To enhance the cutting performance of TiAlSiN coated cemented carbide tools by inserting Ti interlayers and to explore their mechanism, TiAlSiN/Ti multilayer coatings with different Ti thicknesses, including 0 nm, 25 nm, 50 nm, 100 nm, and 150 nm, were deposited onto cemented carbide (WC-10 wt%, Co) substrates by high power impulse magnetron sputtering (HiPIMS). The microstructure, hardness, grain orientation, residual stress, adhesion, and toughness of those coatings were measured, and the cutting performance against Inconel 718 was analyzed. Meanwhile, finite element method (FEM) indentation simulations were performed to gain detailed insight into the effects of Ti interlayer thickness on mechanical properties of TiAlSiN/Ti multilayer coatings. Results demonstrated that mechanical properties of TiAlSiN multilayer coatings were significantly changed after the Ti interlayer was introduced, and the multilayer coating #M2 with 25 nm Ti layer showed the excellent toughness and adhesion without sacrificing hardness too much. As Ti interlayer thickness increased, both toughness and adhesion decrease owing to the plastic mismatch between individual layers, and these changes were discussed detailedly with finite element method. Moreover, the result of the cutting experiment also revealed that the tool flank wear Vb can be reduced by the multilayer structure. This improvement is believed to be due to the increasing toughness, which alleviated the damage caused by the continuous impact load of hard phases generated by Inconel 718 during cutting.
The investigation of plasma dynamics and optimization of target particle diffusion are particularly important and urgent in the recently emerging bipolar-pulse high-power impulse magnetron sputtering (BP-HiPIMS) discharge. In this paper, a novel approach, in which an external auxiliary anode was installed in front of the sputtering target, was proposed to optimize electric field distribution and guide particle diffusion, named as AABP-HiPIMS. A positive pulse voltage was applied to the auxiliary anode in synchronization with the target positive pulse voltage, which was achieved by connecting the target and auxiliary anode through a diode in series. Advantageously, no additional power supply needs to be provided in AABP-HiPIMS. The discharge characteristics of this new plasma source were investigated in detail. A theoretical model was successfully built to reveal the transformation process of the target current from the net ion current to the net electron current by systematically analyzing the collapsing process of the target sheath and charged-particle movement in E × B fields. The optimization of ion diffusion was investigated by diagnosing plasma parameters using a Langmuir probe and emissive probe together. The measurements illustrate that, as expected, the electron density in AABP-HiPIMS during the positive pulse phase has been effectively increased ∼2.5 times on average compared to that in the conventional BP-HiPIMS. Correspondingly, the plasma potential distribution illustrates that the potential gradient pointing to the auxiliary anode centre is more beneficial for control of ion diffusion and to enhance ion flux towards the downstream. Additionally, for better selection of the magnetron process parameters, the characteristic time of plasma decay during the positive pulse was estimated using the Bohm diffusion theory. The rough calculation of flight time for electrons from z = 35 to 95 mm was ∼70 μ s in BP-HiPIMS and ∼50 μ s in AABP-HiPIMS, respectively. The effects of negative pulse duration and positive pulse amplitude on plasma parameters were investigated. Measurements of plasma potentials suggest that adopting a relatively short duration negative pulse and a slightly higher amplitude positive pulse, as well as employing the externally applied auxiliary anode, are the optimum choices for improving both the flux and energy of deposited particles when preparing films on the floating substrate.
1 November 2021 in Plasma Sources Science and Technology
As an emerging and extraordinary plasma source, the bipolar-pulse high power impulse magnetron sputtering (BP-HiPIMS) has promising prospects and wide industrial applications. In this paper, an effort to optimize the plasma flux and energy in BP-HiPIMS via auxiliary anode and solenoidal coil was made. This novel plasma source contains two types of auxiliary anode voltage (direct current and pulse) and one type of solenoidal coil current (direct current) to synergistically enhance the plasma generation and diffusion by electric field and magnetic field together. Systematic evaluations of discharge characteristics demonstrate that applying auxiliary anode voltage and coil magnetic field effectively contribute to a reduction in delay time of target current onset and increase in peak amplitude of target current, which are beneficial for improving plasma generation and target sputtering. The complex plasma dynamics are diagnosed by Langmuir probe and optical emission spectroscopy, and simulated by particle-in-cell/Monte Carlo collision approach. These comprehensive investigations on plasma parameters demonstrate that the plasma density, emission intensity of the metal ions, substrate current density, and ionization fraction of sputtered target particles have been improved with the increase of coil current. The observations of the increase in excitation temperature Texc of Ar atoms, and more extended high-energy tails in electron energy distribution function curves imply that the plasma can be significantly heated by the auxiliary anode. Combining the simulation results and theoretical model proposed in the last sub-content, the diffusion and transport mechanism of charged-particles in complex electric and magnetic fields are discussed. From the theoretical analysis, the qualitative relation between the plasma density and coil current is well consistent with the measurements of electron density obtained by Langmuir probe. These evidences all support the idea that the plasma flux and energy can be enhanced in BP-HiPIMS discharge via auxiliary anode and solenoidal coil together.
TiAlSiN coatings were deposited on YT 15 cemented carbide substrate by reactive direct current magnetron sputtering (DCMS) in a Plasma Immersion Ion Implantation and Deposition (PIII&D) system. The pre-implantation step and the coating deposition were carried out in the same experimental facility. In this article the effects of pre-implantation of several different elements (N, C, and O) were investigated. The adhesion strength, hardness, micro-structure, element concentration, depth profile, and the formation of coatings after the PIII experiments were characterized by a wide variety of techniques such as Rockwell indentation, scratch test, nano-indentation measurement, X-ray diffraction, energy dispersive spectroscopy, and Auger electron spectroscopy. The results showed that the adhesive strength of TiAlSiN coatings was significantly improved on samples pre-implanted with N and O whereas only slightly improved with pre-implantation of C. Additionally, the microstructure and mechanical properties of the TiAlSiN coatings were also altered through pre-implantation. The improved adhesion could be explained by the grain refinement and surface energy enhancement of the substrate by pre-implantation.