Abolfazl Abedi

Abolfazl Abedi

Auto-generated profile, based on publicly available information

Abolfazl Abedi

Department of Electrical Engineering, Shahid Beheshti University, Tehran 19834, Iran

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MTMajid Taghavi
Majid Taghavi
HLHamid Latifi
Hamid Latifi
GPGholam Mohammad Parsanasab
Gholam Mohammad Parsanasab
AAAbolfazl Abedi
Abolfazl Abedi
HNHamed Nikbakht
Hamed Nikbakht
MPMohammad Hosein Poorghadiri
Mohammad Hosein Poorghadiri
This paper is a report on the design and fabrication of a dual-axis micro-opto-electro-mechanical system (MOEMS) accelerometer. The device consists of a proof mass (PM) suspended by four L-shaped springs. Two Fabry-Pérot (FP) cavities are formed between the cross-sections of the PM and the ends of two cleaved optical fibers in perpendicular directions (the X and Y axes). The acceleration causes the proof mass to move in the reverse direction relative to the applied acceleration. The sensor is fabricated by a silicon-on-insulator wafer. The fabricated sensor is characterized both by spectral monitoring and power measurements in the range of ±1 g. The results of spectral measurements show 3.23 nm/g (g=9.81 m/s2: gravity constant) and 3.19 nm/g to the applied acceleration along the X and Y axes, respectively. Moreover, the obtained resolutions for the two directions of X and Y are 309 μg and 313 μg, respectively. Besides, the sensitivity of the sensor in power measurements is 550 mV/g and 528 mV/g in the X and Y directions, respectively. The sensor also possesses the resonant frequencies of 1382.5 Hz and 1398.6 Hz in the X and Y axes, respectively, in the range of ±1 g. The maximum cross-axis sensitivities obtained for this sensor are below 0.19% for each pair of X, Y, and Z axes. This value is fewer than the cross-axis sensitivity of most micro electro-mechanical systems without any post processing. This small value is a result of insensitivity of the FP spectrum to the lateral displacements of the PM.

23 January 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
MTMajid Taghavi
Majid Taghavi
HLHamid Latifi
Hamid Latifi
GPGholam Mohammad Parsanasab
Gholam Mohammad Parsanasab
AAAbolfazl Abedi
Abolfazl Abedi
HNHamed Nikbakht
Hamed Nikbakht
MSMohammad Javad Sharifi
Mohammad Javad Sharifi
This paper presents the design, fabrication, and characterization of a SU-8 four L-shaped beams optical MEMS (MOEMS) accelerometer based on a Fabry-Perot(FP) interferometer. An applied acceleration causes a displacement of the proof mass and changes the cavity of FP resonator. Fabrication process has been simplified such that only two photolithography steps are required and SU-8 is used for both the structural body and the sacrificial layer. To prevent the sacrificial layer from being exposed to UV light, a thin copper layer is coated by physical vapor deposition technique between the two SU-8 layers. The sensor chip consists of a proof mass which is suspended by four L-shaped springs. The movement of the proof mass in response to acceleration is detected by a FP cavity formed between the proof mass and the cleaved end of a single mode optical fiber. The fabricated sensor has a sensitivity of 12.5 μW/g and resonant frequency of 1872 Hz in the range of ±1g.

8 December 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
SMSajad Abolpour Moshizi
Sajad Abolpour Moshizi
AAAbolfazl Abedi
Abolfazl Abedi
MSMajid Sanaeepur
Majid Sanaeepur
CPChristopher John Pastras
Christopher John Pastras
ZHZhao Jun Han
Zhao Jun Han
MAMohsen Asadnia
Mohsen Asadnia
Monitoring human respiratory patterns is of great importance as it gives essential information for various medical conditions, e.g. sleep apnoea syndrome and chronic obstructive pulmonary disease and asthma, etc. Herein, we have developed a polymeric airflow sensor based on nanocomposites of vertically grown graphene nanosheets (VGNs) with polydimethylsiloxane (PDMS) and explored their applications in monitoring human respiration. The sensing performance of the VGNs/PDMS nanocomposite was characterized by exposing to a range of airflow rates (20–130 l min −1 ), and a linear performance with high sensitivity and low response time (mostly below 1 s) was observed. To evaluate the experimental results, finite-element simulation models were developed in the COMSOL Multiphysics package. The piezoresistive properties of VGNs/PDMS thin film and fluid–solid interaction were thoroughly studied. Laser Doppler vibrometry measures of sensor tip displacement closely approximated simulated deflection results and validated the dynamic response of the sensor. By comparing the proposed sensor and some other airflow sensors in the literature, it is concluded that the VGNs/PDMS airflow sensor has excellent features in terms of sensor height, detection range and sensitivity. The potential application of the VGNs/PDMS airflow sensor in detecting the respiration pattern of human exercises like walking, jogging and running has been demonstrated.

1 March 2020 in Superlattices and Microstructures
Verified
Journal Article
Closed access
AAAbolfazl Abedi
Abolfazl Abedi
MSMohammad Javad Sharifi
Mohammad Javad Sharifi

14 December 2017 in Journal of Computational Electronics
Verified
Journal Article
Closed access
PDF file
AAAbolfazl Abedi
Abolfazl Abedi
MSMohammad Javad Sharifi
Mohammad Javad Sharifi

30 May 2018 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
AAAbolfazl Abedi
Abolfazl Abedi
MSMohammad Javad Sharifi
Mohammad Javad Sharifi
In this paper, the effect of electron-phonon scattering on the negative differential resistance of graphene nanoribbon p-n junctions is investigated. The results show that the optical phonon scattering, due to inelasticity, significantly increases the valley current such that the peak-to-valley ratio decreases several orders of magnitude compared to ballistic approximation. It also shifts up the valley voltage. The former effect manifests itself more in structures with a smaller band gap and better ballistic characteristics. We show that it remains remarkable in different lengths of the transition region and severely affects the performance of the device. The results also show that phonon scattering plays a significant role even in ultrascaled nanodevices.