Tommi Mikkonen

Tommi Mikkonen

Auto-generated profile, based on publicly available information

Tommi Mikkonen

Department of Chemistry, University of Helsinki, Helsinki, FI-00560, Finland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2018 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
ISIbrahim Sadiek
Ibrahim Sadiek
TMTommi Mikkonen
Tommi Mikkonen
MVMarkku Vainio
Markku Vainio
JTJuha Toivonen
Juha Toivonen
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
We report the first photoacoustic detection scheme using an optical frequency comb—optical frequency comb photoacoustic spectroscopy (OFC-PAS). OFC-PAS combines the broad spectral coverage and the high resolution of OFCs with the small sample volume of cantilever-enhanced PA detection. In OFC-PAS, a Fourier transform spectrometer (FTS) is used to modulate the intensity of the exciting comb source at a frequency determined by its scanning speed. One of the FTS outputs is directed to the PA cell and the other is measured simultaneously with a photodiode and used to normalize the PA signal. The cantilever-enhanced PA detector operates in a non-resonant mode, enabling detection of a broadband frequency response. The broadband and the high-resolution capabilities of OFC-PAS are demonstrated by measuring the rovibrational spectra of the fundamental C–H stretch band of CH4, with no instrumental line shape distortions, at total pressures of 1000 mbar, 650 mbar, and 400 mbar. In this first demonstration, a spectral resolution two orders of magnitude better than previously reported with broadband PAS is obtained, limited by the pressure broadening. A limit of detection of 0.8 ppm of methane in N2 is accomplished in a single interferogram measurement (200 s measurement time, 1000 MHz spectral resolution, 1000 mbar total pressure) for an exciting power spectral density of 42 μW/cm−1. A normalized noise equivalent absorption of 8 × 10−10 W cm−1 Hz−1/2 is obtained, which is only a factor of three higher than the best reported with PAS based on continuous wave lasers. A wide dynamic range of up to four orders of magnitude and a very good linearity (limited by the Beer–Lambert law) over two orders of magnitude are realized. OFC-PAS extends the capability of optical sensors for multispecies trace gas analysis in small sample volumes with high resolution and selectivity.

12 October 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TMTommi Mikkonen
Tommi Mikkonen
CACaroline Amiot
Caroline Amiot
AAAntti Aalto
Antti Aalto
KPKim Patokoski
Kim Patokoski
GGGoëry Genty
Goëry Genty
JTJuha Toivonen
Juha Toivonen
We demonstrate cantilever-enhanced photoacoustic spectroscopy in the mid-infrared using a supercontinuum source. The approach is broadband and allows for higher photoacoustic signal intensity and an enhanced signal-to-noise ratio as compared to systems employing conventional black body radiation sources. Using this technique, we perform spectroscopic measurements of the full ro-vibrational band structure of water vapor at 1900 nm and methane at 3300 nm with relative signal enhancement factors of 70 and 19, respectively, when compared to measurements that use the black body radiation source. Our results offer a novel perspective for photoacoustic detection opening the door to sensitive broadband analyzers in the mid-infrared spectral region.

1 August 2022 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
TMTommi Mikkonen
Tommi Mikkonen
THTuomas Hieta
Tuomas Hieta
GGGoëry Genty
Goëry Genty
JTJuha Toivonen
Juha Toivonen
We report multipass broadband photoacoustic spectroscopy of trace gases in the mid-infrared. The measurement principle of the sensor relies on supercontinuum-based Fourier transform photoacoustic spectroscopy (FT-PAS), in which a scanning interferometer modulates the intensity of a mid-infrared supercontinuum light source and a cantilever microphone is employed for sensitive photoacoustic detection. With a custom-built external Herriott cell, the supercontinuum beam propagates ten times through a miniature and acoustically non-resonant gas cell. The performance of the FT-PAS system is demonstrated by measuring the fundamental C–H stretch bands of various hydrocarbons. A noise equivalent detection limit of 11 ppb is obtained for methane (40 s averaging time, 15 μW cm−1 incident power spectral density, 4 cm−1 resolution), which is an improvement by a factor of 12 compared to the best previous FT-PAS systems. High linearity and good stability of the sensor provide reliable identification of individual species from a gas mixture with strong spectral overlap, laying the foundation for sensitive and selective multi-species detection in small sample volumes.

28 February 2025 in Aerosol Research
Verified
Journal Article
Open access
PDF file
JKJuho Karhu
Juho Karhu
TMTommi Mikkonen
Tommi Mikkonen
JKJoel Kuula
Joel Kuula
AVAki Virkkula
Aki Virkkula
EIErkki Ikonen
Erkki Ikonen
THTuomas Hieta
Tuomas Hieta
We demonstrate a measurement of aerosol absorption at three wavelengths for particles below 1 µm in diameter using a highly sensitive photoacoustic spectrometer. The acoustic signal is detected with a cantilever microphone, which allows for sensitive detection without the need to apply acoustic resonance to enhance the signal. The lack of resonator makes the instrument compact and well suited for field measurements. A field instrument employing the method was developed and deployed for black carbon monitoring at an air quality measurement station. The method shows excellent sensitivity for in situ aerosol absorption measurement, with detection limits of 0.016, 0.025 and 0.041 Mm−1, for simultaneous measurements at the wavelengths of 445, 520 and 638 nm, respectively, using a 1 h averaging time. The black carbon concentration measured with the new instrument is compared against filter-based photometers operating at the site, showing high correlation.

13 January 2025 in Aerosol Research
Verified
Journal Article
Open access
PDF file
JKJoel Kuula
Joel Kuula
JKJuho Karhu
Juho Karhu
TMTommi Mikkonen
Tommi Mikkonen
PGPatrick Grahn
Patrick Grahn
AVAki Virkkula
Aki Virkkula
MVMarkku Vainio
Markku Vainio
Particle light absorption enhancement, also known as the lensing effect, is a complex phenomenon where particles undergo optical transformation as they age. This process is influenced by several factors, including particle size. To investigate the lensing effect, this study introduces and validates a novel method for size-resolved light absorption measurements using nigrosin particles as a model system. The method combines a three-wavelength cantilever-enhanced photoacoustic spectrometer (CEPAS) with a differential mobility analyser (DMA) to achieve particle-size-resolved measurements. Nigrosin, a well-characterised, spherically shaped, and water-soluble material, was selected to demonstrate the feasibility and precision of the approach. The system showed strong agreement (R2>0.94) with Mie-modelled absorption, confirming its reliability. While the broader motivation for this work lies in advancing techniques for studying ageing, coating, and absorption enhancement in black carbon and other atmospheric aerosols, the present study serves as a foundational step by validating the methodology in a controlled and simplified context. Future studies will expand the application of this method to complex systems, including coated and aggregated black carbon particles, to explore phenomena such as absorption enhancement.

25 March 2022 in Optics Letters
Verified
Journal Article
Open access
TMTommi Mikkonen
Tommi Mikkonen
ZEZahra Eslami
Zahra Eslami
GGGoëry Genty
Goëry Genty
JTJuha Toivonen
Juha Toivonen
We investigate the noise transfer mechanism from the light source intensity fluctuations to the acoustic signal in Fourier transform photoacoustic spectroscopy (FT-PAS). This noise coupling is expected to be reduced in FT-PAS compared with conventional Fourier transform spectroscopy, as only the specific spectral components that are absorbed by the probed sample contribute to the noise level. We employ an incoherent supercontinuum (SC) light source in our experiments and observe a linear relation between the sample gas concentration and the detected noise level, which significantly reduces the influence of the SC noise on the detection limit. Based on our experimental results, we derive a model for the noise level, which establishes the foundation for practical sensitive implementation of FT-PAS.