22 July 2026 in Acta of Bioengineering and Biomechanics
Purpose: Growth-guidance spinal systems are used in children with progressive spinal deformity to reduce repeated surgical lengthening while allowing continued spinal growth. Their long-term biomechanical behaviour under cyclic loading remains insufficiently characterised. This study assessed whether diamond-like carbon coating of rods and sliding screws affects axial stiffness and local kinematics in a growth-guidance spinal system. Methods: Twelve porcine Th11–L7 spine specimens were assigned to three groups: non-instrumented control, non-coated titanium alloy instrumentation, and instrumentation with diamond-like carbon-coated components. Specimens underwent 100,000 cycles of axial compression. Axial stiffness was evaluated after 100 and 100,000 cycles. Vertebral range of motion from Th12 to L6 was measured using rigid body markers, and local rod–screw interface displacements were assessed using three-dimensional digital image correlation. Results: Stiffness increased similarly in all groups up to approximately 80,000 cycles. After 100,000 cycles, construct stiffness was approximately 6% lower in diamond-like carbon coated instrumentation than in non-coated titanium alloy instrumentation. In the coated construct, segmental mobility at Th12–L1 and L5–L6 remained closer to the non-instrumented condition, whereas non-coated titanium alloy instrumentation showed reduced motion at these levels. Digital image correlation demonstrated time-dependent differences in local rod–screw interface kinematics between coated and non-coated constructs. Conclusions: Diamond-like carbon coating did not increase overall construct stiffness during cyclic axial compression, but it modified local mechanical behaviour and was associated with preservation of segmental mobility at selected levels. Further studies should determine whether these effects are maintained under multi-axis loading and in long-term tribological conditions.
31 March 2025 in Chirurgia Narządów Ruchu i Ortopedia Polska
Introduction. The growing interest in non-fusion surgical procedures for idiopathic scoliosis (IS) raises the question regarding the optimal indications. This study aimed to analyze the results of VBT surgery applied to various IS curvatures. Material and methods. Twenty-four patients, aged 11-14yrs, mean 13.0 ± 1.0, underwent surgical correction of IS using VBT technique. The curve pattern was Lenke1 (N = 17), Lenke3 (N = 3), and Lenke5 (N = 4). Thoracic Cobb was 45.0° ± 6.0° in Lenke1. Lumbar Cobb was 50.0° ± 12.0° in Lenke3 and Lenke5. Risser sign ranged from 0 (N = 10) to 4 (N = 2), median=1. Sanders score ranged from 2 (N = 1) to 7 (N = 6), median = 5. VBT surgery was performed using a single tether in the thoracic (N = 17) or double tether in the lumbar spine (N = 7). Endoscopic or mini open approach was used for the procedure. At the thoracic level, the instrumentation covered 6 vertebrae (mean 6 ± 1; range 5 to 8) while at the lumbar level, it covered 5 vertebrae, extending distally to either L3 or L4. Pre-, post- and FU evaluations were performed for radiological parameters. Results. The recovery was uneventful. Clinical correction was satisfactory with balanced trunk and reduction of rib or lumbar prominence. The spinal mobility was preserved. The radiological correction was 20.0° ±6.0°, range 9.0°–48.0°, and 38.0° ± 8.0°, range 27.0°–48.0°, in the thoracic and the lumbar spine, respectively. In Lenke1, the spontaneous correction of the non-instrumented lumbar spine was 26.0° ± 6.0°, range 18.0° to 37.0°. In two Lenke3 patients the lumbar VBT was completed with thoracic posterior spinal fusion (PSF). Tether breakage was observed in 5 cases at the follow-up of 12–46 months (mean 28), without requiring re-operation. Failure to achieve correction led to PSF conversion in two Lenke1 patients. Surgical technique modification is proposed for severe lumbar curves. Conclusion. The diverse range of Lenke types reflected priorities: mini-invasive thoracic correction vs. preservation of lumbar mobility. Successful correction of various scoliosis angles and patterns could be achieved without major complications. Technical modification for severe lumbar scoliosis is proposed.