Jiangtao Li

Jiangtao Li

Auto-generated profile, based on publicly available information

Jiangtao Li

School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, People’s Republic of China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in High Voltage
Verified
Journal Article
Open access
PDF file
ZZZheng Zhao
Zheng Zhao
JLJiangtao Li
Jiangtao Li
Repetitively pulsed gas volume and dielectric surface discharges have gained growing attention because of peculiar and exciting physics phenomena, high efficiency, high reactivity, and potential to obtain conventionally unachievable plasma properties. Nevertheless, incomplete understanding of fundamental mechanisms renders the repetitively pulsed discharge far less predictable and controllable, where the inherent memory effect and the discharge mode transition are universal challenges. In this topical review, the authors will explore the macroscopic characteristics of the gas gap breakdown and the surface flashover, state‐of‐the‐art mechanisms and dominant agents of discharge memory effects, operation regimes and transitions of the discharge mode, and how waveform parameters affect the pulsed discharge properties. Challenges and potential approaches for further understanding the memory effect and the discharge mode transition in the repetitively pulsed discharge are discussed.

5 June 2015 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
JLJiangtao Li
Jiangtao Li
XZXu Zhong
Xu Zhong
JLJianhao Li
Jianhao Li
ZLZheng Liang
Zheng Liang
WCWenzhong Chen
Wenzhong Chen
TLTao Li
Tao Li
High-voltage, nanosecond, high-repetitive-frequency, and portable pulse generators are always required in many fields. Avalanche transistor-based Marx circuits have been widely studied to generate pulses satisfying the above requirements. However, the basic topology of an avalanche transistor-based circuit, configuration of circuit parameters, and optimal working performance (including output impedance matching) were still scarcely discussed. In this paper, the detailed process of analyzing and designing a compact Marx generator using avalanche transistors was described. Based on the conventional principles of avalanche transistors and Marx circuit, a list of useful and interesting conclusions was discovered by experiment. An example with specific parameter requirements was utilized for the clearness of illustration. The 12 cm × 4 cm Marx circuit could finally generate pulses with a 2.5-kV amplitude, 6.0-ns width, 10-kHz repetitive frequency, lower than a 100-ps jitter and ~125-kW maximum peak output power on a matched 50-Ω resistive load. The pulse amplitude could be adjusted from 1.5 to 2.5 kV and the pulse width could also be broadened. This paper may help to provide a reference to similar methods of producing high-voltage, nanosecond, and high-repetitive-frequency pulses.

22 August 2019 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LLLongjie Li
Longjie Li
ZZZheng Zhao
Zheng Zhao
YLYuhao Liu
Yuhao Liu
CLChenjie Li
Chenjie Li
JRJiarui Ren
Jiarui Ren
JLJiangtao Li
Jiangtao Li
Gas-discharge closing switches are the key component of a pulsed power supply. Repetitive gas-discharge closing switches are still the preferred scheme for high-power repetitive pulse power generators in many applications, but their repetition performance depends on the recovery time of the gas insulation medium. This article reviews the existing repetitive gas-discharge closing switches. The basic structure and working principle of each switch are briefly introduced. This article focuses on advances in the study of the factors that impact the recovery characteristics of gaseous insulation in switches. It also presents a survey of methods to improve the performance of gas switches' repetition rate.

1 March 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JLJiangtao Li
Jiangtao Li
ZZZheng Zhao
Zheng Zhao
YSYi Sun
Yi Sun
YLYuhao Liu
Yuhao Liu
ZRZiyuan Ren
Ziyuan Ren
MZMinjun Zheng
Minjun Zheng
Numerous applications driven by pulsed voltage require pulses to be with high amplitude, high repetitive frequency, and narrow width, which could be satisfied by utilizing avalanche transistors. The output improvement is severely limited by power capacities of transistors. Pulse combining is an effective approach to increase the output amplitude while still adopting conventional pulse generating modules. However, there are drawbacks in traditional topologies including the saturation tendency of combining efficiency and waveform oscillation. In this paper, a hybrid pulse combining topology was adopted utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer. The factors affecting the combining efficiency were determined including the output time synchronization of Marx circuits, and the quantity and position of magnetic cores. The numbers of the parallel modules and the stages were determined by the output characteristics of each combining method. Experimental results illustrated the ability of generating pulses with 2-14 kV amplitude, 7-11 ns width, and a maximum 10 kHz repetitive rate on a matched 50-300 Ω resistive load. The hybrid topology would be a convinced pulse combining method for similar nanosecond pulse generators based on the solid-state switches.

15 August 2014 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JLJiangtao Li
Jiangtao Li
ZZZhijie Zhao
Zhijie Zhao
BSBin Shu
Bin Shu
XHXiaopeng Han
Xiaopeng Han
XMXueliang Ma
Xueliang Ma
ZLZheng Liang
Zheng Liang
It is very attractive to replace the traditional power cables into high-temperature superconducting (HTS) cables for electricity transmission to metropolitan areas with the advantages of high capacity and low losses. However, these advantages only present when the conductors are kept in certain low temperature range. When a fault occurs, the HTS cable may quench and the resistivity of the conductor will increase rapidly which will result in the reduction of transmission capacity, increase of the power loss and even electrical insulation breakdown. Therefore, it is necessary to investigate the level of over current and overvoltage. In this paper, an accurate model for a 1-km-long 110 kV HTS cable is given and a simple simulation model for HTS cable is built up using EMTP-ATP program. Single-phase short-circuit fault and electrical insulation breakdown fault are considered to investigate the overvoltage and over current level of the HTS cable. The simulation results may provide instructive guide for the protection systems for HTS cables.

1 September 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JLJiang-Tao Li
Jiang-Tao Li
XZXu Zhong
Xu Zhong
HCHui Cao
Hui Cao
ZZZheng Zhao
Zheng Zhao
JXJing Xue
Jing Xue
YWYa-Nan Wang
Ya-Nan Wang
Avalanche transistors have been widely studied and used in nanosecond high voltage pulse generations. However, output power improvement is always limited by the low thermal capacities of avalanche transistors, especially under high repetitive working frequency. Parallel stacked transistors can effectively improve the output current but the controlling of trigger and output synchronism has always been a hard and complex work. In this paper, a novel stereo-symmetrical nanosecond pulsed power generator with high reliability was developed. By analyzing and testing the special performances of the combined Marx circuits, numbers of meaningful conclusions on the pulse amplitude, pulse back edge, and output impedance were drawn. The combining synchronism of the generator was confirmed excellent and lower conducting current through the transistors was realized. Experimental results showed that, on a 50 Ω resistive load, pulses with 1.5–5.2 kV amplitude and 5.3–14.0 ns width could be flexibly generated by adjusting the number of combined modules, the supply voltage, and the module type.