Guangliang Wu

Guangliang Wu

Auto-generated profile, based on publicly available information

Guangliang Wu

State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences (Beijing), Beijing 100083, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JZJian-Ming Zhu
Jian-Ming Zhu
GWGuangliang Wu
Guangliang Wu
XWXiangli Wang
Xiangli Wang
Guilin HanGuilin Han
Guilin Han
LZLixin Zhang
Lixin Zhang
Chromium (Cr) isotopes have been used to trace pollution processes and reconstruct paleo-redox conditions. However, the precise determination of Cr isotopes is still challenged by difficulties in purifying Cr from samples with low Cr and high matrix content. Here, we developed an improved, flexible and easily operated three-step chromatographic procedure to separate Cr from high-matrix samples. A continuous, two-stage column (Step I) filled with 2 mL cation resin AG50W-X8 (200–400 m) and 2 mL anion resin AG1-X8 resin (100–200 m), followed by Step II, with 1 mL of AG1-X8 resin (200–400 m), was used to remove at least 99% of Ca, Fe, and Ti, and >90% of V and most other matrix elements, even for samples with Fe/Cr ≈ 6000 and Ti/Cr ≈ 1000. The recovery of Cr in both Step I and Step II can reach nearly 100%. Step III utilizes 2 mL AG1-X8 (100–200 m) combined with an (NH4)2S2O8 oxidant to remove residual matrix elements and achieve high-purity Cr. The total yield of Cr through our three-step procedure is greater than 80% even for low-Cr (2.6 μg kg−1) samples. A relatively small sample amount (300–600 ng Cr) is enough to achieve high precision Cr isotope measurement due to a low procedural blank (<1 ng). Chromium isotopes in geological reference materials (BHVO-2, JDo-1, JP-1, etc.) were measured on a Neptune Plus MC-ICP-MS. The long-term external precision is 0.06‰ (2SD), and the δ53Cr values are in great agreement with previously reported values. The δ53Cr of the upper continental crust is estimated to be −0.10 ± 0.10‰ using a suite of granite, diamictite, sediment and loess samples. Both plants and human hair are ∼0.1‰ heavier than the upper continental crust. Tests show that our improved purification procedure is applicable to various geological and environmental samples.

28 May 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
GWGuangliang Wu
Guangliang Wu
JZJian-Ming Zhu
Jian-Ming Zhu
XWXiangli Wang
Xiangli Wang
Guilin HanGuilin Han
Guilin Han
DTDecan Tan
Decan Tan
SWShui-Jiong Wang
Shui-Jiong Wang
Nickel (Ni) isotopes have been developed as a potential biosignature and proxy for tracing the occurrence of the Great Oxidation Event. However, the precise measurement of Ni isotopes is still hindered by the costly operation, complicated procedures and/or high procedural blanks of the chemical purification schemes. Here, a novel purification scheme, utilizing only dimethylglyoxime (DMG) and acetone as organic reagents, is proposed to separate Ni from samples through a four-step procedure with five chromatographic columns. Steps I, II and III are designed to effectively eliminate major matrix elements, including 99% Fe, Ca, Ti, and Al, 85% Mn, 55% K, even for samples with [Ca]/[Ni] ≈ 4600 and [Mg]/[Ni] ≈ 1900. Step IV utilizes the formation of Ni(DMG)2 complexes in an aqueous medium containing 0.5 M HCl, 95% acetone and 0.1 M DMG, which can remove residual elements such as 45% K; this step avoids the use of Ni-specific resin, which requires careful pH tuning. Steps III and I can be repeated to obtain high-purity Ni. The Ni yield through these four steps is greater than 92%, with a maximum loss of ∼8% occurring in Step II for low-Ni samples. The total procedural blank is 0.4 to 1.2 ng. When double spiking (61Ni–60Ni) is used to correct for instrument mass bias and purification-related isotope fractionation, small sample sizes (600–800 ng) are sufficient for achieving high-precision Ni isotope determination. Nickel isotopes for standards such as SRM 986 and geological reference materials (GRMs) such as BHVO-2, NOD-P-1, and NOD-A were determined on a Nu Plasma III MC-ICP-MS. The long-term reproducibility is 0.05‰ (2SD, n = 134) for pure solution and 0.06‰ (2SD, n = 18) for GRMs, and the average δ60Ni values are in excellent agreement with previous studies. These results show that our new purification method can be applied to various samples. Using this new method, we measured a set of granite, sediment, diamictite and loess samples and preliminarily constrained the δ60Ni of the upper continental crust to be 0.11 ± 0.14‰ (2SD, n = 17).

17 March 2020 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
WLWeihan Li
Weihan Li
JZJian‐Ming Zhu
Jian‐Ming Zhu
DTDecan Tan
Decan Tan
Guilin HanGuilin Han
Guilin Han
ZZZhouqiao Zhao
Zhouqiao Zhao
GWGuangliang Wu
Guangliang Wu