Seonghwan Yee

Seonghwan Yee

Auto-generated profile, based on publicly available information

Seonghwan Yee

Radiology Harvard Medical School Boston Massachusetts USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JTJiayi Tang
Jiayi Tang
DTDaiki Tamada
Daiki Tamada
JNJon‐Fredrik Nielsen
Jon‐Fredrik Nielsen
JSJitka Starekova
Jitka Starekova
JHJulius Frederik Heidenreich
Julius Frederik Heidenreich
DHDiego Hernando
Diego Hernando
Purpose: To develop and validate a vendor‐agnostic, motion‐insensitive proton‐density fat‐fraction (PDFF) quantification method. Methods: Flip‐angle‐modulated (FAM) 2D chemical‐shift‐encoded (CSE) MRI for PDFF quantification was implemented in both the vendor‐agnostic platform Pulseq (“Pulseq‐FAM”) and one vendor‐specific platform (“GE‐specific FAM”). These implementations were distributed to four sites with twelve MR systems of three vendors (Siemens/GE/Philips) and field strengths (0.55T/1.5T/3T). A sequentially‐shipped 16‐vial phantom (PDFF = 0%–30%/T1 water = 200–1400 ms) underwent confounder‐corrected PDFF mapping with commercial 3D‐CSE methods and GE‐specific FAM as available on each system, and Pulseq‐FAM on every system. To assess bias, phantom PDFF measurements were compared to reference. Between‐system variance was evaluated with linear mixed‐effects modeling. Different volunteers were also imaged at each site to assess free‐breathing PDFF mapping feasibility. A prospective single‐site volunteer study was also conducted. Adult patients and children were imaged with breath‐held 3D‐CSE and free‐breathing GE‐specific and Pulseq‐FAM. Radiologists evaluated images for overall quality and motion artifacts. To assess bias, Pulseq‐FAM PDFF measurements were compared to 3D‐CSE and GE‐specific FAM. Test–retest repeatability was assessed by re‐imaging after repositioning. Between‐field‐strength reproducibility was assessed at 1.5T and 3.0T. Results: In the multi‐center study, Pulseq‐FAM showed reduced T1‐bias and between‐system variability versus 3D‐CSE in phantom PDFF measurements, and free‐breathing feasibility in volunteers. In the single‐site volunteer study ( N = 57), Pulseq‐FAM improved image quality and motion artifacts versus 3D‐CSE ( p < 0.01). Pulseq‐FAM showed excellent agreement with 3D‐CSE (95% limits‐of‐agreement (LoA) = 3.4% PDFF) and GE‐specific FAM (LoA = 2.0%). Pulseq‐FAM showed excellent repeatability (repeatability coefficient (RC) = 1.6% PDFF) and between‐field‐strength reproducibility (reproducibility coefficient (RDC) = 2.4%) versus 3D‐CSE (RC = 2.7%/RDC = 3.4%; differences p < 0.05). Conclusion: Pulseq‐FAM enables accurate, reproducible, vendor‐agnostic, and motion‐insensitive PDFF quantification in adults and children.

2 April 2026 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
AHAzadeh Hajati
Azadeh Hajati
CCChen-Hua Chiang
Chen-Hua Chiang
SBSittaya Buathong
Sittaya Buathong
ATAzadeh Tabari
Azadeh Tabari
SYSeonghwan Yee
Seonghwan Yee
SHSusie Y. Huang
Susie Y. Huang