Karolina Stachnik

Karolina Stachnik

Auto-generated profile, based on publicly available information

Karolina Stachnik

University of Hamburg

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2017 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
SBSasa Bajt
Sasa Bajt
MPMauro Prasciolu
Mauro Prasciolu
HFHolger Fleckenstein
Holger Fleckenstein
MDMartin Domaracký
Martin Domaracký
HCHenry Chapman
Henry Chapman
CHChristian E Hamm
Christian E Hamm
Multilayer Laue lenses are volume diffraction elements for the efficient focusing of X-rays. With a new manufacturing technique that we introduced, it is possible to fabricate lenses of sufficiently high numerical aperture (NA) to achieve focal spot sizes below 10 nm. The alternating layers of the materials that form the lens must span a broad range of thicknesses on the nanometer scale to achieve the necessary range of X-ray deflection angles required to achieve a high NA. This poses a challenge to both the accuracy of the deposition process and the control of the materials properties, which often vary with layer thickness. We introduced a new pair of materials—tungsten carbide and silicon carbide—to prepare layered structures with smooth and sharp interfaces and with no material phase transitions that hampered the manufacture of previous lenses. Using a pair of multilayer Laue lenses (MLLs) fabricated from this system, we achieved a two-dimensional focus of 8.4 × 6.8 nm2 at a photon energy of 16.3 keV with high diffraction efficiency and demonstrated scanning-based imaging of samples with a resolution well below 10 nm. The high NA also allowed projection holographic imaging with strong phase contrast over a large range of magnifications. An error analysis indicates the possibility of achieving 1 nm focusing.

14 March 2016 in The European Physical Journal Plus
Verified
Journal Article
Closed access
PDF file
ABAnja Burkhardt
Anja Burkhardt
TPTim Pakendorf
Tim Pakendorf
BRBernd Reime
Bernd Reime
JMJan Meyer
Jan Meyer
PFPontus Fischer
Pontus Fischer
AMAlke Meents
Alke Meents

6 July 2015 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
KSK. Stachnik
K. Stachnik
IMI. Mohacsi
I. Mohacsi
IVI. Vartiainen
I. Vartiainen
NSN. Stuebe
N. Stuebe
JMJ. Meyer
J. Meyer
AMA. Meents
A. Meents
X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly coherent illumination provides images with better spatial resolution and fewer artefacts than the approach with partial coherence.

8 July 2020 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
AMAndrew J. Morgan
Andrew J. Morgan
KMKevin T. Murray
Kevin T. Murray
MPMauro Prasciolu
Mauro Prasciolu
HFHolger Fleckenstein
Holger Fleckenstein
OYOleksandr M. Yefanov
Oleksandr M. Yefanov
SBSasa Bajt
Sasa Bajt
The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

4 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KSKarolina Stachnik
Karolina Stachnik
MWMartin Warmer
Martin Warmer
IMIstvan Mohacsi
Istvan Mohacsi
VHVincent Hennicke
Vincent Hennicke
PFPontus Fischer
Pontus Fischer
AMAlke Meents
Alke Meents
Studies of biological systems typically require the application of several complementary methods able to yield statistically-relevant results at a unique level of sensitivity. Combined X-ray fluorescence and ptychography offer excellent elemental and structural imaging contrasts at the nanoscale. They enable a robust correlation of elemental distributions with respect to the cellular morphology. Here we extend the applicability of the two modalities to higher X-ray excitation energies, permitting iron mapping. Using a long-range scanning setup, we applied the method to two vital biomedical cases. We quantified the iron distributions in a population of macrophages treated with Mycobacterium-tuberculosis-targeting iron-oxide nanocontainers. Our work allowed to visualize the internalization of the nanocontainer agglomerates in the cytosol. From the iron areal mass maps, we obtained a distribution of antibiotic load per agglomerate and an average areal concentration of nanocontainers in the agglomerates. In the second application we mapped the calcium content in a human bone matrix in close proximity to osteocyte lacunae (perilacunar matrix). A concurrently acquired ptychographic image was used to remove the mass-thickness effect from the raw calcium map. The resulting ptychography-enhanced calcium distribution allowed then to observe a locally lower degree of mineralization of the perilacunar matrix.

5 February 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
IVIsmo Vartiainen
Ismo Vartiainen
IMIstvan Mohacsi
Istvan Mohacsi
KSKarolina Stachnik
Karolina Stachnik
MGManuel Guizar-Sicairos
Manuel Guizar-Sicairos
CDChristian David
Christian David
AMAlke Meents
Alke Meents
We present an imaging technique combining Zernike phase-contrast imaging and ptychography. The contrast formation is explained by following the theory of Zernike phase-contrast imaging. The method is demonstrated with x-rays at a photon energy of 6.2 keV, showing how ptychographic reconstruction of a phase sample leads to a Zernike phase-contrast image appearing in the amplitude reconstruction. In addition, the results presented in this Letter indicate an improvement of the resolution of the reconstructed object in the case of Zernike ptychography compared with the conventional one.