With the increasing integration of power electronic converters into the power system, the interactions between converters and their adjacent transmissions bring emerging oscillation issues. A new type of sub- and super-synchronous interactions (S2SI) between STATCOMs and the weak AC/DC grid were detected in China Southern Grid. Field measurements as well as simulation studies have revealed that the various factors contributing to the S2SI include the number of online STATCOMs, the strength of the AC system (in terms of effective short circuit ratio), the status of series compensation and the loading level of the HVDC. The mechanism of such oscillations have been clarified and it is caused by the S2SI between STATCOMs and weak AC grids, where sub- and super-synchronous components are involved in a coupled way. To fully represent such a coupling effect, the concept of sub- and super-synchronous coupled impedance model, or S2SC-IM, is proposed and developed in order to establish a stability criterion for the S2SI. The results show good consistence among theoretical analysis, electromagnetic simulations and field measurements. Therefore, the effectiveness of the developed models and the stability criterion has been well verified.
29 April 2019 in IEEE Transactions on Industrial Electronics
Series-connected-based offshore wind farms can eliminate bulky central offshore converters, transformers, and platforms. In a series-connected-based offshore wind farm, the DC voltage of the converters should be changed within a large range to control the DC link voltage (grid side) and maximize wind power acquisition (generator side). In this study, the full-bridge-based modular multilevel converter (FB-MMC) is proposed as grid- and generator-side converters. The DC voltage of the FB-MMC can vary in a large range because the full-bridge submodule (FBSM) is used. The control method of the FB-MMC in a series-connected-based offshore wind farm is different from those of traditional ones. The DC current control and capacitor voltage balance control are proposed in this study, with which the FB-MMC can operate normally in the series connected offshore wind farm. Moreover, the capacitor ripple voltage in the generator-side FB-MMC is studied. The result shows that the capacitor in the FBSM can be designed in rated power and frequency, and it will be feasible when the power and frequency decrease. Simulation and experiment results verify the feasibility of the proposed configuration and the corresponding control algorithm.
24 December 2019 in IEEE Transactions on Industrial Electronics
A large high-voltage direct current (HVDC) reactor is required in modular multilevel converter (MMC) projects to realize DC fault current limiting (FCL). This condition may result in adverse effects on MMC control dynamics and oscillation and instability of HVDC systems. In this study, a virtual reactor (VR) control strategy is proposed to reduce a fixed large HVDC reactor. The VR characteristic of MMCs is revealed and analyzed as a controlled reactor, and the inductance of this reactor can be directly controlled by the discharge degree of submodule capacitors. A VRFCL control strategy in which VR can effectively limit DC fault current and substitute the fixed HVDC reactor is proposed accordingly. Simulation and experimental results verify the proposed control strategy. The adoption of the proposed strategy can eliminate the undesirable effect caused by an HVDC reactor, and the SM capacitor voltage can be reserved well. In addition, fault clearance time and fault energy dissipation can be reduced. The proposed VRFCL control is beneficial for MMCs to safely ride through DC fault in a continuous operation manner.
10 September 2018 in IEEE Transactions on Power Electronics
Utilization of negative voltage states substantially reduces the energy storage requirements of a full-bridge sub-module-based modular multilevel converter (FB-MMC). This study provides a detailed analysis of the capacitor voltage ripple and energy storage requirement reduction effects of the FB-MMC by utilizing negative voltage states. The analytical expressions of capacitor voltage ripple following the change in negative voltage state factor (NVSF) are derived. Results show that the capacitor voltage ripple reduction effects using negative voltage states is strongly correlated with the operated power factor angle. In addition, the second-order ripple component must be considered to increase the accuracy in evaluating the voltage ripple reduction effects. This study defines the energy storage reduction factor (ESRF) to indicate the level at which the energy storage requirement can be minimized by selecting an appropriate NVSF for a given permitted operating range of the power factor angle. The curve of the ESRF following the change in the permitted operating range of the power factor angle was calculated. The analytical method and the evaluation results for the capacitor voltage and energy storage reduction effects of the FB-MMC using negative voltage states are verified on the basis of the simulation and experimental results.
1 June 2020 in CSEE Journal of Power and Energy Systems
The WDD project is the world’s first multi-terminal UHVDC project that combines LCC-HVDC and VSC-HVDC. Such station-to-station hybrid UHVDC systems can make full use of the technical advantages of VSC to ride through the faults of AC system and improve the voltage support capability of power grids at the receiving end. One of the key challenges for the success of this project is to ensure that both the designs of the main equipment and the control functions meet the expected performance indices and technical specifications. For this, before being taken into operation, experimental tests based on a physical prototype followed by onsite commissioning are essential to verify the safety and reliability of equipment and system in various operating conditions. This article aims to introduce the experimental platform, key physical prototype tests based on the platform, and the key tests undertaken during system onsite commissioning.