11 June 2019 in Journal of Endocrinological Investigation
1 September 2020 in Oral Oncology
1 January 2020 in Gland Surgery
The iatrogenic injury of the recurrent laryngeal nerve (RLN), more clinically significant than those affecting the external branch of the superior laryngeal nerve (EBSLN), constitute one of the most feared perioperative complications of thyroid surgery and parathyroid glands, in terms of impact in clinical and economic-social costs. Moreover, these events rank among the leading reasons for medicolegal litigation of surgeons because of its attendant reduction in quality of life. The average incidence of RLN paralysis, permanent and temporary, after thyroidectomy is high and stands between 2.3% and 9.8% respectively. Given the elements described above, it is essential for the surgeon to adhere to a carefully standardized intraoperative technique that minimizes the possibility of RLN injuries. Intraoperative neuromonitoring (IONM) was introduced to reduce RLN injuries and for this reason, it achieved considerable success among endocrine surgeons. However, even today it is considered an adjunct device to the direct identification of the RLN. In this perspective, IONM of RLN constitutes an important aid, since it represents a reliable tool for the evaluation of functional neural integrity. Despite the ever-increasing diffusion of the IONM, prospective randomized studies are needed for further validation. The purpose of this work is to analyze scientific evidence to show that IONM in thyroid surgery is here to stay.
1 January 2019 in SiSli Etfal Hastanesi Tip Bulteni / The Medical Bulletin of Sisli Hospital
The Medical Bulletin of Sisli Etfal Hospital
23 August 2019 in Surgical and Radiologic Anatomy
1 March 2019 in Journal of Clinical & Translational Endocrinology
We evaluate the role of intraoperative neuromonitoring (IONM) in thyroidectomy performed for Graves' disease (GD) with an emphasis on recurrent laryngeal nerve (RLN) management and completeness of resection. The study is a retrospective series comprising 55 thyroidectomy (control group) versus 82 procedures with intermittent IONM (I-IONM) and 72 by means of continuous IONM (C-IONM). In the control group the laryngeal nerves have been identified by visualization solely. In the I-IONM group both vagal nerve (VN) and RLN have been localized and monitored during thyroid resection. C-IONM was achieved with a vagal stimulation probe. I-IONM group had shorter operating times (P = 0.032). RLN morbidity, meaning palsy rate, was 2.7% in the C-IONM group, 3.6% in I-IONM and 5.4% in the control group (P = 0.058). The proportion of complete procedures (total or near total resections) were significantly higher using monitoring technology (P = 0.049). Persistent positive serum TBII values were found in 25 (45%), 25 (30%) and 20 (27%) patients at 12 months in the control, I-IONM and C-IONM groups respectively (P = 0,04). IONM is an effective technology in GD patients.