1 July 2010 in Journal of Structural Engineering
Hybrid coupled walls (HCWs) are comprised of two or more reinforced concrete wall piers connected with steel coupling beams distributed over the height of the structure. Extensive research over the past several decades suggests that such systems are particularly well suited for use in regions of moderate to high seismic risk. This paper reviews the state of the art in seismic modeling, analysis, and design of HCW systems. Design methodologies are presented in both prescriptive and performance-based design formats and a discussion of alterative types of hybrid wall systems is provided.
1 February 2018 in Journal of Structural Engineering
Steel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 20-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.
1 September 2012 in Journal of Bridge Engineering
The introduction of steel reinforcing bars having yield strengths exceeding 517 MPa (75 ksi) and often approaching 827 MPa (120 ksi) may allow for significant economies to be realized, particularly when used in conjunction with high-strength concrete. One implication of the adoption of higher-strength reinforcing steel is that reinforcing bar stresses (and therefore strains and consequently crack widths) at service load levels are expected to be greater than when conventional bars [having a yield of 414 MPa (60 ksi)] are used. A study of flexural crack widths of beams reinforced with high-strength ASTM A1035 reinforcing steel is presented. Discussion focuses on the behavior at loads corresponding to longitudinal reinforcing bar stresses of 248, 414, and 496 MPa (36, 60, and 72 ksi), representing service load levels (i.e., 0.6fy) for steel having fy = 414,690, and 827 MPa (60, 100, and 120 ksi), respectively. Average measured crack widths obtained from a series of flexural beams having reinforcing ...
1 April 2001 in Progress in Structural Engineering and Materials
1 April 2018 in Engineering Structures
MRMuhammad Mostafijur Rahman
Muhammad Mostafijur Rahman