Giwon Kang

Giwon Kang

Auto-generated profile, based on publicly available information

Giwon Kang

School of Civil and Environmental Engineering, Pusan National University, Busan, 46241, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Environmental Research
Verified
Journal Article
Closed access
GKGiwon Kang
Giwon Kang
KCKyungil Cho
Kyungil Cho
JSJiyoon Shin
Jiyoon Shin
SLSoodong Lee
Soodong Lee
SLSeung-Bok Lee
Seung-Bok Lee
CKChanghyuk Kim
Changhyuk Kim

23 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SSSeo Hee Seo
Seo Hee Seo
YOYong-Hwan Oh
Yong-Hwan Oh
SJSang-Hee Jo
Sang-Hee Jo
TKTae-Hun Kim
Tae-Hun Kim
GKGiwon Kang
Giwon Kang
CKChanghyuk Kim
Changhyuk Kim
The electron beam (EB)-absorption flue gas treatment system was developed to enhance the removal efficiency of gaseous air pollutants such as NOx and SO2. However, EB irradiation can simultaneously cause secondary particulate formation through gas-to-particle conversion. In this study, the EB-absorption system was improved by integrating an electrostatic spray (ES) to remove secondary particles generated during flue gas treatment. The flue gas cleaning performance of the EB-absorption-ES hybrid system was systematically evaluated using different additive types (NaOH and NH4OH) and gas-to-additive stoichiometric ratios (1:2, 1:5, and 1:10). Increasing the stoichiometric ratio increased the removal efficiencies of gaseous pollutants. NO2 removal efficiency increased up to 83.3% with the stoichiometric ratio, while SO2 removal remained above 85% under all experimental conditions. However, this EB-induced flue gas treatment simultaneously promoted secondary particle formation within the size range of 150-250 nm. Both total number and volume concentrations of the secondary particles increased with the stoichiometric ratio. Compared with NaOH, NH4OH showed substantially greater secondary particle formation due to additional gas-phase neutralization involving volatilized NH3. The downstream ES chamber significantly captured secondary particles generated during EB-based flue gas treatment, and its particle removal performance improved with increasing applied voltage. MPPD modeling further indicated substantially reduction of potential respiratory deposition of additive-derived particles after ES addition. Ion species analysis strongly supported the effectiveness of ES in capturing secondary particles formed during the EB-absorption process.