Bahram M. Shahrooz

Bahram M. Shahrooz

Auto-generated profile, based on publicly available information

Bahram M. Shahrooz

Professor, Dept. of CAECM, Univ. of Cincinnati, 765 Baldwin Hall, Cincinnati, OH 45221. ORCID:

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2010 in Journal of Structural Engineering
Verified
Journal Article
Closed access
SESherif El-Tawil
Sherif El-Tawil
KHKent A. Harries
Kent A. Harries
PFPatrick J. Fortney
Patrick J. Fortney
BSBahram M. Shahrooz
Bahram M. Shahrooz
YKYahya Kurama
Yahya Kurama
Hybrid coupled walls (HCWs) are comprised of two or more reinforced concrete wall piers connected with steel coupling beams distributed over the height of the structure. Extensive research over the past several decades suggests that such systems are particularly well suited for use in regions of moderate to high seismic risk. This paper reviews the state of the art in seismic modeling, analysis, and design of HCW systems. Design methodologies are presented in both prescriptive and performance-based design formats and a discussion of alterative types of hybrid wall systems is provided.

1 February 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
BSBahram M. Shahrooz
Bahram M. Shahrooz
PFPatrick J. Fortney
Patrick J. Fortney
KHKent A. Harries
Kent A. Harries
Steel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 20-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.

1 September 2012 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
KHKent A. Harries
Kent A. Harries
BSBahram M. Shahrooz
Bahram M. Shahrooz
ASAmir Soltani
Amir Soltani
The introduction of steel reinforcing bars having yield strengths exceeding 517 MPa (75 ksi) and often approaching 827 MPa (120 ksi) may allow for significant economies to be realized, particularly when used in conjunction with high-strength concrete. One implication of the adoption of higher-strength reinforcing steel is that reinforcing bar stresses (and therefore strains and consequently crack widths) at service load levels are expected to be greater than when conventional bars [having a yield of 414 MPa (60 ksi)] are used. A study of flexural crack widths of beams reinforced with high-strength ASTM A1035 reinforcing steel is presented. Discussion focuses on the behavior at loads corresponding to longitudinal reinforcing bar stresses of 248, 414, and 496 MPa (36, 60, and 72 ksi), representing service load levels (i.e., 0.6fy) for steel having fy = 414,690, and 827 MPa (60, 100, and 120 ksi), respectively. Average measured crack widths obtained from a series of flexural beams having reinforcing ...

3 February 2006
Verified
Conference Paper
Closed access
PFPatrick J. Fortney
Patrick J. Fortney
BSBahram M. Shahrooz
Bahram M. Shahrooz
GRGian A. Rassati
Gian A. Rassati
Coupled core walls offer an efficient lateral load resisting system. Performance of coupled wall systems depends primarily on adequate stiffness and strength of coupling beams. Improvements in terms of constructability and performance are being explored as part of an ongoing study. A repairable or replaceable central "fuse" beam, where the inelastic deformations are concentrated, has been developed in an effort to protect the wall piers from local damage imparted by the coupling beams. A composite coupling beam utilizing an encased steel web plate is anticipated to facilitate construction of coupled core walls. Design methodologies for these systems were developed and evaluated. A summary of design methodologies along with measured responses is presented in this paper.

1 April 2001 in Progress in Structural Engineering and Materials
Verified
Journal Article
Closed access
PDF file
BSBahram M Shahrooz
Bahram M Shahrooz
BGBingnian Gong
Bingnian Gong
Gokhan TuncGokhan Tunc
Gokhan Tunc
JDJeremy T Deason
Jeremy T Deason

1 April 2018 in Engineering Structures
Verified
Journal Article
Closed access
MRMuhammad Mostafijur Rahman
Muhammad Mostafijur Rahman
SJSagar M. Jadhav
Sagar M. Jadhav
BSBahram M. Shahrooz
Bahram M. Shahrooz