Till Schürmann

Till Schürmann

Auto-generated profile, based on publicly available information

Till Schürmann

Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2008 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
SKS. Kriemler
S. Kriemler
CJC. Jansen
C. Jansen
ALA. Linka
A. Linka
AKA. Kessel-Schaefer
A. Kessel-Schaefer
MZMatthias Zehnder
Matthias Zehnder
HRH. P. Brunner-La Rocca
H. P. Brunner-La Rocca
The response of pulmonary artery pressure to high altitude has not been studied in children. It is also not known whether the individual response is hereditary. Therefore, the response of pulmonary artery pressure to high altitude was measured in pre-pubertal children in comparison to that in their biological fathers.Echocardiography was performed at 450 m and over 3 days at 3,450 m. Systolic pulmonary artery pressure was estimated from the pressure gradient of tricuspid regurgitation.The increase in pulmonary artery pressure in children was greater than that in adults at day 1 of high altitude (15.5±9.1versus7.9±6.4 mmHg), but returned to adult levels on day 2. The increase in pulmonary artery pressure from low to high altitude of each child correlated with that in the father.Pre-pubertal children transiently develop greater pulmonary hypertension than their fathers when exposed to high altitude. The individual response of pulmonary pressure to high altitude seems to be at least partly hereditary.

1 January 2023 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
ARAlexander Rau
Alexander Rau
JNJakob Neubauer
Jakob Neubauer
LTLaetitia Taleb
Laetitia Taleb
TSThomas Stein
Thomas Stein
TSTill Schuermann
Till Schuermann
JWJakob Weiss
Jakob Weiss
Rau A, et al. Korean J Radiol. 2023 Oct;24(10):1006-1016. https://doi.org/10.3348/kjr.2023.0211

21 October 2024 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
TSThomas Stein
Thomas Stein
CMConstantin von Zur Muhlen
Constantin von Zur Muhlen
Niklas VerlohNiklas Verloh
Niklas Verloh
TSTill Schüermann
Till Schüermann
TKTobias Krauss
Tobias Krauss
MHMuhammad Taha Hagar
Muhammad Taha Hagar
Evaluating small coronary stents with dual-source photon-counting computed tomography: effect of different scan modes on image quality and performance in a phantom - Diagnostic and Interventional Radiology

9 July 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TSTill Schürmann
Till Schürmann
UBUlrich Beschorner
Ulrich Beschorner
DWDirk Westermann
Dirk Westermann
TZThomas Zeller
Thomas Zeller
FBFabian Bamberg
Fabian Bamberg
ENElias Noory
Elias Noory
Digital variance angiography (DVA) exhibits promising prospects with respect to radiation exposure in digital subtraction angiography (DSA). This study aimed to determine the reduction of radiation dose in endovascular peripheral interventions (EPI) using DVA. The DVA imaging tool v6.0 (Kinepict Medical Imaging Tool, version 6.0.4, Kinepict Health Ltd., Budapest, Hungary) was utilized for patients undergoing EPI using digital angiography. EPI normal dose (EPI-ND) protocols were adapted from 1.20 to 0.81 µGy/frame to EPI low dose (EPI-LD) protocols using DVA-LD acquisitions with 0.36 µGy/frame and occasionally 0.24 µGy/frame based on specific examination requirements. The dose area product (DAP) was evaluated and contrast-to-noise ratio (CNR) was measured for each DSA acquisition. Evaluation included 370 EPI-ND and 62 EPI-LD using DVA-LD of three lower extremity regions (mean age: 73 ± 11 years, 67% male). LD protocols decreased median DAP of ND protocols significantly by 62.0% in pelvic, 53.8% in femoral and popliteal, and 59.4% in cruro-pedal regions, respectively (p < .005). DVA-LD increased median CNR significantly compared to DSA-LD (p < .001), and was equal to DSA-ND (p > .15). Image quality was enhanced by CNRDVA−LD/CNRDSA−ND ratio of 1.9 in pelvic, 2.4 in femoral and popliteal and in cruro-pedal regions. DVA reveals significant radiation dose reduction in lower extremity EPIs and enhances image contrast while decreasing noise.

11 January 2025 in European Journal of Radiology
Verified
Journal Article
Open access
TSTill Schürmann
Till Schürmann
TSThomas Stein
Thomas Stein
HUHorst Urbach
Horst Urbach
BSBastian E.A. Sajonz
Bastian E.A. Sajonz
FBFabian Bamberg
Fabian Bamberg
PRPeter C. Reinacher
Peter C. Reinacher
Directional deep brain stimulation (dDBS) relies on electrodes steering the stimulation field in a specific direction. Post implantation, however, the intended and real orientation of the lead frequently deviates e.g. due to torque of the electrode. The orientation is assessed by postoperative imaging such as C-arm cone-beam CT (CBCT) using 3D rotational fluoroscopy and multi-slice CT (MSCT). The objective is to determine the effect of different X-ray systems such as CBCT and MSCT, and scan acquisition parameters on effective radiation doses. We retrospectively investigated the dose area product (DAP) and dose length product (DLP) of patients who underwent both CBCT and MSCT after dDBS surgery. These metrics were then converted into the effective dose by established conversion coefficients. For CBCT, the feasible dose optimization by collimation was virtually assessed. Univariate analysis was performed to determine differences. Among 88 patients median effective dose was 0.20 ± 0.07 mSv in CBCT and 2.11 ± 0.33 mSv in MSCT (p < 0.001). The field of view (FOV) in CBCT can be collimated in craniocaudal orientation by 33.6 % and mediolaterally by 60.8 %. This optimized collimation implies an effective dose reduction of 76 % (p < 0.001). Comparison of the effective dose of MSCT vs. CBCT revealed a significant dose reduction by 90.3 % (p < 0.001), whereas optimal collimation by 97.7 % (p < 0.001). For assessment of dDBS orientation, CBCT had significantly lower radiation doses compared to MSCT. Optimized collimation in CBCT allows for a further substantial dose reduction. Moreover, the proposed approach is applicable on other neuroimaging procedures such as 3D visualization of treated intracranial aneurysm.