3 May 2022 in IEEE Transactions on Power Delivery
The faults of electrical equipment are mainly generated by electrical and mechanical defects, which are usually detected by external ultrasonic and vibration sensors respectively. To improve the accuracy and efficiency of the diagnosis, a novel ultrasound-vibration composite sensor(UVCS) which can detect ultrasound and vibration acceleration signals synchronously at the same place, is proposed and developed scientifically in this paper. The working principle of UVCS is based on the combination of the mass and the backing as well as the steel base and matching layer, and the structure is improved reasonably. Furthermore, the ultrasound and vibration signals can be separated by filtering. In addition, the test results on a 110kV GIS show the high precision and reliability of UVCS and illustrate the superiority in practical application.
1 July 2020 in IET Generation, Transmission & Distribution
In this study, to improve the sensitivity and accuracy of the detection of surface partial discharge (PD) in gas insulation switchgears (GISs), a combination of ultra‐high frequency (UHF) and optical methods is proposed based on an integrated sensor. The PD triggered by a fixed metal needle defect attached to the spacer is detected from PD inception to flashover in a real GIS. The characteristics of UHF and optical signals under different applied voltages are compared and analysed in terms of PD waveform, Phase Resolved Partial Discharge (PRPD) pattern, PD count and amplitude. The results show that the surface discharge process can be precisely divided into three stages according to the combined characteristics of the UHF and optical signals. The comparison of the two detection methods shows that the optical method can detect the weak avalanche PD under low voltage while UHF cannot, so it can detect more PDs than UHF method in an AC cycle. In addition, with the deterioration of solid insulation material, the amplitude of the optical signal increases significantly while the amplitude of the UHF signal only increases slightly.
1 March 2024 in IEEE Transactions on Instrumentation and Measurement
The gas state of the insulating gas significantly impacts the development and extent of the partial discharge (PD) in gas insulated switchgear (GIS). Correlating these two factors allows for a more comprehensive diagnosis of insulation defects. At present, the ultra-high frequency (UHF) method has been widely used for PD detection in GIS. However, measurements of the insulating gas’s state in the field are primarily conducted offline or at gas valves, providing ineffective data for reference. To address this challenge, this paper introduces a novel composite sensor capable of simultaneous UHF and gas state measurements. Building upon the disc-type UHF sensor structure, the composite sensor integrates a gas state sensing unit with the microelectromechanical systems (MEMS) sensor as the core. A robust shielding shell is designed through finite element simulation to ensure the safety of the sensor, with the maximum induced voltage and electric field strength on the sensing unit measuring 0.28V and 414V/m, respectively. The average UHF measurement sensitivity of the composite sensor reaches 13.3mm. In addition, the composite sensor exhibits low errors (±0.2°C, ±3kPa and ±10μL/L), high consistency and repeatability in temperature, pressure and moisture measurement. Finally, the composite sensor has demonstrated its capability to simultaneously and safely detect PD signals and the gas state within GIS.
8 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Oscillating lightning impulse (OLI) voltage is recommended for on-site testing due to its high generation efficiency. In this paper, partial discharge (PD) characteristics under field impulse voltage waveforms are investigated. The experiment is carried out on a scaled transformer model with a protrusion defect inside as the PD source. Both oscillating and standard lightning impulse (SLI) voltages are acquired as test waveforms. Main discharges and reverse discharges are detected simultaneously under both OLI and SLI voltage. The increasing applied voltage amplitude advances the main discharge and enlarges its amplitude, and it also prolongs the duration of the reverse discharge and increases the number. The amplitude of main discharge is related to the PD voltage, while that of reverse discharge depends on the dynamic variation of the impulse voltage. Since OLI voltage contains multiple rising edges during the oscillation period, more PDs are excited. Disruptive effect (DE) model is extended for PD analysis to show the oscillation effect on PD distribution. The OLI test with PD measurement performed on a 220 kV transformer proves that PD detection during impulse voltage withstand test reflects more detailed information that can be used for early diagnosis of power transformers.
5 August 2020 in IEEE Transactions on Dielectrics and Electrical Insulation
In this paper the behavior of partial discharges (PDs) on epoxy insulation under AC and impulse superimposed voltages are experimentally investigated in SF 6 gas. The lightning impulse (LI) and the switching impulse (SI) voltages with different polarity are superimposed on different phases of the AC voltage. PDs are measured by three sensors, a 50 Ω measurement impedance, an ultra-high frequency sensor and a photomultiplier tube. The max PD amplitude, PD pulse number and PD duration under AC voltage after an impulse voltage are summarized and analyzed. The effect of the impulse superposition phase, the impulse type and the impulse polarity on the characteristics of AC PDs are discussed. Results show that after a positive impulse voltage was applied on the positive semi-wave of AC voltage (0 to 180°), PDs in the negative half cycle of the AC voltage can be remarkably excited. A negative impulse voltage was applied on the negative semi-wave (180 to 360°), AC PDs can be initiated in the positive half cycle of AC voltage. PDs excited by a LI voltage is severe than excited by a SI. PDs excited by a positive impulse is intense than excited by a negative impulse.
25 March 2020 in IEEE Transactions on Dielectrics and Electrical Insulation
With the development of high-voltage direct-current (HVDC) transmission, DC gas insulated lines (GIL) with SF 6 /N 2 gas mixtures as insulating medium have been successfully adopted. Space is typically the weak link of equipment insulation where surface discharge is one of the common discharge forms in power equipment. Therefore, research on the surface discharge characteristics of SF 6 /N 2 under DC voltage can contribute to insulation design of SF 6 /N 2 insulated DC GIS, GIL and other power equipment. In this paper, a DC high-voltage experimental system is established to study partial discharge (PD) along insulation surfaces. The characteristics at the initial discharge and the discharge development stages are analyzed in detail. Additionally, the synergistic effect of mixed gas is investigated based on the discharge characteristics and the synergistic effect coefficient is introduced. The experimental results show that the synergistic effect of mixed gas partial discharge inception voltage (PDIV) under high pressure is more obvious compared to low pressure and the discharge quantities of mixed gas is smaller than that of pure SF 6 at the discharge development stage. This study on the multiple influencing factors of synergistic effect is expected to provide important insight for exploring the SF 6 /N 2 discharge mechanism and helps decreasing the usage SF 6 .