The iatrogenic injury of the recurrent laryngeal nerve (RLN), more clinically significant than those affecting the external branch of the superior laryngeal nerve (EBSLN), constitute one of the most feared perioperative complications of thyroid surgery and parathyroid glands, in terms of impact in clinical and economic-social costs. Moreover, these events rank among the leading reasons for medicolegal litigation of surgeons because of its attendant reduction in quality of life. The average incidence of RLN paralysis, permanent and temporary, after thyroidectomy is high and stands between 2.3% and 9.8% respectively. Given the elements described above, it is essential for the surgeon to adhere to a carefully standardized intraoperative technique that minimizes the possibility of RLN injuries. Intraoperative neuromonitoring (IONM) was introduced to reduce RLN injuries and for this reason, it achieved considerable success among endocrine surgeons. However, even today it is considered an adjunct device to the direct identification of the RLN. In this perspective, IONM of RLN constitutes an important aid, since it represents a reliable tool for the evaluation of functional neural integrity. Despite the ever-increasing diffusion of the IONM, prospective randomized studies are needed for further validation. The purpose of this work is to analyze scientific evidence to show that IONM in thyroid surgery is here to stay.
This retrospective study aimed to describe, firstly, characteristics and outcomes of the intraoperative neural monitoring technology in the pediatric population, and secondarily the recurrent laryngeal nerve complication rate. Thirty-seven patients (age <18 years) operated on from 2015 to 2021 by conventional open thyroid surgery were included. Twenty-four (64.9%) total thyroidectomies and 13 (35.1%) lobectomies were performed. Seven central and six lateral lymph node dissections completed 13 bilateral procedures. Histology showed malignancy in 45.9% of the cases. The differences between the electromyographic profiles of endotracheal tubes or electrodes for continuous monitoring were not statistically significant. In our series of young patients, both adhesive (even in 4- or 5-year-olds) and embedded endotracheal tubes were used, while in patients 3 years old or younger, the use of a more invasive detection method with transcartilage placement recording electrodes was required. Overall, out of 61 total at-risk nerves, 5 (8.2%) recurrent laryngeal nerves were injured with consequent intraoperative loss of the signal; however, all these lesions were transient, restoring their normal functionality within 4 months from surgical procedure. To our knowledge, this is the first study of intraoperative neural monitoring management in a cohort of Italian pediatric patients.
19 August 2021 in Journal of Investigative Surgery
Introduction: Continuous intraoperative neural monitoring (C-IONM) is a promising technology used to decrease recurrent laryngeal nerve (RLN) damage during thyroid surgery. However, C-IONM use is limited due to its challenging application. C-IONM requires dissection of the carotid sheath and placement of an electrode around the vagus nerve (VN). In our study, we simultaneously stimulated and monitored the proximal RLN trans-tracheally using surface electrodes that were positioned solely on the endotracheal tube. Methods: We described the design, implementation, and testing of a pre-prototype, combined stimulating and recording endotracheal tube (SRET) that continually delivered current from tube edge, and tested the function of the RLN at the vocal cords (VC). The SRET was tested in vivo on 10 RLNs using 5 pigs as animal models. Results: The SRET was capable of the following, delivery of continuous trans-tracheal stimulation to the proximal RLN, continuous trans-tracheal stimulation-induced VC movement, and standard ipsilateral RLN biphasic waveforms with latency and amplitude; and recording evoked responses were recorded in the ipsilateral RLN. Conclusion: The pre-prototype SRET represents a possible advancement in technology because it simplified the C-IONM. Thus, the SRET provides a minimally invasive, alternative application to the C-IONM vagal nerve cuff electrodes.