Shukai Xu

Shukai Xu

Auto-generated profile, based on publicly available information

Shukai Xu

Electric Power Research Institute of China Southern Power Grid (EPRI of CSG)

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JWJuanjuan Wang
Juanjuan Wang
MHMenghua Huang
Menghua Huang
CFChuang Fu
Chuang Fu
HLHuan Li
Huan Li
SXShukai Xu
Shukai Xu
XLXiaohua Li
Xiaohua Li

8 November 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Can WangCan Wang
Can Wang
JXJiexiong Xu
Jiexiong Xu
Xuewei PanXuewei Pan
Xuewei Pan
WGWenming Gong
Wenming Gong
ZZZhe Zhu
Zhe Zhu
SXShukai Xu
Shukai Xu
Similar to the conventional three-phase parallel-connected MMC (PC-MMC), the three-phase series-connected MMC (SC-MMC) is a strong potential solution for high-voltage direct current (HVDC) applications. The study of SC-MMC focuses on the control strategy, neglecting its small-signal dynamics, not to mention its stability when interacting with the AC grid. Work on small-signal modeling of MMC is limited to parallel-connected configurations. SC-MMC differs from PC-MMC in structure and harmonic content; hence, it is necessary to establish an accurate model of SC-MMC according to its own characteristics. This paper introduces the circuit and control of SC-MMC and compares it with PC-MMC. Multi-harmonic linearization is used to establish the AC impedance model of SC-MMC over the whole control system, including the third harmonic suppression controller. We take a PC-MMC station of the Wudongde HVDC project as a benchmark to explore the potential application of SC-MMC when constructing new HVDC stations to extract power from an existing DC transmission corridor. The strengths and weaknesses of SC-MMC in HVDC applications are discussed, and it is compared to PC-MMC with regard to the impedance characteristic.

29 April 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GGGaopeng Guo
Gaopeng Guo
QSQiang Song
Qiang Song
BZBiao Zhao
Biao Zhao
HRHong Rao
Hong Rao
SXShukai Xu
Shukai Xu
WLWenhua Liu
Wenhua Liu
Series-connected-based offshore wind farms can eliminate bulky central offshore converters, transformers, and platforms. In a series-connected-based offshore wind farm, the DC voltage of the converters should be changed within a large range to control the DC link voltage (grid side) and maximize wind power acquisition (generator side). In this study, the full-bridge-based modular multilevel converter (FB-MMC) is proposed as grid- and generator-side converters. The DC voltage of the FB-MMC can vary in a large range because the full-bridge submodule (FBSM) is used. The control method of the FB-MMC in a series-connected-based offshore wind farm is different from those of traditional ones. The DC current control and capacitor voltage balance control are proposed in this study, with which the FB-MMC can operate normally in the series connected offshore wind farm. Moreover, the capacitor ripple voltage in the generator-side FB-MMC is studied. The result shows that the capacitor in the FBSM can be designed in rated power and frequency, and it will be feasible when the power and frequency decrease. Simulation and experiment results verify the feasibility of the proposed configuration and the corresponding control algorithm.

4 December 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LYLimin Yang
Limin Yang
YLYhaohua Li
Yhaohua Li
ZLZixin Li
Zixin Li
PWPing Wang
Ping Wang
SXShukai Xu
Shukai Xu
RGRuifeng Gou
Ruifeng Gou
Modular multilevel converters (MMCs) have been widely used in VSC-HVDC, and the capacity of MMCs has reached 1000 MW. The accurate calculation and theoretical analysis of the loss attract more and more attention, especially in the high power applications. This paper presents a simplified analytical calculation model of average power loss for MMC based on the RMS and absolute values of the arm current. In this model, the analytical expressions of the conduction loss and the switching loss are derived in terms of the whole arm of MMC rather than a single submodule. It avoids the effect of the complexity of its switching pattern on the calculation accuracy of the model. The explicit expressions of the presented model show the relationship between the loss and the voltage balancing methods and the main variables of MMC directly in comparison with the conventional loss evaluation methods. PSCAD/EMTDC simulation and experimental results of the $\pm$350 kV/1000 MW MMC in the Luxi Back-to-Back DC Asynchronous Networking Project verify the correctness and the accuracy of the proposed simplified calculation model.

24 December 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XLXiaoqian Li
Xiaoqian Li
ZLZiming Li
Ziming Li
BZBiao Zhao
Biao Zhao
CLChao Lu
Chao Lu
QSQiang Song
Qiang Song
ZZZhe Zhu
Zhe Zhu
A large high-voltage direct current (HVDC) reactor is required in modular multilevel converter (MMC) projects to realize DC fault current limiting (FCL). This condition may result in adverse effects on MMC control dynamics and oscillation and instability of HVDC systems. In this study, a virtual reactor (VR) control strategy is proposed to reduce a fixed large HVDC reactor. The VR characteristic of MMCs is revealed and analyzed as a controlled reactor, and the inductance of this reactor can be directly controlled by the discharge degree of submodule capacitors. A VRFCL control strategy in which VR can effectively limit DC fault current and substitute the fixed HVDC reactor is proposed accordingly. Simulation and experimental results verify the proposed control strategy. The adoption of the proposed strategy can eliminate the undesirable effect caused by an HVDC reactor, and the SM capacitor voltage can be reserved well. In addition, fault clearance time and fault energy dissipation can be reduced. The proposed VRFCL control is beneficial for MMCs to safely ride through DC fault in a continuous operation manner.

7 September 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JMJiufang Man
Jiufang Man
XXXiaorong Xie
Xiaorong Xie
SXShukai Xu
Shukai Xu
CZChangyue Zou
Changyue Zou
CYCongqi Yin
Congqi Yin
Recently, a high-frequency resonance (HFR) incident has been captured in an actual HVDC project of China Southern Power Grid, which is regarded as a new stability issue caused by the interaction between the modular multilevel converter (MMC) and the weak ac grid. To investigate this event, this paper proposes a stability analysis method based on the frequency-coupling impedance model (FCIM). First, the FCIMs of the MMC and the ac grid are established in abc-frame individually with the frequency coupling effect of the MMC taken into account. Next, they are aggregated into a two-by-two impedance matrix by numerical calculation. Then, based on the aggregated FCIM, a criterion is developed to locate the HFR modes and to evaluate their stability. Finally, the results obtained from FCIM-based analysis are verified by electromagnetic transient (EMT) simulations as well as the field measurements.