Alfonso Santiago

Alfonso Santiago

Auto-generated profile, based on publicly available information

Alfonso Santiago

Department of Computer Applications in Science and Engineering, Barcelona Supercomputing Centre (BSC)

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2018 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
ASAlfonso Santiago
Alfonso Santiago
JAJazmín Aguado‐Sierra
Jazmín Aguado‐Sierra
MZMiguel Zavala‐Aké
Miguel Zavala‐Aké
RDRuben Doste
Ruben Doste
SGSamuel Gómez
Samuel Gómez
MVMariano Vázquez
Mariano Vázquez

1 January 2021 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Open access
FMFrancesca Margara
Francesca Margara
Zhinuo Jenny WangZhinuo Jenny Wang
Zhinuo Jenny Wang
FLFrancesc Levrero-Florencio
Francesc Levrero-Florencio
ASAlfonso Santiago
Alfonso Santiago
MVMariano Vázquez
Mariano Vázquez
BRBlanca Rodriguez
Blanca Rodriguez
Human-based computational modelling and simulation are powerful tools to accelerate the mechanistic understanding of cardiac patho-physiology, and to develop and evaluate therapeutic interventions. The aim of this study is to calibrate and evaluate human ventricular electro-mechanical models for investigations on the effect of the electro-mechanical coupling and pharmacological action on human ventricular electrophysiology, calcium dynamics, and active contraction.

1 April 2020 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Open access
FLF. Levrero-Florencio
F. Levrero-Florencio
FMF. Margara
F. Margara
EZErnesto Zacur
Ernesto Zacur
Alfonso Bueno-OrovioAlfonso Bueno-Orovio
Alfonso Bueno-Orovio
Zhinuo Jenny WangZhinuo Jenny Wang
Zhinuo Jenny Wang
BRB. Rodriguez
B. Rodriguez
The human heart beats as a result of multiscale nonlinear dynamics coupling subcellular to whole organ processes, achieving electrophysiologically-driven mechanical contraction. Computational cardiac modelling and simulation have achieved a great degree of maturity, both in terms of mathematical models of underlying biophysical processes and the development of simulation software.

13 June 2022 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
ASAlfonso Santiago
Alfonso Santiago
CBConstantine Butakoff
Constantine Butakoff
BEBeatriz Eguzkitza
Beatriz Eguzkitza
RGRichard A. Gray
Richard A. Gray
KMKaren May-Newman
Karen May-Newman
MVMariano Vázquez
Mariano Vázquez
Background: Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. Methods: The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow Q A o a v g , maximum aortic root flow Q A o m a x , average LVAD flow Q V A D a v g , and maximum LVAD flow Q V A D m a x ); (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Results: Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. Conclusions: This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

1 June 2012
Verified
Conference Paper
Closed access
Carlos A. CifuentesCarlos A. Cifuentes
Carlos A. Cifuentes
ABAriel Braidot
Ariel Braidot
LRLuis Rodriguez
Luis Rodriguez
MFMelisa Frisoli
Melisa Frisoli
ASAlfonso Santiago
Alfonso Santiago
ANAnselmo Frizera Neto
Anselmo Frizera Neto
This paper presents a new tool for assessment and therapy in post-stroke upper-limb rehabilitation and a new wireless sensor technology to enhance rehabilitation robotics based on the ZigBee network of wearable Inertial Measurement Units (IMU) and Surface Electromyography (sEMG) sensor nodes. These sensor nodes will allow the measurement of kinematic and electrical muscle activity of patients in continuous therapy motion over all body segments as a Body Sensor Network (BSN). The IMU Sensor design was based on a direction-cosine-matrix DCM. The system validation was achieved with an optical motion tracking system in which cameras and IMU sensors recorded upper limb positions simultaneously during a standard gesture of reaching and grasping. The comparison between elbow flexion-extension angle in reaching and grasping movements obtained from both techniques shows equivalence. The analysis of IMU data signals for several movements demonstrates high repeatability intra and inter-subjects.

1 May 2019
Verified
Conference Paper
Open access
OROleksandr Rudyy
Oleksandr Rudyy
MGMarta Garcia-Gasulla
Marta Garcia-Gasulla
FMFilippo Mantovani
Filippo Mantovani
ASAlfonso Santiago
Alfonso Santiago
RSRaul Sirvent
Raul Sirvent
MVMariano Vazquez
Mariano Vazquez
Since the appearance of Docker in 2013, container technologies for computers have evolved and gained importance in cloud data centers. However, adoption of containers in High-Performance Computing (HPC) centers is still under discussion: on one hand, the ease in portability is very well accepted; on the other hand, the performance penalties and security issues introduced by the added software layers are often under scrutiny. Since very little evaluation of large production HPC codes running in containers is available, we provide in this paper a comparative study using a production simulation of a biological system. The simulation is performed using Alya, which is a computational fluid dynamics (CFD) code optimized for HPC environments and enabled to run multiphysics problems. In the paper, we analyze the productivity advantages of adopting containers for large HPC codes, and we quantify performance overhead induced by the use of three different container technologies (Docker, Singularity and Shifter) comparing it to native execution. Given the results of these tests, we selected Singularity as best technology, based on performance and portability. We show scalability results of Alya using singularity up to 256 computational nodes (up to 12k cores) of MareNostrum4 and present a study of performance and portability on three different HPC architectures (Intel Skylake, IBM Power9, and Arm-v8).