27 October 2021 in IEEE Transactions on Industrial Electronics
The circuit parameters mismatch of input-parallel output-parallel (IPOP) dual active bridge (DAB) converter modules will cause power imbalances of the system. To solve this problem, in this article, we present a simple sensorless current sharing control based on dual-phase-shift (DPS) modulation method. First, the full process operation mode of IPOP DAB is analyzed. Then, the power balance mechanism of the IPOP DAB converter is discussed, and a sensorless current sharing control method is proposed. The core principle of the proposed method is based on the perturbation algorithm to estimate the parameter mismatches of each DAB cell. Once the parameter mismatches are known, the phase shifts that achieve current sharing are calculated. The implementation scheme based on CAN Bus is given, and sensitivity and stability analysis of the proposed method is conducted. Finally, the simulation and experimental results verify the effectiveness of the proposed control strategy.
27 May 2022 in IEEE Transactions on Power Electronics
The common inductor and common capacitor current sharing technologies with excellent current sharing capabilities and low cost have attracted a lot of attention in recent years. However, these methods have certain limitations when dealing with multiple resonate parameters mismatches of multiphase LLC converters. To solve this problem, this article proposes a unified common inductor and common capacitor scheme. First, the existing common inductor and common capacitor methods are reviewed. Based on the first harmonic approximation (FHA) analysis method, the limitations of these schemes are analyzed, and we find that the current sharing performance is not well when the multiresonant parameters are mismatched, which will cause the one-phase to bear more power, even overpowered and damaged. To realize a better current sharing of multiphase LLC modules, a unified common inductor and common capacitor method is proposed in this article, where the series resonant inductors and resonant capacitors in each LLC converter are connected in parallel. The current sharing performance of the proposed method is analyzed by the FHA analysis method, and the proof-of-concept prototype with a 480 W 24 V two-phase LLC converter was built to verify the effectiveness of the proposed method. Simulation and experimental results show that the current sharing error of the proposed method is 2.1% under half load and 0.9% under full load.
10 August 2023 in IEEE Transactions on Power Electronics
The existing four-elemental matrix transformer terminal integration methods lay out rectifier devices (SRs) outside the magnetic core, resulting in additional footprint area or core loss problems. To address these limitations, this letter proposes an internal magnetic core terminal integration method by excavating the center area of the upper and lower magnetic plates and integrating SRs with the secondary winding. First, the center area of the upper and lower magnetic plates is verified to have a low magnetic density, so excavating this area has a small effect on the magnetic flux density of the core. Then, the transformer loss model of the proposed magnetic core is built, and the PCB winding integration with this core is implemented. Finally, two 480W LLC prototypes were built to verify the superiority of the proposed method by comparing efficiency and temperature.
28 April 2023 in IEEE Transactions on Power Electronics
Current balancing performance of the existing grouping transformer's secondary windings (GTSW) method is determined by leakage inductance mismatches. Nevertheless, the transformer's leakage inductance parasitic parameters in practice are difficult to accurately design, especially in high-frequency occasions, causing a large current-sharing error between phases. To solve this problem, this article proposes an improved GTSW current-sharing method. By ingeniously changing the connection mode of transformer's secondary windings, the influence of secondary leakage inductance mismatch on current sharing performance is eliminated, and the current sharing performance of secondary side is significantly improved. The first harmonic approximation analysis method is used to establish the current sharing error model of the primary side and secondary side of the system. Furthermore, the current sharing performance of the existing GTSW method and the proposed method is quantitatively compared. Then, the effectiveness of the proposed method is verified by simulation and the two-phase 480 W experiment results. Finally, some great performances of the proposed method are discussed, such as advantages in high-frequency applications, no effect of parasitic capacitance on the current sharing performance, the potential scalability in the case of other dc–dc topology and high current scenarios, and modular expansion capabilities.
6 August 2024 in IEEE Transactions on Power Electronics
In the energy storage scenarios of low-voltage-high-current, the three-switch push-pull full-bridge bidirectional dc–dc converter (TPFBC) can be used with the characteristics of fewer number of power switches and low cost compared with dual-active-bridge. Nevertheless, it has the disadvantages of high voltage stress and difficulty in realizing full-load zero-voltage switching. To address these problems, an improved active clamp push-pull full-bridge bidirectional dc–dc converter is proposed in this article, which is composed by adding a clamping capacitor to the TPFBC. The proposed topology can realize the voltage clamping function, so the low-voltage and low-cost devices are allowed to be used in this circuit. Besides, a minimum inductor current effective value control strategy is proposed in this article to reduce the inductance loss, and the power switches can achieve soft switching in a wide load range. Then, the forward and backward operation characteristics are symmetrical with a smooth switching of charging and discharging modes under the PWM plus phase shift modulation strategy. In addition, the transformer winding voltage has a higher number of levels, and it is closer to the sine wave enabling it to reduce reactive power and improve operation efficiency. The operation principle, detail characteristic analysis, control strategy, power losses analysis, and parametric design are presented, and a 500-W experimental prototype is built to verify the effectiveness.
1 December 2020 in Energy Reports