Insulation and mechanical defects are the main reasons of the power equipment fault, the former could generate partial discharge (PD) which can be detected by acoustic emission (AE) sensor, the other one can be evaluated by vibration and temperature variation. However, the two defects are detected and analyzed independently in traditional detection, the importance of multi-signal interaction and fusion analysis is ignored. To realize multi-signal synchronous detection and associated analysis, and improve the accuracy and efficiency of state evaluation of power equipment, a novel integrated electronics piezoelectric (IEPE) AE-vibration-temperature combined intelligent sensor is proposed and developed in this paper. Reasonable structure design and components customization enable the sensor to acquire signals simultaneously. Meanwhile, integrated transducer electronic data sheet (TEDS) and data processing circuit intelligentize the combined sensor. The primary detection parameters of the sensor are acquired in the calibration experiments. In PD, vibration and temperature joint experiment, it is verified that the combined sensor is more sensitive and multifunctional. Besides, a new fusion analysis diagram, vibration-phase resolved partial discharge (V-PRPD), is proposed to characterise the correlation between PD and vibration.
1 March 2024 in IEEE Transactions on Instrumentation and Measurement
The gas state of the insulating gas significantly impacts the development and extent of the partial discharge (PD) in gas insulated switchgear (GIS). Correlating these two factors allows for a more comprehensive diagnosis of insulation defects. At present, the ultra-high frequency (UHF) method has been widely used for PD detection in GIS. However, measurements of the insulating gas’s state in the field are primarily conducted offline or at gas valves, providing ineffective data for reference. To address this challenge, this paper introduces a novel composite sensor capable of simultaneous UHF and gas state measurements. Building upon the disc-type UHF sensor structure, the composite sensor integrates a gas state sensing unit with the microelectromechanical systems (MEMS) sensor as the core. A robust shielding shell is designed through finite element simulation to ensure the safety of the sensor, with the maximum induced voltage and electric field strength on the sensing unit measuring 0.28V and 414V/m, respectively. The average UHF measurement sensitivity of the composite sensor reaches 13.3mm. In addition, the composite sensor exhibits low errors (±0.2°C, ±3kPa and ±10μL/L), high consistency and repeatability in temperature, pressure and moisture measurement. Finally, the composite sensor has demonstrated its capability to simultaneously and safely detect PD signals and the gas state within GIS.
7 April 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
The attachment of metal particles on the surface of insulators is a significant source of surface discharges and operational failures in gas insulated switchgear (GIS). This study systematically investigated the characteristics of surface partial discharge (PD) under both AC voltage and AC superimposed switching impulse voltage, verifying the feasibility of monitoring PDs during switching operations to detect surface defects within GIS. The development of surface PD under AC voltage can be categorized into three stages with relatively low discharge amplitudes observed in the initial two stages. Surface PDs can only be effectively measured using ultra-high frequency (UHF) and optical devices once PD progression becomes pronounced. When switching impulses with an amplitude of 2.2 times AC voltage were superimposed at various AC phases, sustained and high-amplitude PDs were induced following the impulses, even when the AC voltage remains below the PD inception voltage. Space and surface charge introduced by PDs under switching impulse distort the electric field, thereby triggering subsequent discharges. The amplitude and duration of PDs excited by superimposed impulse voltage are adequate for UHF detection. This finding suggests the potential for timely detection of surface defects in GIS by monitoring PD conditions during switchgear operation.
Medium-voltage (MV) switchgear and gas insulated switchgear (GIS) are essential components of power-grid systems. Their safe operation is crucial for the electricity consumption of users. However, insulation faults often occur during the operation of MV switchgear and GIS because of pollution, humidity, heat, mechanical shock, and other factors. Partial discharge (PD) measurements are the most effective indicator to prevent insulation failure. Transient earth voltage (TEV) and ultrasonic methods are the most popular PD measurement methods for switchgear. Currently, these two methods are used widely and independently. In this study, a novel TEV-ultrasonic integrated sensor is proposed based on the independent structure of the TEV and the ultrasonic sensor. The performance parameters of the proposed sensor were tested on test platforms. PD measurement experiments were conducted in a 10 kV switchgear and 220 kV GIS to analyze the performance of the integrated sensor. The results show that the sensor can simultaneously measure the TEV and ultrasonic signals in the same location. The integrated sensor can realize effective and sensitive detection, precise location, and accurate diagnosis of PD in the MV switchgear and GIS.
7 April 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Surface discharge along insulators is one of the primary causes of gas insulated switchgear (GIS) failures, with temperature variations caused by load fluctuations further affecting insulation performance. This study developed a GIS temperature control system based on oil circulation to simulate actual thermal conditions and investigated the inception and development characteristics of surface partial discharge (PD) under varying temperatures. Metallic defects were introduced on the insulator surface to initiate discharges, and the results showed that increasing temperature lowers the PD inception voltage, significantly increases the discharge repetition rate, and accelerates the transition between discharge modes. Elevated temperature also causes the amplitude-frequency distribution curves to shift toward higher amplitudes at the same voltage. On the one hand, the non-uniform temperature rises within GIS result in an uneven distribution of gas density, thereby weakening the insulation strength. On the other hand, elevated temperatures enhance the mechanisms of initial electron generation, charge decay, and secondary electron emission, further promoting the development of discharge processes. This study highlights the effect of temperature on GIS surface PD inception and development characteristics.