1 November 2021 in Plasma Sources Science and Technology
As an emerging and extraordinary plasma source, the bipolar-pulse high power impulse magnetron sputtering (BP-HiPIMS) has promising prospects and wide industrial applications. In this paper, an effort to optimize the plasma flux and energy in BP-HiPIMS via auxiliary anode and solenoidal coil was made. This novel plasma source contains two types of auxiliary anode voltage (direct current and pulse) and one type of solenoidal coil current (direct current) to synergistically enhance the plasma generation and diffusion by electric field and magnetic field together. Systematic evaluations of discharge characteristics demonstrate that applying auxiliary anode voltage and coil magnetic field effectively contribute to a reduction in delay time of target current onset and increase in peak amplitude of target current, which are beneficial for improving plasma generation and target sputtering. The complex plasma dynamics are diagnosed by Langmuir probe and optical emission spectroscopy, and simulated by particle-in-cell/Monte Carlo collision approach. These comprehensive investigations on plasma parameters demonstrate that the plasma density, emission intensity of the metal ions, substrate current density, and ionization fraction of sputtered target particles have been improved with the increase of coil current. The observations of the increase in excitation temperature T exc of Ar atoms, and more extended high-energy tails in electron energy distribution function curves imply that the plasma can be significantly heated by the auxiliary anode. Combining the simulation results and theoretical model proposed in the last sub-content, the diffusion and transport mechanism of charged-particles in complex electric and magnetic fields are discussed. From the theoretical analysis, the qualitative relation between the plasma density and coil current is well consistent with the measurements of electron density obtained by Langmuir probe. These evidences all support the idea that the plasma flux and energy can be enhanced in BP-HiPIMS discharge via auxiliary anode and solenoidal coil together.
1 February 2022 in Plasma Sources Science and Technology
Investigating the ion dynamics in the emerging bipolar pulse high power impulse magnetron sputtering (BP-HiPIMS) discharge is necessary and important for broadening its industrial applications. Recently, an optimized plasma source operating the BP-HiPIMS with an auxiliary anode and a solenoidal coil is proposed to enhance the plasma flux and energy, named as ACBP-HiPIMS (‘A’-anode, ‘C’-coil). In the present work, the temporal evolutions of the ion velocity distribution functions (IVDF) in BP-HiPIMS and ACBP-HiPIMS discharges are measured using a retarding field energy analyser (RFEA). For the BP-HiPIMS discharge, operated at various positive pulse voltages U + , the temporal evolutions of IVDFs illustrate that there are two high-energy peaks, E 1 and E 2 , which are both lower than the applied U + . The ratio of the mean ion energy E i,mean to the applied U + is around 0.55–0.6 at various U + . In ACBP-HiPIMS discharge, the IVDF evolution shows three distinguishable stages which has the similar evolution trend with the floating potential V f on the RFEA frontplate: (i) the stable stage with two high-energy peaks ( E 2 and E 3 with energy respectively lower and higher than the applied U + amplitude) when the floating potential V f is close to the applied positive pulse voltage; (ii) the transition stage with low-energy populations when the V f drops by ∼20 V within ∼10 μ s; and (iii) the oscillation stage with alternating E 2 and E 3 populations and ever-present E 1 population when the V f slightly decreases until to the end of positive pulse. The comparison of IVDFs in BP-HiPIMS and ACBP-HiPIMS suggests that both the mean ion energy and high-energy ion flux have been effectively improved in ACBP-HiPIMS discharge. The formation of floating potential drop is explored using the Langmuir probe which may be attributed to the establishment of anode double layer structure. The acceleration of ion at the double layer boundary is analysed using a theoretical model, in this way to clarify the oscillation in IVDF evolutions in ACBP-HiPIMS discharge.
1 September 2022 in Plasma Sources Science and Technology
As an emerging and extraordinary plasma source, bipolar pulsed high power impulse magnetron sputtering (BP-HiPIMS) discharge has been widely concerned by academia and industry due to the ability to control the deposited ion energy. In the present work, with the intension of increasing the high-energy ion fraction and flux during deposition, the BP-HiPIMS is operated together with a solenoidal coil installed in front of the target. This intension is achieved by applying a pulsed coil current so that the ions generated during the high-power negative pulse can be manipulated to diffuse towards substrate and then arrive at the substrate surface during the positive pulse. Systematic investigations of discharge characteristics and plasma parameters for Ti target discharge in Ar gas have been made, illustrating that applying a pulsed coil current prior to the positive pulse onset for ∼50 μ s is an optimal selection to obtain a larger fraction of high-energy ions. The complex plasma dynamics has also been explored using the particle-in-cell/Monte Carlo collision approach. To verify the statements realized by plasma measurements, the Ti films have been deposited on a floating Si substrate, whose microstructure and surface morphology are characterized by field emission scanning electron microscope and atomic force microscope. The deposition illustrates that applying a pulsed coil current prior to the positive pulse onset for ∼50 μ s can prepare a thicker, denser, and smoother Ti film. The link between the plasma parameters and film microstructure is studied using the molecular dynamics simulations which show that the high-energy ions contribute to optimizing the adatom diffusion and mobility on growing film surface, which is more beneficial to get a smaller grain size and decrease the film surface roughness.
1 October 2024 in Plasma Sources Science and Technology
As an emerging ion acceleration plasma source, the bipolar-pulse high power impulse magnetron sputtering (BP-HiPIMS) discharge has been widely studied by academia and industry due to its ability to adjust the ion kinetic energy. Formation of the double layer (DL) potential structure during the BP-HiPIMS positive pulse is vital for accelerating ions, but its structural characteristics are still unclear. In this work, to understand the DL characteristics affected by various discharge parameters, the evolution of plasma potential V p and ion energy in BP-HiPIMS discharge with copper target has been investigated systematically using an emissive probe and mass spectrometer together. Spatial plasma potential measurements show that the DL is established in front of the target during the positive pulse, whose boundary potential drop U DL to accelerate ions can be increased to ∼60 V at a lower operating gas pressure (p= 0.6 Pa) and a higher applied positive pulse voltage (U + = 200 V). The ignition onset time of DL after applying the positive pulse can be shortened to ∼25 μs by decreasing the gas pressure and increasing the positive pulse voltage or negative pulse duration. After DL ignition, a group of high-energy copper ions with energy higher than the surrounding plasma potential can be recognized in the ion energy distribution function curves in the downstream plasma. This result illustrates that the copper ions can be ionized in the high-potential plasma region and be accelerated by the DL boundary potential drop. In addition, a global current balance model of the DL in BP-HiPIMS is developed, which suggests that the U DL can be well adjusted by increasing the positive pulse voltage U + especially for U + > 200 V as verified by the experimental potential measurements. All results suggest that the copper particles play an important role in the formation of DL and the DL plays an important role in accelerating copper ions.
28 March 2025 in Journal of Alloys and Compounds
1 February 2025 in Plasma Sources Science and Technology
Investigation of the plasma decay mechanism from energy and density temporal/spatial evolutions together is important and urgent in the novel bipolar-pulse high power impulse magnetron sputtering (BP-HiPIMS) discharge for adjusting the deposited ion energy flux. In this work, temporal and spatial characteristics of the electron energy distribution function (EEDF) have been systematically investigated using a time-resolved (250 ns) Langmuir probe to obtain the plasma decay process clearly. The plasma decay has a typical characteristic of three-step during the positive pulse. At the initial period of positive pulse (Step 1), the existence of hot electrons and potential gradient force can accelerate the plasma density decay even up to ∼1015 m−3 μs−1. As the electron energy are cooled to several eVs, the plasma decay is dominated by the density gradient pressure with an ion sound velocity (0.5–0.7 kms−1), which can increase the downstream electron density (Step 2). As the redistribution of plasma density in the whole discharge domain, the electron density decay is exponential (Step 3) and the maximum decay rate is near the target due to the higher density gradient, while the maximum electron temperature is away from the target. Along the density gradient diffusion, the relation between electron density and temperature in BP-HiPIMS satisfies the well-known Boltzmann relation n e = n 0exp(eV p/kT e). In addition, the EEDF characteristics in the BP-HiPIMS operated with an auxiliary anode and solenoid coil have also been investigated in this work, where an increase in electron density and plasma diffusion mobility has been observed after applying the anode or solenoid coil. These temporal and spatial EEDFs allow us to understand the complex plasma physics in the emerged BP-HiPIMS discharge clearly, especially with the view of high-energy and low-energy electron loss and balance.