25 March 2018 in Geophysical Research Letters
19 April 2018 in Journal of Geophysical Research: Space Physics
The blue luminous events (BLEs) recorded by ISUAL (Imager of Sprites and Upper Atmospheric Lightning) radiate unambiguous middle ultraviolet to blue emissions (230–450 nm) but contain dim red emissions (623–754 nm). The BLE appears to be dot‐like on one ISUAL image with an integration time of 29 ms. A few BLEs develop upward into blue jets/starters or type II gigantic jets (GJs). The associated sferics of the BLEs in the extremely low frequency to very low frequency band and in the low‐frequency band exhibit similar patterns to the narrow bipolar events (NBEs) identified in the very low frequency and low‐frequency band. The ISUAL BLEs are conjectured to be the accompanied light emissions of the NBEs. Both upward and downward propagating current obtained from the associated sferics of the BLEs have been found. The source heights of the six BLEs related to negative NBEs are estimated in the range of 16.2–17.8 km. These six events are suggested to occur between the upper positive charge layer and the negative screen charge layer on the top of the normally electrified thunderstorm. The six blue starters, one blue jet, and one type II GJ are inferred to be positive upward discharges from their associated sferics in the extremely low frequency to very low frequency band. Based on the simultaneous radio and optical observations, a NBE is conjectured to be the initiation discharge with rapidly flowing current within the thunderstorm, while a blue jet/starter or a type II GJ is suggested to be the ensuing discharge with slowly varying current propagating upward from the thunderstorm.
19 November 2018 in Journal of Geophysical Research: Atmospheres
In this work, we develop two spectroscopic diagnostic methods to derive the peak reduced electric field in transient luminous events (TLEs) from their optical signals. These methods could be used to analyze the optical signature of TLEs reported by spacecraft such as Atmosphere‐Space Interactions Monitor (European Space Agency) and the future Tool for the Analysis of RAdiations from lightNIngs and Sprites (Centre National d'Études Spatiales). As a first validation of these methods, we apply them to the predicted (synthetic) optical signatures of halos and elves, two types of TLEs, obtained from electrodynamical models. This procedure allows us to compare the inferred value of the peak reduced electric field with the value computed by halo and elve models. Afterward, we apply both methods to the analysis of optical signatures of elves and halos reported by Global LIghtning and sprite MeasurementS (Japan Aerospace Exploration Agency) and Imager of Sprites and Upper Atmospheric Lightning (National Space Organization) spacecraft, respectively. We conclude that the best emission ratios to estimate the maximum reduced electric field in halos and elves are the ratio of the second positive system of N2 to first negative system (FNS) of N , the first positive system of N2 to FNS of N and the Lyman‐Birge‐Hopfield band of N2 to FNS of N . In the case of reduced electric fields below 150 Td, we found that the ratio of the second positive system of N2 to first positive system of N2 can also be used to reasonably estimate the value of the field. Finally, we show that the reported optical signals from elves can be treated following an inversion method in order to estimate some of the characteristics of the parent lightning.
22 August 2019 in Geophysical Research Letters
1 October 2018 in AIP Advances
The DC Langmuir probe is a widely-used instrument for the plasma measurement in the space missions. But to apply DC Langmuir probe to a tiny satellite, such as a cubesat, for ionosphere study is difficult to get accurate electron density (ne) and electron temperature (Te) for two reasons: the contamination on both satellite surface and the electrode to be used, and a lack of conductive surface area of the tiny satellite. Under the charging effect of the satellite with an insufficient area ratio between the surface of the probe and the spacecraft, the contaminations on the surface of both probe and the satellite, acting as equivalent capacitances and resistances, modify both the potentials on the satellite and the probe, and an elevated Te and a suppressed ne are derived incorrectly. In this paper, the effect of the surface contamination on the DC Langmuir probe measurements onboard a tiny satellite is investigated in detail. The effects of the accumulated charge and the impedances on the contamination layers have been identified in the experiments done in a ground chamber with similar plasma conditions in the Earth’s ionosphere, and the characteristic dependences of the probe sweeping frequency and the plasma density are presented. The experiment result suggests that a contamination-free instrument TeNeP, operated at 0.2∼10 MHz probe sweeping frequency and sweeping potentials below 500 mV, is a better solution to obtain accurate Te and ne, onboard a satellite with a surface area ratio below 100.
19 April 2023 in Journal of Geophysical Research: Atmospheres