Jon Thor Asmussen

Jon Thor Asmussen

Auto-generated profile, based on publicly available information

Jon Thor Asmussen

Department of Radiology, Odense University Hospital, Odense, Denmark

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Radiology
Verified
Journal Article
Open access
CMChristina Messiou
Christina Messiou
JHJens Hillengass
Jens Hillengass
Stefan DelormeStefan Delorme
Stefan Delorme
FLFrédéric E. Lecouvet
Frédéric E. Lecouvet
LMLia Angela Moulopoulos
Lia Angela Moulopoulos
APAnwar Padhani
Anwar Padhani
Acknowledging the increasingly important role of whole-body MRI for directing patient care in myeloma, a multidisciplinary, international, and expert panel of radiologists, medical physicists, and hematologists with specific expertise in whole-body MRI in myeloma convened to discuss the technical performance standards, merits, and limitations of currently available imaging methods. Following guidance from the International Myeloma Working Group and the National Institute for Clinical Excellence in the United Kingdom, the Myeloma Response Assessment and Diagnosis System (or MY-RADS) imaging recommendations are designed to promote standardization and diminish variations in the acquisition, interpretation, and reporting of whole-body MRI in myeloma and allow response assessment. This consensus proposes a core clinical protocol for whole-body MRI and an extended protocol for advanced assessments.

1 February 2013 in Gynecologic Oncology
Verified
Journal Article
Closed access
SASofie Leisby Antonsen
Sofie Leisby Antonsen
LJLisa Neerup Jensen
Lisa Neerup Jensen
ALAnnika Loft
Annika Loft
ABAnne Kiil Berthelsen
Anne Kiil Berthelsen
JCJunia Costa
Junia Costa
CHClaus Kim Høgdall
Claus Kim Høgdall

1 June 2017 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
MRMax Rohde
Max Rohde
ANAnne L. Nielsen
Anne L. Nielsen
JJJørgen Johansen
Jørgen Johansen
JSJens Ahm Sørensen
Jens Ahm Sørensen
NNNina Nguyen
Nina Nguyen
CGChristian Godballe
Christian Godballe
The purpose of this study was to determine the detection rate of distant metastasis and synchronous cancer, comparing clinically used imaging strategies based on chest x-ray + head and neck MRI (CXR/MRI) and chest CT + head and neck MRI (CHCT/MRI) with 18F-FDG PET/CT upfront in the diagnostic workup of patients with oral, pharyngeal, or laryngeal cancer. Methods: This was a prospective cohort study based on paired data. Consecutive patients with histologically verified primary head and squamous cell carcinoma at Odense University Hospital from September 2013 to March 2016 were considered for the study. Included patients underwent CXR/MRI and CHCT/MRI as well as PET/CT on the same day and before biopsy. Scans were read masked by separate teams of experienced nuclear physicians or radiologists. The true detection rate of distant metastasis and synchronous cancer was assessed for CXR/MRI, CHCT/MRI, and PET/CT. Results: A total of 307 patients were included. CXR/MRI correctly detected 3 (1%) patients with distant metastasis, CHCT/MRI detected 11 (4%) patients, and PET/CT detected 18 (6%) patients. The absolute differences of 5% and 2%, respectively, were statistically significant in favor of PET/CT. Also, PET/CT correctly detected 25 (8%) synchronous cancers, which was significantly more than CXR/MRI (3 patients, 1%) and CHCT/MRI (6 patients, 2%). The true detection rate of distant metastasis or synchronous cancer with PET/CT was 13% (40 patients), which was significantly higher than 2% (6 patients) for CXR/MRI and 6% (17 patients) for CHCT/MRI. Conclusion: A clinical imaging strategy based on PET/CT demonstrated a significantly higher detection rate of distant metastasis or synchronous cancer than strategies in current clinical imaging guidelines, of which European ones primarily recommend CXR/MRI, whereas U.S. guidelines preferably point to CHCT/MRI in patients with head and neck squamous cell carcinoma.

30 July 2020 in Cancers
Verified
Journal Article
Open access
PDF file
SRStine Rasch
Stine Rasch
TLThomas Lund
Thomas Lund
JAJon Thor Asmussen
Jon Thor Asmussen
ANAnne Lerberg Nielsen
Anne Lerberg Nielsen
RLRikke Faebo Larsen
Rikke Faebo Larsen
NANiels Abildgaard
Niels Abildgaard
The lytic bone disease is a hallmark of multiple myeloma, being present in about 80% of patients with newly diagnosed MM, and in more during the disease course. The myeloma associated bone disease (MBD) severely affects the morbidity and quality of life of the patients. MBD defines treatment demanding MM. In recent years, knowledge of the underlying pathophysiology has increased, and novel imaging technologies, medical and non-pharmaceutical treatments have improved. In this review, we highlight the major achievements in understanding, diagnosing and treating MBD. For diagnosing MBD, low-dose whole-body CT is now recommended over conventional skeletal survey, but also more advanced functional imaging modalities, such as diffusion-weighted MRI and PET/CT are increasingly important in the assessment and monitoring of MBD. Bisphosphonates have, for many years, played a key role in management of MBD, but denosumab is now an alternative to bisphosphonates, especially in patients with renal impairment. Radiotherapy is used for uncontrolled pain, for impeding fractures and in treatment of impeding or symptomatic spinal cord compression. Cement augmentation has been shown to reduce pain from vertebral compression fractures. Cautious exercise programs are safe and feasible and may have the potential to improve the status of patients with MM.

1 May 2013 in Gynecologic Oncology
Verified
Journal Article
Closed access
SASofie Leisby Antonsen
Sofie Leisby Antonsen
ALAnnika Loft
Annika Loft
RFRune Fisker
Rune Fisker
ANAnne Lerberg Nielsen
Anne Lerberg Nielsen
EAErik Søgaard Andersen
Erik Søgaard Andersen
CHClaus Kim Høgdall
Claus Kim Høgdall

13 February 2017 in Acta Oncologica
Verified
Journal Article
Open access
CHChristian Rønn Hansen
Christian Rønn Hansen
RCRasmus Lübeck Christiansen
Rasmus Lübeck Christiansen
ELEbbe Laugaard Lorenzen
Ebbe Laugaard Lorenzen
ABAnders Smedegaard Bertelsen
Anders Smedegaard Bertelsen
JAJon Thor Asmussen
Jon Thor Asmussen
CBCarsten Brink
Carsten Brink
Background: Delineation accuracy of the gross tumor volume (GTV) in radiotherapy planning for head and neck (H&N) cancer is affected by computed tomography (CT) artifacts from metal implants which obscure identification of tumor as well as organs at risk (OAR). This study investigates the impact of metal artifact reduction (MAR) in H&N patients in terms of delineation consistency and dose calculation precision in radiation treatment planning. Material and methods: Tumor and OAR delineations were evaluated in planning CT scans of eleven oropharynx patients with streaking artifacts in the tumor region preceding curative radiotherapy (RT). The GTV-tumor (GTV-T), GTV-node and parotid glands were contoured by four independent observers on standard CT images and MAR images. Dose calculation was evaluated on thirty H&N patients with dental implants near the treated volume. For each patient, the dose derived from the clinical treatment plan using the standard image set was compared with the recalculated dose on the MAR image dataset. Results: Reduction of metal artifacts resulted in larger volumes of all delineated structures compared to standard reconstruction. The GTV-T and the parotids were on average 22% (p < 0.06) and 7% larger (p = 0.005), respectively, in the MAR image plan compared to the standard image plan. Dice index showed reduced inter-observer variations after reduction of metal artifacts for all structures. The average surface distance between contours of different observers improved using the MAR images for GTV and parotids (p = 0.04 and p = 0.01). The median volume receiving a dose difference larger than ±3% was 2.3 cm3 (range 0–32 cm3). Conclusions: Delineation of structures in the head and neck were affected by metal artifacts and volumes were generally larger and more consistent after reduction of metal artifacts, however, only small changes were observed in the dose calculations.