28 February 2019 in The Analyst
We have improved the sensitivity of a state-of-the-art cantilever-enhanced photo-acoustic trace gas sensor by combining it with an optical power build-up cavity. The build-up cavity enhances the photo-acoustic signal by a factor of ∼100, resulting in an exceptionally good normalised noise equivalent absorption (NNEA) value of 1.75 × 10−12 W cm−1 Hz−1/2. We demonstrate the sensor platform in the 1530 nm wavelength range with a simple distributed feedback diode laser, achieving 75 ppt sensitivity for C2H2 with a 10 s integration time.
1 August 2022 in Physical Chemistry Chemical Physics
We report multipass broadband photoacoustic spectroscopy of trace gases in the mid-infrared. The measurement principle of the sensor relies on supercontinuum-based Fourier transform photoacoustic spectroscopy (FT-PAS), in which a scanning interferometer modulates the intensity of a mid-infrared supercontinuum light source and a cantilever microphone is employed for sensitive photoacoustic detection. With a custom-built external Herriott cell, the supercontinuum beam propagates ten times through a miniature and acoustically non-resonant gas cell. The performance of the FT-PAS system is demonstrated by measuring the fundamental C–H stretch bands of various hydrocarbons. A noise equivalent detection limit of 11 ppb is obtained for methane (40 s averaging time, 15 μW cm−1 incident power spectral density, 4 cm−1 resolution), which is an improvement by a factor of 12 compared to the best previous FT-PAS systems. High linearity and good stability of the sensor provide reliable identification of individual species from a gas mixture with strong spectral overlap, laying the foundation for sensitive and selective multi-species detection in small sample volumes.
10 September 2020 in arXiv
An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytterbium, the ion's complex structure makes this shift difficult to calculate theoretically. We present a measurement of the differential polarizabilities of two ultra-narrow optical clock transitions present in $^{171}\mathrm{Yb}^+$, performed by exposing the ion to an oscillating electric field at a wavelength in the region of room temperature BBR spectra. By measuring the frequency shift to the transitions caused by a laser at $\lambda=7.17 \mu m$, we obtain values for scalar and tensor differential polarizabilities with uncertainties at the percent level for both the electric quadrupole and octupole transitions at 436nm and 467nm respectively. These values agree with previously reported experimental measurements and, in the case of the electric quadrupole transition, allow a 5-fold improvement in the determination of the room-temperature BBR shift. However, we note significant concerns over the validity of the uncertainty charactarization presented and draw the reader's attention to the Note on applicability section for a discussion.