The measurement and analysis of electromagnetic interference (EMI) from light rapid transit (LRT) axle counters against magnetic field interference in Indonesia has been carried out. The low-cost magnetic sensors were developed according to the British Standard (BS) EN 50592:2016. The measurement setup and magnetic field limit were based on the British Standard EN 50592:2016 and ERA/ERTMS/033281 standard. Two frequency range of the measurements, lower and higher frequencies with two different train running mode, acceleration mode and deceleration mode were applied in this research. The results in lower frequency range (10 to 100 kHz) were very close to the limit value in both acceleration and deceleration mode, especially at the 30 to 50 kHz for the y and z directions. Although there may possibly magnetic interference at low frequencies, most of the magnetic field emissions were still in acceptable range.
Emergency braking detection plays a vital role in enhancing road safety by identifying potentially hazardous driving behaviors. While existing methods rely heavily on artificial intelligence and computationally intensive algorithms, this paper proposes a lightweight, real-time algorithm for distinguishing emergency braking from non-emergency events using accelerometer and gyroscope signals. The proposed approach applies magnitude calculations and a moving average filters algorithm to preprocess inertial data collected from a six-axis IMU sensor. By analyzing peak values of acceleration and angular velocity, the algorithm successfully separates emergency braking from other events such as regular braking, passing over speed bumps, or traversing damaged roads. The results demonstrate that emergency braking exhibits a unique short-pulse pattern in acceleration and low angular velocity, distinguishing it from other high-oscillation disturbances. Furthermore, varying the window length of the moving average impacts classification accuracy and computational cost. The proposed method avoids the complexity of neural networks while retaining high detection accuracy, making it suitable for embedded and real-time vehicular systems, such as early warning applications for fleet management.
1 February 2024 in International Journal of Electrical and Computer Engineering (IJECE)
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
1 April 2025 in Bulletin of Electrical Engineering and Informatics
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.