Jian-Ming Zhu

Jian-Ming Zhu

Auto-generated profile, based on publicly available information

Jian-Ming Zhu

State Key Laboratory of Geological Processes and Mineral Resources

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
DTDecan Tan
Decan Tan
JZJian-Ming Zhu
Jian-Ming Zhu
XWXiangli Wang
Xiangli Wang
Guilin HanGuilin Han
Guilin Han
ZLZhuo Lu
Zhuo Lu
WXWenpo Xu
Wenpo Xu
With new advancements in MC-ICP-MS technology, small Cd isotope fractionations in geological processes have attracted more interest in recent years. However, challenges remain in obtaining high-precision Cd isotope data for geological samples with low Cd concentrations and complex matrices. By an improved Cd purification and cleaning resin scheme for low-Cd samples using AGMP-1M resin with >90% Cd recovery, the ratios of trace elements Sn, Mo, Zr, etc. to Cd in the samples, which could potentially jeopardize the accuracy and precision of Cd isotope analysis under a high-sensitivity setup, were less than 0.001 after purification, and the total procedure blank is ≤0.1 ng. Hence, a sample containing 20–30 ng Cd can be employed for purification and subsequent isotope measurement. Cadmium isotope fractionation (expressed in δ114/110Cd relative to NIST 3108) during column separation and instrument mass bias was corrected for by a 111Cd–113Cd double spike. NIST 3108 was determined at a concentration of 5–25 ng mL−1 on a Neptune Plus (112Cd signal intensity: ∼640 V ppm−1) and 25–50 ng mL−1 on a Nu plasma III (112Cd signal intensity:∼280 V ppm−1) MC-ICP-MS equipped with an Aridus II/III desolvator for more than one year, with a total external analytical precision of 0.034‰ (2SD, n = 181). NIST SRM 2711a, NOD-P-1 and GSS-1 were measured at 5, 10, 20, 25 and 50 ng mL−1 levels to be 0.532 ± 0.038‰, 0.133 ± 0.038‰ and 0.098 ± 0.027‰, respectively, indicating that good accuracy and precision of Cd isotope analysis can be achieved with an injecting sample size as low as 5 ng Cd. Our method can be reliably applied to various geological reference materials (GRMs). The δ114/110Cd values of GRMs with relatively high and low Cd concentrations are consistent with previous studies: NOD-A-1 (0.124 ± 0.067‰), GSD-11 (−0.274 ± 0.037‰) and BCR-2 (−0.030 ± 0.063‰). SGR-1b (0.069 ± 0.049‰), GSH-1 (−0.337 ± 0.077‰) and others are reported for the first time in this paper. The δ114/110Cd in basalt and stream sediments is relatively homogeneous and overlaps with that of the bulk silicate earth (BSE). The δ114/110Cd in shale and soils varies greatly from −0.694 to 0.532‰. Human hair and other animal organs are enriched in light isotopes relative to BSE, whereas terrestrial plants are enriched in heavy isotopes.

1 June 2017 in Environmental Pollution
Verified
Journal Article
Closed access
HQHai-Bo Qin
Hai-Bo Qin
JZJian-Ming Zhu
Jian-Ming Zhu
ZLZhi-Qing Lin
Zhi-Qing Lin
WXWen-Po Xu
Wen-Po Xu
DTDe-Can Tan
De-Can Tan
YTYoshio Takahashi
Yoshio Takahashi

12 January 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
SWShui-Jiong Wang
Shui-Jiong Wang
WWWenzhong Wang
Wenzhong Wang
JZJian-Ming Zhu
Jian-Ming Zhu
ZWZhongqing Wu
Zhongqing Wu
JLJingao Liu
Jingao Liu
WLWeihan Li
Weihan Li
Earth’s habitability is closely tied to its late-stage accretion, during which impactors delivered the majority of life-essential volatiles. However, the nature of these final building blocks remains poorly constrained. Nickel (Ni) can be a useful tracer in characterizing this accretion as most Ni in the bulk silicate Earth (BSE) comes from the late-stage impactors. Here, we apply Ni stable isotope analysis to a large number of meteorites and terrestrial rocks, and find that the BSE has a lighter Ni isotopic composition compared to chondrites. Using first-principles calculations based on density functional theory, we show that core-mantle differentiation cannot produce the observed light Ni isotopic composition of the BSE. Rather, the sub-chondritic Ni isotopic signature was established during Earth’s late-stage accretion, probably through the Moon-forming giant impact. We propose that a highly reduced sulfide-rich, Mercury-like body, whose mantle is characterized by light Ni isotopic composition, collided with and merged into the proto-Earth during the Moon-forming giant impact, producing the sub-chondritic Ni isotopic signature of the BSE, while delivering sulfur and probably other volatiles to the Earth.

1 March 2020 in Geochimica et Cosmochimica Acta
Verified
Journal Article
Closed access
WXWenpo Xu
Wenpo Xu
JZJian-Ming Zhu
Jian-Ming Zhu
TJThomas M. Johnson
Thomas M. Johnson
XWXiangli Wang
Xiangli Wang
ZLZhi-Qing Lin
Zhi-Qing Lin
HQHaibo Qin
Haibo Qin

28 March 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JZJian-Ming Zhu
Jian-Ming Zhu
GWGuangliang Wu
Guangliang Wu
XWXiangli Wang
Xiangli Wang
Guilin HanGuilin Han
Guilin Han
LZLixin Zhang
Lixin Zhang
Chromium (Cr) isotopes have been used to trace pollution processes and reconstruct paleo-redox conditions. However, the precise determination of Cr isotopes is still challenged by difficulties in purifying Cr from samples with low Cr and high matrix content. Here, we developed an improved, flexible and easily operated three-step chromatographic procedure to separate Cr from high-matrix samples. A continuous, two-stage column (Step I) filled with 2 mL cation resin AG50W-X8 (200–400 m) and 2 mL anion resin AG1-X8 resin (100–200 m), followed by Step II, with 1 mL of AG1-X8 resin (200–400 m), was used to remove at least 99% of Ca, Fe, and Ti, and >90% of V and most other matrix elements, even for samples with Fe/Cr ≈ 6000 and Ti/Cr ≈ 1000. The recovery of Cr in both Step I and Step II can reach nearly 100%. Step III utilizes 2 mL AG1-X8 (100–200 m) combined with an (NH4)2S2O8 oxidant to remove residual matrix elements and achieve high-purity Cr. The total yield of Cr through our three-step procedure is greater than 80% even for low-Cr (2.6 μg kg−1) samples. A relatively small sample amount (300–600 ng Cr) is enough to achieve high precision Cr isotope measurement due to a low procedural blank (<1 ng). Chromium isotopes in geological reference materials (BHVO-2, JDo-1, JP-1, etc.) were measured on a Neptune Plus MC-ICP-MS. The long-term external precision is 0.06‰ (2SD), and the δ53Cr values are in great agreement with previously reported values. The δ53Cr of the upper continental crust is estimated to be −0.10 ± 0.10‰ using a suite of granite, diamictite, sediment and loess samples. Both plants and human hair are ∼0.1‰ heavier than the upper continental crust. Tests show that our improved purification procedure is applicable to various geological and environmental samples.

28 May 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
GWGuangliang Wu
Guangliang Wu
JZJian-Ming Zhu
Jian-Ming Zhu
XWXiangli Wang
Xiangli Wang
Guilin HanGuilin Han
Guilin Han
DTDecan Tan
Decan Tan
SWShui-Jiong Wang
Shui-Jiong Wang
Nickel (Ni) isotopes have been developed as a potential biosignature and proxy for tracing the occurrence of the Great Oxidation Event. However, the precise measurement of Ni isotopes is still hindered by the costly operation, complicated procedures and/or high procedural blanks of the chemical purification schemes. Here, a novel purification scheme, utilizing only dimethylglyoxime (DMG) and acetone as organic reagents, is proposed to separate Ni from samples through a four-step procedure with five chromatographic columns. Steps I, II and III are designed to effectively eliminate major matrix elements, including 99% Fe, Ca, Ti, and Al, 85% Mn, 55% K, even for samples with [Ca]/[Ni] ≈ 4600 and [Mg]/[Ni] ≈ 1900. Step IV utilizes the formation of Ni(DMG)2 complexes in an aqueous medium containing 0.5 M HCl, 95% acetone and 0.1 M DMG, which can remove residual elements such as 45% K; this step avoids the use of Ni-specific resin, which requires careful pH tuning. Steps III and I can be repeated to obtain high-purity Ni. The Ni yield through these four steps is greater than 92%, with a maximum loss of ∼8% occurring in Step II for low-Ni samples. The total procedural blank is 0.4 to 1.2 ng. When double spiking (61Ni–60Ni) is used to correct for instrument mass bias and purification-related isotope fractionation, small sample sizes (600–800 ng) are sufficient for achieving high-precision Ni isotope determination. Nickel isotopes for standards such as SRM 986 and geological reference materials (GRMs) such as BHVO-2, NOD-P-1, and NOD-A were determined on a Nu Plasma III MC-ICP-MS. The long-term reproducibility is 0.05‰ (2SD, n = 134) for pure solution and 0.06‰ (2SD, n = 18) for GRMs, and the average δ60Ni values are in excellent agreement with previous studies. These results show that our new purification method can be applied to various samples. Using this new method, we measured a set of granite, sediment, diamictite and loess samples and preliminarily constrained the δ60Ni of the upper continental crust to be 0.11 ± 0.14‰ (2SD, n = 17).