Anton Beláň

Anton Beláň

Auto-generated profile, based on publicly available information

Anton Beláň

Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 81 219 Bratislava, Slovakia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2022 in Processes
Verified
Journal Article
Open access
PDF file
JBJozef Bendík
Jozef Bendík
Matej CenkýMatej Cenký
Matej Cenký
BCBoris Cintula
Boris Cintula
ABAnton Beláń
Anton Beláń
ŽEŽaneta Eleschová
Žaneta Eleschová
PJPeter Janiga
Peter Janiga
In recent years, the emerging fear of an energy crisis in central Europe has caused an increased demand for distributed energy resources (DER), especially small photovoltaic rooftop installations up to 10 kWp. From a technical point of view, distributed PV in low-voltage networks is associated with the risk of power quality violation, overvoltage, voltage unbalance, harmonics, and violation of the thermal limit of phase conductors, neutral conductors, and transformers. Distribution system operators (DSO) are currently in a position to determine the amount of installed PV power for which reliable and safe network operation is ensured, also known as the photovoltaic hosting capacity (PVHC). The presented study describes a stochastic methodology for PVHC estimation and uses it to analyze a typical LV rural network in the Slovak Republic. Detailed and precise calculations are performed on the 4-wire LV model with accurate results. In this study, we, thus, profoundly analyze the problems with voltage violation, unbalanced voltage energy losses, and the thermal loading effect of increasing PV penetration. The results show that overvoltage events are the main factor limiting the PVHC in LV systems. This conclusion is in accordance with the experience of the DSO in the Slovak and Czech Republic. Subsequently, the study focuses on the possibilities of increasing PVHC using those tools typically available for DSO, such as changes in PV inverter power factors and no-load tap changer transformers. The results are compared with those derived from similar analyses, but we ultimately find that the proposed solution is problematic due to the high variability of approaches and boundary conditions. In conclusion, the paper discusses the issue of the acceptable risk of overvoltage violation in the context of PVHC and lowering losses in LV networks.

16 September 2023 in Data in Brief
Verified
Journal Article
Open access
Matej CenkýMatej Cenký
Matej Cenký
JBJozef Bendík
Jozef Bendík
BCBoris Cintula
Boris Cintula
PJPeter Janiga
Peter Janiga
ŽEŽaneta Eleschová
Žaneta Eleschová
ABAnton Beláň
Anton Beláň
This article presents a comprehensive dataset comprising average 15-minute values of active and reactive energy consumption in 1000 anonymized households located in the Slovak Republic, a central European country, throughout the year 2016. The dataset provides a valuable resource for researchers and practitioners interested in analysing energy consumption patterns at the individual household level within the unique context of Central Europe. Privacy concerns are addressed through anonymization techniques, ensuring the dataset's compliance with ethical considerations and privacy regulations. However, ZIP code information is included for each household. Researchers can confidently analyze the data without compromising the households' confidentiality. The dataset offers significant opportunities for researchers to explore energy consumption patterns, develop targeted energy management strategies, and contribute to the advancement of sustainable energy practices.

3 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
BCBoris Cintula
Boris Cintula
ŽEŽaneta Eleschová
Žaneta Eleschová
Matej CenkýMatej Cenký
Matej Cenký
PJPeter Janiga
Peter Janiga
JBJozef Bendík
Jozef Bendík
ABAnton Beláň
Anton Beláň
Calculation and measurement of the overhead power lines electrical parameters is common practice in today’s electrical engineering industry; however, there is very little data to actually compare these two approaches because measured data in such detail are mostly unavailable for academic purposes. Based on the very detailed model of an overhead power line in MATLAB Simulink environment and conducted experimental measurement, this article specifically covers the exact evaluation of the impedance of the investigated overhead power line. Differences between calculation and experimental measurement are shown and discussed accordingly, where, surprisingly, the biggest deviation was observed in the positive resistance parameter. The connection between different measurement techniques (multiple single-phase and three-phase methods), as well as the power line asymmetry reflection in the impedance matrix is explained as well as compared to expected values from the computations. The complete mathematical approach for electrical parameters evaluation from different measurement methods is explained step-by-step, and the final equations are introduced for each method. Proposed methods of obtaining the electrical parameters of the power line are then concluded as the ones with great accuracy and wide usage in practical applications. It shows the great importance of correct input data for the electrical parameters’ theoretical computations and the need to know the measurement methodology and apparatus perfectly to process the measured data and interpret them correctly.

13 January 2023 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Matej CenkýMatej Cenký
Matej Cenký
JBJozef Bendík
Jozef Bendík
BCBoris Cintula
Boris Cintula
PJPeter Janiga
Peter Janiga
ABAnton Beláň
Anton Beláň
ŽEŽaneta Eleschová
Žaneta Eleschová

21 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
ABAnton Beláň
Anton Beláň
BCBoris Cintula
Boris Cintula
Matej CenkýMatej Cenký
Matej Cenký
PJPeter Janiga
Peter Janiga
JBJozef Bendík
Jozef Bendík
AŠAdam Šimurka
Adam Šimurka
The current transformation of power systems is aiming towards distributed source integration and general decentralization. Renewable energy sources and support of local energy supply create conditions for widespread use of new technologies and smart grids. As the electrical grids become more electrically independent, the importance of frequency control will rise. Stability of the system in such cases is no longer only relying on rotating inertia of generators as in the centralized grid. This known scenario has already been analyzed by many with computational models for optimal safety precautions of the grid. This paper aims to update the common home appliance frequency characteristics through measurements and compare them to those currently used. These devices were divided into two groups: general categorization and light sources. Subsequently, the frequency sensitivity coefficients were evaluated and analyzed home appliances were sorted into three categories according to the size of their frequency sensitivity coefficient values: positive, negative, and no effect. The results were compared with studies aimed at evaluating the static load characteristics. A simplified simulation of the frequency control, presented in the discussion section, was carried out to determine the consequences of the newly measured characteristics and concludes the paper.

1 January 2015 in Energy & Environment
Verified
Journal Article
Closed access
FJFrantišek Janíček
František Janíček
ŠMŠčepánek Michal
Ščepánek Michal
ABAnton Beláň
Anton Beláň
ICIng. Igor Chrapčiak
Ing. Igor Chrapčiak
STSchrack Technik
Schrack Technik
PCPeter Chochol
Peter Chochol
The Slovak Republic (SR) is an inland country in the middle of Europe with a total area of 49 035 km2and population 5.45 million people. The capital is Bratislava and the country is member of the European Union. The annual electric energy consumption is 28 862 GWh and production is 28 135 GWh (2011). The average electricity consumption in the household sector is 2.5 MWh per year and the average price is 140 EUR/MWh. The electric energy distribution in Slovakia is assured by 3 regional distribution companies covering 2.35 million points of supply. The annual volume of supplied electric energy by distribution companies via HV and LV networks has reached the level of 18 000 GWh. The area of electric energy distribution is regulated by the independent authority Regulatory Office for Network Industries. The Slovak Republic has approved the Concept of Energy Efficiency, having the primary target to achieve gradual lowering of energy demands to the level of European Union. In the years 2001 – 2010, the total volume of final electric energy consumption was reduced by 6%, i.e. by 7 TWh. Construction of intelligent metering systems is another step to achieve a higher energy efficiency, according to the Concept of Energy Efficiency of SR and according to the Directive of the European Parliament and Council 2009/72/EC of July 13, 2009. The intelligent metering systems are perceived as a part of a smart grid construction, conducted already for several years by main manufacturers, operators of the transmission and distribution systems. Automated meter reading (AMR) based solutions have covered all significant points of supply in the wholesale category, in a total number of 50 000 with consumption monitoring reaching the total volume of approximately 50% of consumed electric energy. At the LV voltage level, most of the points of supply have an electromechanical or static meter installed. The Regulatory Office for Network Industries in cooperation with the Ministry of Economy assessed the analysis of deploying intelligent metering systems for the LV level positively, and joined other European countries, such as Germany, Poland, Hungary, Slovenia, Romania, Bulgaria, Greece, Latvia, Portugal and Belgium. The economic assessment of the AMI deployment project in Slovakia and implementation of intelligent metering systems is assumed within the years 2013 to 2020. The project covers the points of supply with annual consumption above 4 MWh, representing approximately 23% of all assumed points of supply at the LV voltage level. The target number of points of supply, expected to have the intelligent meters installed by 2020, is approximately 600 000, with consumption representing approximately 53% of the total annual consumption of electric energy at the LV voltage level. The rollout scope could be affected by the planned revaluation of CBA. The implementation is based on several types of intelligent 1 and 3 phase meters, according to the supply point type, which are differentiated by their functional specification in basic, advanced and special ones. The total assumed annual economic benefits following the implementation of intelligent metering system and installation of intelligent meters at the LV level are expected to be around EUR 36.16 per one point of supply. The biggest benefit will belong to the end customer. The CAPEX figures per one point of supply should be around EUR 131.00 and the operating costs OPEX should be EUR 8.23 per annum. Most of the problems in specification and architecture design are caused the current extent of standardization, legislation and return of investment. In order to verify the technical and economic assumptions, a pilot project will be launched in the years 2013 – 2014 covering 1% of the total final volume, i.e. approximately 6 000 points of supply. The rollout itself is planned in the years to follow. Until the end of 2016, it will cover the consumers having the annual consumption more than 15 MWh with a maximum reserve capacity in the point of supply at least 30 kW, or at least 45 A and until the end of 2020 the consumers having the annual consumption more than 4 MWh with maximum reserve capacity in the point of supply less than 30 kW or 45 A.