A novel zero-voltage-switching (ZVS) bidirectional dc/dc converter for energy storage system is proposed in this paper. The primary side is the improved push-pull topology adding one switch to achieve ZVS and the secondary side is a full-bridge topology. Compared with the conventional dual-active-bridge (DAB) dc/dc converter, the proposed converter applies a three-switch topology substituting for the full-bridge structure in the low-voltage side of transformer with seven switches in all. With minimum switch, the cost of the driving circuit can also be saved and the stability of the whole system can be better guaranteed. Most of all, the proposed converter can realize the advantages of DAB, such as bidirectional power transmission and ZVS. Besides, it has no increase in power losses and transformer volume reaching relatively the same effect of the DAB. The operation principles, comparative analysis, design, and control strategy are presented in detail. A 500-W laboratory prototype is built to verify the theoretical analysis and demonstrate the validity of the converter.
8 November 2019 in IEEE Transactions on Power Electronics
Paralleling silicon carbide (SiC) MOSFETs is a cost-effective solution for increasing pulse current rating. However, the device mismatch and asymmetrical circuit layout would lead to imbalance current of the paralleled SiC MOSFETs. In this letter, we propose a passive approach that a coupled inductor instead of the conventional resonant inductor, which is used for a resonant pulsed power converter. The coupled inductor enables even current sharing of the parallel SiC MOSFETs, and also helps with pulse width adjustment, which leads to a simplified system without complex control circuit compared with in the active solution. The configuration of the proposed topology, operating principle, imbalance current limitation mechanism, and design guidelines are fully discussed and presented. Additionally, experiments are carried out to verify the analysis and effectiveness of the proposed solution. The proposed method can be extended to the scenario with more than two parallel SiC MOSFETs.
1 June 2021 in IEEE Transactions on Power Electronics
In this paper, a sensorless current balance method for a multiple phase interleaved boost converter is proposed. Balanced current can help an interleaved boost converter prevent imbalanced heat distribution and inductor saturation, as well as improve the output voltage performance and overall system efficiency. This paper analyzes the relationship equations between the periodic output voltage ripple and the phase current balance status. In the proposed method, the current sensor is eliminated, and only one voltage sensor on the output capacitor side is needed to monitor the output voltage information. The proposed current sensorless control method estimates the phase current distribution status according to the periodic output voltage peak ripple value and adjusts the phase current distribution status by changing the gate drive signal duty cycle of each phase MOSFET. To validate the proposed method, a PSIM simulation model and a two-phase interleaved boost converter test bench are set up, and the experiment waveforms verify the effectiveness of the proposed method.
27 October 2021 in IEEE Transactions on Industrial Electronics
The circuit parameters mismatch of input-parallel output-parallel (IPOP) dual active bridge (DAB) converter modules will cause power imbalances of the system. To solve this problem, in this article, we present a simple sensorless current sharing control based on dual-phase-shift (DPS) modulation method. First, the full process operation mode of IPOP DAB is analyzed. Then, the power balance mechanism of the IPOP DAB converter is discussed, and a sensorless current sharing control method is proposed. The core principle of the proposed method is based on the perturbation algorithm to estimate the parameter mismatches of each DAB cell. Once the parameter mismatches are known, the phase shifts that achieve current sharing are calculated. The implementation scheme based on CAN Bus is given, and sensitivity and stability analysis of the proposed method is conducted. Finally, the simulation and experimental results verify the effectiveness of the proposed control strategy.
3 September 2020 in IEEE Transactions on Transportation Electrification
DC-link capacitors are one kind of reliability-critical component in traction inverters. As such, it is essential to evaluate the degradation characteristics of dc-link capacitors. Accelerated life testing is an effective and standard method to evaluate the capacitors' lifetime and degradation mechanisms. Therefore, an accelerated life testing method for dc-link capacitors in three-phase inverter applications is proposed in this article. In order to reproduce the same encountered stress, exactly reflecting the real condition for the capacitor under test, a three-phase inverter with the capacitor under test and a three-phase balanced inductor load are used as the evaluation circuit. Due to the employment of the inductor load, the power consumption of the inverter can be reduced, while the full-scale current rating can be maintained so that the capacitor under test is subjected to the practical ripple current stress. In order to estimate a capacitor's capacitance with high accuracy, an effective and direct condition monitoring method, which is based on the proposed evaluation circuit, is also proposed in this article. By injecting an ac voltage into the dc link, the ac current and voltage components in the dc-link capacitor are generated. Then, the capacitance mathematical model can be developed by analyzing the injected voltage component and the resultant current component. As the proposed method only requires estimating the parameters from the input voltage and current, there is no need to install additional capacitor current sensors, which are usually difficult to install. Moreover, the amount of monitored and processed data can be reduced. Thus, the proposed method is easy to implement for accelerated life testing in practice. In addition, experiments are carried out to verify the analysis and effectiveness of the proposed solution.
27 May 2022 in IEEE Transactions on Power Electronics
The common inductor and common capacitor current sharing technologies with excellent current sharing capabilities and low cost have attracted a lot of attention in recent years. However, these methods have certain limitations when dealing with multiple resonate parameters mismatches of multiphase LLC converters. To solve this problem, this article proposes a unified common inductor and common capacitor scheme. First, the existing common inductor and common capacitor methods are reviewed. Based on the first harmonic approximation (FHA) analysis method, the limitations of these schemes are analyzed, and we find that the current sharing performance is not well when the multiresonant parameters are mismatched, which will cause the one-phase to bear more power, even overpowered and damaged. To realize a better current sharing of multiphase LLC modules, a unified common inductor and common capacitor method is proposed in this article, where the series resonant inductors and resonant capacitors in each LLC converter are connected in parallel. The current sharing performance of the proposed method is analyzed by the FHA analysis method, and the proof-of-concept prototype with a 480 W 24 V two-phase LLC converter was built to verify the effectiveness of the proposed method. Simulation and experimental results show that the current sharing error of the proposed method is 2.1% under half load and 0.9% under full load.