Muhammad Imam Sudrajat

Muhammad Imam Sudrajat

Auto-generated profile, based on publicly available information

Muhammad Imam Sudrajat

National Research and Innovation Agency

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
KKKhusnul Khotimah
Khusnul Khotimah
YYYoppy Yoppy
Yoppy Yoppy
MSMuhammad Imam Sudrajat
Muhammad Imam Sudrajat
VPVera Permatasari
Vera Permatasari
ETElvina Trivida
Elvina Trivida
TWTyas Ari Wahyu Wijarnoko
Tyas Ari Wahyu Wijarnoko
This paper investigates the effect of two different heating power control systems of infant incubators on their conducted emissions. Two infant incubators which respectively employ zero-crossing control mode and phase angle control mode are observed. The research was conducted by measuring conducted electromagnetic interference (EMI) from each infant incubator's power input. Measurements are conducted both during full power condition, while the incubator's compartment temperature is far away from the temperature setpoint, and during power chopping condition, while the compartment temperature reaches the steady-state set point. Method and limit of the measurement refer to CISPR 11. It is found that conducted emission higher than the standard CISPR 11 limit occurs during power chopping on phase angle control mode. This results from the sharp rise time of voltage delivered to the heater, around 220 ns for each chopping cycle.

1 April 2025 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
ETElvina Trivida
Elvina Trivida
MSMuhammad Imam Sudrajat
Muhammad Imam Sudrajat
WAWuwus Ardiatna
Wuwus Ardiatna
HPHaryo Dwi Prananto
Haryo Dwi Prananto
HNHutomo Wahyu Nugroho
Hutomo Wahyu Nugroho
RAR Harry Arjadi
R Harry Arjadi
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.