30 March 2017 in Optics Express
We present a dual-comb spectrometer based on two passively mode-locked waveguide lasers integrated in a single Er-doped ZBLAN chip. This original design yields two free-running frequency combs having a high level of mutual stability. We developed in parallel a self-correction algorithm that compensates residual relative fluctuations and yields mode-resolved spectra without the help of any reference laser or control system. Fluctuations are extracted directly from the interferograms using the concept of ambiguity function, which leads to a significant simplification of the instrument that will greatly ease its widespread adoption and commercial deployment. Comparison with a correction algorithm relying on a single-frequency laser indicates discrepancies of only 50 attoseconds on optical timings. The capacities of this instrument are finally demonstrated with the acquisition of a high-resolution molecular spectrum covering 20 nm. This new chip-based multi-laser platform is ideal for the development of high-repetition-rate, compact and fieldable comb spectrometers in the near- and mid-infrared.
24 May 2019 in IEEE Journal of Quantum Electronics
Self-sufficient correction algorithms have recently been developed to estimate and compensate the relative frequency noise between two free-running frequency combs using only their dual-comb interferograms (IGMs). However, such algorithms are limited by the relatively low observation rate of the frequency noise, equal to the IGM repetition rate. In this paper, we analyze the effectiveness of estimation methods based on the cross-correlation function and the ambiguity function. We derive estimators and obtain their theoretical variances as a function of the IGMs’ measurable parameters to later establish criteria that verify the success rate of each method for the correction and coherent averaging of successive IGMs. Finally, we present different cases of both real and simulated dual-comb systems and assess their compatibility with these estimation methods.
2 July 2025 in Nature Communications
Atomic clocks are at the leading edge of accuracy and precision and are essential for synchronisation of distributed critical infrastructure, position, navigation and timing, and scientific applications. There has been significant improvements in the performance of atomic clocks with the shift from microwave to optical frequency transitions. However, this performance increase has come at the cost of size, complexity and fragility, which has confined optical clocks to laboratories. Here we report on a recent international collaboration where three emerging optical clocks, each based on different operating principles, were trialled at sea. These clocks demonstrated world-class performance and reliability by providing stable frequency outputs in optical, microwave and radio-frequency domains over three weeks of unsupervised naval operation.
11 April 2018 in Optics Letters
VMVincent Michaud-Belleau
We characterize the frequency noise performance of a free-running dual-comb source based on an erbium-doped glass chip running two adjacent mode-locked waveguide lasers. This compact laser platform, contained only in a 1.2 L volume, rejects common-mode environmental noise by 20 dB thanks to the proximity of the two laser cavities. Furthermore, it displays a remarkably low mutual frequency noise floor around , which is enabled by its large-mode-area waveguides and low Kerr nonlinearity. As a result, it reaches a free-running mutual coherence time of 1 s since mode-resolved dual-comb spectra are generated even on this time scale. This design greatly simplifies dual-comb interferometers by enabling mode-resolved measurements without any phase lock.
1 November 2021 in Applied Soil Ecology
9 April 2025 in Physical Review Applied