSandeep Kumar
Sandeep Kumar
Robot-assisted surgical procedures have gained much coverage in recent years and favored over manually conducted operations. The medical robots are comprised of manipulators arm that is the multi-degree of freedom positioning devices with a highly non-linear nature to perform various surgical tasks. Due to non-linear effects, robots offer a severe challenge to the control system. Therefore, the control techniques are required for controlling the robots that should be fast enough to accommodate the rapid changes in the system parameters. In this article, the Proportional-Integral-Derivative (PID) controller’s performance has been investigated in trajectory control of the Two-Link Robotic Manipulator (TLRM) for reliable functioning of these robots. Tracking error and Control input factors have been used to investigate the PID controller’s robustness in trajectory control of ‘TLRM.’ Euler’s-lagrange approach has been used for dynamic analysis of ‘TLRM’. This work has been accomplished in the MATLAB®/ Simulink environment.

1 August 2017
Verified
Conference Paper
Closed access
KSKartik Sharma
Kartik Sharma
DPDheeraj Kumar Palwalia
Dheeraj Kumar Palwalia
This paper represents a modified PID control using adaptive fuzzy controller. A critique of performance of conventional PID and Adaptive fuzzy logic tuned PID controller applied to DC motor is provided. A fuzzy logic controller (FLC) is evolved for tuning the three terms of PID controller automatically as per the fuzzy rules. The adaptive FLC produces correction values for conventional PID controller, that are varying online with the system output. The complete system consisting of adaptive fuzzy PID controller along with DC motor model is simulated using MATLAB/Simulink. A comparison of conventional PID with adaptive fuzzy PID controller is demonstrated for reference speed tracking and load disturbance. The results show that, the adaptive fuzzy tuned PID controller provides better dynamic behavior of DC motor with low rise time, low settling time, minimum overshoot and low steady-state error in speed and thus provides superior performance.

23 May 2019 in IETE Journal of Research
Verified
Journal Article
Closed access
SASeema Agrawal
Seema Agrawal
DPD.K. Palwalia
D.K. Palwalia
MKMahendra Kumar
Mahendra Kumar
This paper presents the design and implementation of three-phase four-wire shunt active power filter (SAPF). It consists of insulated gate bipolar transistors, IGBT based current-controlled voltage source inverter (CC-VSI), series coupling inductor and self-supported DC bus. Power electronics based converters and non-linear loads generate waveform-driven power quality issue as harmonics. Three-phase four-wire SAPF mitigates harmonics, compensates for reactive power, neutral current and power factor correction. Conventionally, the positive sequence detection control strategy using phase-locked loop (PLL) is applied as the synchronizing unit vector element to generate reference source currents. Conventional controller tuning process is difficult and fails to perform satisfactorily under supply voltage variation conditions. In this paper, Levenberg-Marquardt back propagation training algorithm based artificial neural network (ANN) controller is proposed to regulate DC link voltage due to its self-adapting and rapid calculation characteristics that allow the controller to handle high nonlinearity and uncertainty in a non-linear system. Weights of a neuron are adapted to minimize total harmonic distortion (THD) of source current under the step, ramp, time series amplitude variation and frequency and amplitude of modulation conditions. The proposed system is modelled in MATLAB/SIMULINK environment and laboratory prototype with dSpace1104 control card is developed. Experimentation results validate the simulated results of the proposed scheme under supply voltage variations for three-phase four-wire distribution system.

1 August 2015
Verified
Conference Paper
Closed access
PKPrakash Kumar
Prakash Kumar
GJGaurav Jain
Gaurav Jain
DPDheeraj Kumar Palwalia
Dheeraj Kumar Palwalia
This paper presents genetic algorithm (GA) based maximum power point tracking (MPPT) for photovoltaic (PV) array integrated with battery storage unit (BSU) as power generation unit in standalone mode. PV generation depends on solar irradiance, site location and environmental factors like temperature, wind and. Thus output of PV output is fluctuating in nature and the addition of non linear load make the situation more critical. GA based MPPT for PV generation works for local optimal solution. DC/DC and boost converter has been used to obtain rated desired rated voltage. BSU acts as secondary source to ensure uninterrupted power supply. A suitable three phase voltage source inverter (VSI), at point of common coupling (PCC), provides regulated power supply. Boost converters incorporating proportional controller (PI) increases PV voltage up to 400V. Conventionally used perturb and observe (PO) algorithm has been used for comparative study. Controlled pulse width modulated (PWM) switching pulse for converter unit and single section LC filter at output terminal eliminates harmonic components. To exhibit the system compatibility resistive, reactive, asynchronous induction motor and nonlinear load has been switched at different instants for variable solar irradiance and temperature.

13 October 2018 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
Kuldeep JayaswalKuldeep Jayaswal
Kuldeep Jayaswal
DPD. K. Palwalia
D. K. Palwalia
DC-DC converters preserve or control the output DC voltage. Due to parasitic constituents such as leakage capacitance of both diode and inductor, and transformer leakage inductance, DC-DC converters mostly operate on rigid switching conditions which result in high switching losses. These parasitic constituents affect the dc-dc converter’s operational reliability, instigate electromagnetic interference issues and limit the converter’s operation at higher frequency operations. In this paper, resonant or soft-switch approach has been employed to improve the operating performance and design-oriented principle investigations have been carried out for overcoming the issues of parasitic constituents in 24-12V DC-DC step-down (buck) converter. This paper divulges the analysis and Matlab Simulation results for 24-12V buck converter based on resonant or soft-switching approach.

4 October 2015 in Journal of Renewable Energy
Verified
Journal Article
Open access
PDF file
PKPrakash Kumar
Prakash Kumar
DPDheeraj Kumar Palwalia
Dheeraj Kumar Palwalia
Power extension of grid to isolated regions is associated with technical and economical issues. It has encouraged exploration and exploitation of decentralized power generation using renewable energy sources (RES). RES based power generation involves uncertain availability of power source round the clock. This problem has been overcome to certain extent by installing appropriate integrated energy storage unit (ESU). This paper presents technical review of hybrid wind and photovoltaic (PV) generation in standalone mode. Associated components like converters, storage unit, controllers, and optimization techniques affect overall generation. Wind and PV energy are readily available, omnipresent, and expected to contribute major future energy market. It can serve to overcome global warming problem arising due to emissions in fossil fuel based thermal generation units. This paper includes the study of progressive development of standalone renewable generation units based on wind and PV microgrids. Power extension of grid to isolated regions is associated with technical and economical issues. It has encouraged exploration and exploitation of decentralized power generation using renewable energy sources (RES). RES based power generation involves uncertain availability of power source round the clock. This problem has been overcome to certain extent by installing appropriate integrated energy storage unit (ESU). This paper presents technical review of hybrid wind and photovoltaic (PV) generation in standalone mode. Associated components like converters, storage unit, controllers, and optimization techniques affect overall generation. Wind and PV energy are readily available, omnipresent, and expected to contribute major future energy market. It can serve to overcome global warming problem arising due to emissions in fossil fuel based thermal generation units. This paper includes the study of progressive development of standalone renewable generation units based on wind and PV microgrids.