19 May 2015 in Optics Express
NHNicolas Bourbeau Hébert
We have developed a frequency-comb spectrometer that records 35-nm (4 THz) spectra with 2-pm (250 MHz) spectral sampling and an absolute frequency accuracy of 2 kHz. We achieve a signal-to-noise ratio of ~400 in a measurement time of 8.2 s. The spectrometer is based on a commercial frequency comb decimated by a variable-length, low-finesse Fabry Pérot filter cavity to fully resolve the comb modes as imaged by a virtually imaged phased array (VIPA), diffraction grating and near-IR camera. By tuning the cavity length, spectra derived from all unique decimated combs are acquired and then interleaved to achieve frequency sampling at the comb repetition rate of 250 MHz. We have validated the performance of the spectrometer by comparison with a previous high-precision absorption measurement of H13C14N near 1543 nm. We find excellent agreement, with deviations from the expected line centers and widths of, at most, 1 pm (125 MHz) and 3 pm (360 MHz), respectively.
9 April 2025 in Physical Review Applied
28 August 2020 in Physical Review Applied
At low pressures, molecular spectra typically exhibit a large number of very narrow absorption features spread across a relatively wide spectral bandwidth. In order to obtain an accurate estimate of the line shapes, widths, and depths of these absorption features it is a requirement that one performs spectroscopy that is both densely spaced and high resolution across the entire spectral range. Here we demonstrate an approach that delivers on this need: it makes use of an optical frequency comb as the light source along with an optical filter cavity and a dispersive spectrometer to acquire high-resolution spectra with dense spectral sampling. The technique has the potential to acquire spectra with a resolution limit imposed solely by the frequency stability of the comb. As a proof of concept we measure the absorption spectrum of acetylene with a 7.86-MHz spectral spacing over 3.4-THz (25 nm) spectral range. This represents more than 430 000 individual spectral measurements, which are each individually free from the instrumentation broadening that limits conventional spectrometers. Using this spectrum, we extract the thermodynamic properties (temperature, pressure, and molecular density) of the gas sample with high accuracy and precision while simultaneously performing gas compositional analysis.
15 March 2016 in Optics Letters
NHNicolas Bourbeau Hébert
We demonstrate a simple interferometric technique to directly measure the complex optical transmittance over a large spectral range using a frequency-comb spectrometer based on a virtually imaged phased array. A Michelson interferometer encodes the phase deviations induced by a sample contained in one of its arms into an interferogram image. When combined with an additional image taken from each arm separately, along with a frequency-calibration image, this allows full reconstruction of the sample’s optical transfer function. We demonstrate the technique with a vapor cell containing , producing transmittance and phase spectra spanning 2.9 THz () with resolution.
23 September 2019 in Physical Review Applied
We report on the use of direct frequency comb spectroscopy to accurately measure the concentrations of and isotopologs in a gas sample. We demonstrate an accuracy of 0.5% and 12% for concentration measurements of and , respectively, with the measured isotopic ratio in excellent agreement with that expected from their natural abundances. The precision of the concentration measurements is also high, at 0.03% and 1.24% for and , respectively. The measurement technique is verified to be highly linear for concentrations ranging over 3 orders of magnitude. Direct frequency comb spectroscopy can be applied to numerous molecular species, and is therefore a promising technique for measurements in environmental monitoring and biomedical sciences.
29 May 2018 in Physical Review Applied
Real-time and accurate measurements of gas properties are highly desirable for numerous real-world applications. Here, we use an optical-frequency comb to demonstrate absolute number-density and temperature measurements of a sample gas with state-of-the-art precision and accuracy. The technique is demonstrated by measuring the number density of with an accuracy of better than 1% and a precision of 0.04% in a measurement and analysis cycle of less than 1 s. This technique is transferable to numerous molecular species, thus offering an avenue for near-universal gas concentration measurements.