Thomas Stein

Dr. Thomas Stein

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Radiology
Verified
Journal Article
Closed access
MHMuhammad Taha Hagar
Muhammad Taha Hagar
MSMartin Soschynski
Martin Soschynski
RSRuben Saffar
Ruben Saffar
ARAlexander Rau
Alexander Rau
JTJana Taron
Jana Taron
TKTobias Krauss
Tobias Krauss
Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.

2 March 2023 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
TSThomas Stein
Thomas Stein
ARAlexander Rau
Alexander Rau
MRMaximilian Frederik Russe
Maximilian Frederik Russe
PAPhilipp Arnold
Philipp Arnold
SFSebastian Faby
Sebastian Faby
JWJakob Weiß
Jakob Weiß
Background Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today’s workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. Method The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms “Photon-Counting CT”, “Photon-Counting detector”, “spectral CT”, “Computed Tomography” as well as on the authors’ experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. Key Points: Citation Format

8 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TSThomas Stein
Thomas Stein
JTJana Taron
Jana Taron
NVNiklas Verloh
Niklas Verloh
MDMichael Doppler
Michael Doppler
ARAlexander Rau
Alexander Rau
JWJakob Weiss
Jakob Weiss
Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0–8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3–4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.

1 January 2023 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
ARAlexander Rau
Alexander Rau
JNJakob Neubauer
Jakob Neubauer
LTLaetitia Taleb
Laetitia Taleb
TSThomas Stein
Thomas Stein
TSTill Schuermann
Till Schuermann
JWJakob Weiss
Jakob Weiss
Rau A, et al. Korean J Radiol. 2023 Oct;24(10):1006-1016. https://doi.org/10.3348/kjr.2023.0211

21 October 2024 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
TSThomas Stein
Thomas Stein
CMConstantin von Zur Muhlen
Constantin von Zur Muhlen
Niklas VerlohNiklas Verloh
Niklas Verloh
TSTill Schüermann
Till Schüermann
TKTobias Krauss
Tobias Krauss
MHMuhammad Taha Hagar
Muhammad Taha Hagar
Evaluating small coronary stents with dual-source photon-counting computed tomography: effect of different scan modes on image quality and performance in a phantom - Diagnostic and Interventional Radiology

14 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MHMuhammad Taha Hagar
Muhammad Taha Hagar
MSMartin Soschynski
Martin Soschynski
MBMatthias Benndorf
Matthias Benndorf
TSThomas Stein
Thomas Stein
JTJana Taron
Jana Taron
TKTobias Krauss
Tobias Krauss
Background: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. Methods: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1—CAS-CT-derived CCTA + CAS-CT and Scenario 2—scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. Results: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8–5.3] mSv vs. 3.4 [1.5–5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. Conclusions: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.