The aim of this study was to investigate the effect of thermogenic supplementation on the bone tissue of rats subjected to orthodontic movement. A total of 38 male Wistar rats underwent orthodontic movement of the left permanent maxillary first molars for 21 days. The rats were assigned to three groups: Control group: water; Thermogenic 1: C4 Beta Pump thermogenic; or Thermogenic 2: PRE-HD/Pre-workout. Micro-computed tomography (micro-CT) was used to investigate the dynamic changes in the microstructure of alveolar bone during orthodontic tooth movement in rats. Histopathologic analysis was performed by hematoxylin and eosin (H&E) staining, whereas tartrate-resistant acid phosphatase (TRAP) was employed for osteoclast count. Maxillary tissue was collected and evaluated by immunohistochemistry for receptor activator of NF-κB (RANK), receptor activator of NF-κB ligand (RANKL), and osteoprotegerin (OPG). The Thermogenic 2 group exhibited a significantly lower percentage of bone volume fraction (BV/TV) (68.21% ± 17.70%) compared to the control (86.84% + 12.91%) and Thermogenic 1 groups (86.84% + 15.94%) (p < 0.05). The control group had a significantly higher mean orthodontic movement in the mesial direction (0.2143 mm + 0.1513 mm) than the Thermogenic 2 group (0.0420 mm + 0.05215 mm) (p < 0.05). The Thermogenic 2 and Thermogenic 1 groups showed a stronger immunostaining for RANKL when compared to the control group (p < 0.05). The supplementation used in the Thermogenic 2 group (PRE-HD/Pre-workout) induced alveolar bone loss in rats subjected to orthodontic movement, which can be related to the regulation of the RANK/RANKL/OPG signaling pathway. This suggests the influence of thermogenic supplements on bone metabolism seems to depend on their composition.
28 March 2021 in Research, Society and Development
Objective: The objective this review was to identify the current range of shear bond strength values (SBS) that are clinically acceptable based on a synthesis of the studies published in 20 years that evaluated the SBS of brackets bonded to dental enamel with emitter diode light photo activators and whether damage to the enamel has been reported after the test. Methodology: A search strategy was developed for the selection of articles published from 1999 to 2019 in the PubMed/MedLine electronic database. In addition to reading the titles, keywords and summaries of the studies found, the studies were also obtained for the reading of the methodologies and identification of the inclusion and exclusion criteria. Results: The search for scientific articles resulted in 580 studies, but only 14 were selected based on the pre-established criteria. Ten presented methodological quality to be included in this integrative review, and the mean SBS found was 14,05 MPa with a standard deviation of ± 6,52 MPa (range from 7,53 to 20,57 MPa). Conclusion: In conclusion, it was observed that the range of shear bond strength values (5,9 to 7,8 MPa) and taken as a parameter by most authors until now is outdated, since higher values of SBS are feasible without, however, causing dental enamel damage after the debonding of the bracket.
1 January 2021 in Brazilian Archives of Biology and Technology